Title: Backup Airways
1Backup Airways
New Hampshire Division of Fire Standards
Training and Emergency Medical Services 2011
2Know Your Options!!! Dont hesitate to use them!
3Purpose
- It is vital that the prehospital crew be
confident and comfortable with the rescue airways
approved for their level of licensure. - During this module you will review and practice
the back up airways for your level of licensure.
4Purpose
- Review Backup Airway Devices (Rescue Airways)
- BVM
- LMA
- King-LT-D
- Combitube
5What do we do when we have a difficult airway?
6The Basics
- Position
- OPA
- BVM
- Suction
- Most difficult airways will still be manageable
using basic airway maneuvers!
7The Need for Oxygen
- 0 1 minute cardiac irritability
- 0 4 minutes brain damage not likely
- 4 6 minutes brain damage possible
- 6 10 minutes brain damage very likely
- gt 10 minutes irreversible brain damage
8Oxygen and Carbon Dioxide Exchange
- Oxygen-rich air is inhaled to alveoli
- O2 exchanged at alveolocapillary level
- Perfusion to capillary beds
- O2/CO2 exchange at cellular level
- Perfusion from capillary beds
- CO2 exhanged at alveolocapillary level
- CO2 exhaled
9Assessment of Respiration
- Patients level of consciousness
- Respiration quality
- Pulse quality
- Respiratory rate
- Pulse rate
- SPO2
- EtCO2
- Blood pressure
- Glasgow coma score
10Every TRUE life saving intervention performed by
EMS reverses one or more failing components of
respiration
11BVM is the most essential intervention in RSI
12Inadequate Breathing
- Fast or slow rate
- Irregular rhythm
- Abnormal lung sounds
- Reduced tidal volume
- Use of accessory muscles
- Cool, pale, diaphoretic, cyanotic skin
13Head Tilt-Chin Lift
- One hand on the forehead
- Apply backward pressure
- Tips of fingers under mandible
- Lift the chin
14Jaw-Thrust Maneuver
- Place fingers behind the angle of the jaw
- Use thumbs to open mouth
15Look, Listen, and Feel
16Basic Airway Adjuncts
- Oropharyngeals
- Keeps tongue from blocking oropharynx
- Eases suctioning
- Used with BVM
- Patients without gag reflex
- Nasopharyngeals
- Maintains patency of oropharynx
- Patients with gag reflex
- Should not be used with head trauma
17Oxygen
- Nonrebreathing mask
- Provides up to 90 oxygen
- Used at 10 to 15 L/min
- Nasal cannula
- Provides 24 to 44 oxygen
- Used at 1 to 6 L/min
18Oxygen
- Nasal cannula
- 24-40 at 1-6 liters
- Non-rebreather mask
- Up to 90 at 15 liters
- BVM
- 21 atmosphere
- Up to 100 at 15 liters with reservoir
19Artificial Ventilation
- Mouth to mask
- BVM one person
- BVM two person
20Ventilation Rates
- Adults 8 - 10 breaths per minute
- Approximately one breath every 6 8 seconds
- Pediatric 12 20 breaths per minute
- Approximately one breath every 3 6 seconds
21Bag Valve Mask
- Delivers gt 90 oxygen
- Requires practice and proficiency
- Use with airway adjuncts and/or advanced airways
22BVM-Problems encountered
- Inattentiveness
- Poor mask seal poor ventilatory ability
- Varying ventilatory rates
- Varying expiration rates
- Varying tidal volumes
- Often excessive airway pressure
- Often hyper-ventilation
Mastering the BVM overcomes these obstacles!
23BVM One person
- Insert an oral/nasal airway
- Seal mask by placing the apex over the bridge of
the nose and lower portion of the mask over the
mouth and upper chin. - Make a C with your index finger and thumb
around the mask. - Maintain the airway with your middle, ring and
little finger, creating a E, under the jaw to
maintain the chin lift. - Squeeze the bag with your other hand slowly at a
rate of one breath every 68 seconds. - Monitoring SpO2
24BVM Two Person
- Insert oral/nasal airway
- First provider hold the bag portion of the BVM
with both hands. - Second provider seals the mask with apex over the
bridge of the nose and base at the upper chin. - Using two hands the second provider places
his/her thumbs over the top half of the mask
index and middle finger over bottom half ring
and little finger under jaw. - Second provider also maintains chin-lift
- First provider squeezes bag every 68 seconds
- Monitoring SpO2.
25Adequate Ventilation
- Equal chest rise and fall
- Appropriate rate
- Heart rate returns to normal
26Inadequate Ventilation
- Minimal or no chest rise
- Ventilating too fast or too slow
- Heart rate does not return to normal
27Asthma and COPD
- These patients complicate the traditional RSI
approach due to the difficulty encountered when
mask ventilating - Alveolar hyperinflation secondary to underlying
pathophysiology must be considered and adequate
passive ventilation time must be ensured - Tidal volumes should be reduced, initially, to
reduce likelihood of barotrauma and air trapping
28Gastric Distention
- Air fills the stomach from too forceful or too
frequent ventilations - Airway may be blocked and ventilations are
re-routed to stomach - Decreases lung capacity
- May cause patient to vomit
29Airway Obstructions
- Tongue
- Vomit
- Blood, clots, traumatized tissue
- Swelling
- Foreign objects
30Recognizing an Obstruction
- Partial or complete?
- Can patient speak? Cough?
- If unconscious, deliver artificial ventilation
- Does air go in? Does the chest rise?
31Removing an Obstruction
- Heimlich maneuver
- Suction
- Magills (paramedics)
32Suctioning
- Turn on unit and ensure proper suctioning
pressure (300 mmHg) - Select proper tip and measure
- Insert with suction off
- Suction on the way out
- Suction for no more than 15 seconds
33Continuous Positive Airway Pressure (CPAP)
- Is the patient a candidate for CPAP?
34CPAP Indications
- Any patient in respiratory distress associated
with CHF with any of the below obvious signs and
symptoms or a history of CHF - Bibasilar or diffuse rales
- Respiratory rate greater than 25
- Pulse oximetry below 92
- Retractions or accessory muscle use
- Abnormal capnography (rate, waveform, CO2 levels)
35RSI Indication
- Immediate severe airway compromise in the context
of trauma, drug overdose, status epilepticus,
etc. where respiratory arrest in imminent.
36Always have a back-up plan.
- Plans A, B, and C
- Know the answers before you begin
37Plan A (ALTERNATIVES)
- Different
- Size of blade
- Type of blade
- Miller
- Macintosh
- Specialty
- Position (patient provider)
- Hockey stick bend in ETT or Directional tip ETT
- Remove the stylette as you pass through the cords
- BURP (aka ELM)
- Gum Elastic Bougie
- 2-person technique
- cowboy or skyhook
- Have someone else try
38Viewmax Scope
- Easy of use
- Can be used like a Mac or Miller
- Should improve your view by one grade
39BURP a.k.a. External Laryngeal Manipulation
- Backward, Upward, Rightward Pressure
manipulation of the trachea - 90 of the time the best view will be obtained by
pressing over the thyroid cartilage
Differs from the Sellick Maneuver
40Plan B (BVM and BACK UP Airways)
- Can you ventilate with a BVM?
- (Consider two NPAs and an OPA, Cricoid
pressure w/ gentle ventilation) - KINGLT-D
- Combitube
- LMA
41King-LT-D
42King LT-D
43(No Transcript)
44(No Transcript)
45(No Transcript)
46(No Transcript)
47(No Transcript)
48(No Transcript)
49(No Transcript)
50(No Transcript)
51(No Transcript)
52(No Transcript)
53(No Transcript)
54(No Transcript)
55(No Transcript)
56(No Transcript)
57(No Transcript)
58(No Transcript)
59(No Transcript)
60(No Transcript)
61(No Transcript)
62Combitube
63CombiTube
64Insertion Technique
- Tongue-Jaw Lift
- Anatomical Insertion
- Black rings will lie between teeth or alveolar
ridges - Bending the tip prior to use may ease insertion
65CombiTube
- Inflate Blue Balloon
- Inflate White Balloon
- The CombiTube may reposition as the oropharyngeal
is inflated.
66Esophageal Placement
- Ventilate Blue Tube
- Visualize
- Auscultate
- EtCO2
67Tracheal Placement
- Ventilate Clear Tube
- Visualize
- Auscultate
- EtCO2
68Laryngeal Mask AirLMA
69LMA
- The LMA was invented by Dr. Archie Brain at the
London Hospital in Whitechapel in 1981 - The LMA consists of two parts
- The mask
- The tube
- The LMA has proven to be a very effective
management tool for the airway
70Introduction continued
- The LMA design
- Provides an oval seal around the laryngeal
inlet once the LMA is inserted and the cuff
inflated. - Once inserted, it lies at the crossroads of the
digestive and respiratory tracts.
71Indications
- Situations involving a difficult mask (BVM) fit.
- May be used as a back-up device where
endotracheal intubation is not successful. - May be used as a second-last-ditch airway where
a surgical airway is the only remaining option.
72Contraindications
- Greater than 14 to 16 weeks pregnant
- Patients with multiple or massive injury
- Massive thoracic injury
- Massive maxillofacial trauma
- Patients at risk of aspiration
- NOTE Not all contraindications are absolute
73Complications
- Throat soreness
- Dryness of the throat and/or mucosa
- Complications due to improper placement vary
based on the nature of the placement
74Equipment for LMA Insertion
- Body Substance Isolation equipment
- Appropriate size LMA
- Syringe with appropriate volume for LMA cuff
inflation - Water soluble lubricant
- Ventilation equipment
- Stethoscope
- Tape or other device(s) to secure LMA
75Preparation
- Step 1 Size selection
- Step 2 Examination of the LMA
- Step 3 Check deflation and inflation of the
cuff - Step 4 Lubrication of the LMA
- Step 5 Position the Airway
76Step 1 Size Selection
- Verify that the size of the LMA is correct for
the patient - Recommended Size guidelines
- Size 1 under 5 kg
- Size 1.5 5 to 10 kg
- Size 2 10 to 20 kg
- Size 2.5 20 to 30 kg
- Size 3 30 kg to small adult
- Size 4 adult
- Size 5 Large adult/poor seal with size 4
77Step 2 Examine the LMA
- Visually inspect the LMA cuff for tears or other
abnormalities - Inspect the tube to ensure that it is free of
blockage or loose particles - Deflate the cuff to ensure that it will maintain
a vacuum - Inflate the cuff to ensure that it does not leak
78Step 3 Deflation Inflation
- Slowly deflate the cuff to form a smooth flat
wedge shape which will pass easily around the
back of the tongue and behind the epiglottis. - During inflation the maximum air in cuff should
not exceed - Size 1 4 ml
- Size 1.5 7 ml
- Size 2 10 ml
- Size 2.5 14 ml
- Size 3 20 ml
- Size 4 30 ml
- Size 5 40 ml
79Step 4 Lubrication
- Use a water soluble lubricant to lubricate the
LMA - Only lubricate the LMA just prior to insertion
- Lubricate the back of the mask thoroughly
- Important Notice
- Avoid excessive amounts of lubricant
- on the anterior surface of the cuff or
- in the bowl of the mask.
- Inhalation of the lubricant following placement
may result in coughing or obstruction.
80Step 5 Positioning of the Airway
- Extend the head and flex the neck
- Avoid LMA fold over
- Assistant pulls the lower jaw downwards.
- Visualize the posterior oral airway.
- Ensure that the LMA is not folding over in the
oral cavity as it is inserted.
81LMAInsertionTechnique
Step 1
Step 2
Step 3
Step 4
Step 5
82LMA Insertion Step 1
- Grasp the LMA by the tube, holding it like a pen
as near as possible to the mask end - Place the tip of the LMA against the inner
surface of the patients upper teeth
83LMA Insertion Step 2
- Under direct vision
- Press the mask tip upwards against the hard
palate to flatten it out. - Using the index finger, keep pressing upwards as
you advance the mask into the pharynx to ensure
the tip remains flattened and avoids the tongue.
84LMA Insertion Step 3
- Keep the neck flexed and head extended
- Press the mask into the posterior pharyngeal wall
using the index finger.
85LMA Insertion Step 4
- Continue pushing with your index finger.
- Guide the mask downward into position.
86LMA Insertion Step 5
- Grasp the tube firmly with the other hand
- Then withdraw your index finger from the pharynx.
- Press gently downward with your other hand to
ensure the mask is fully inserted.
87LMA Insertion Step 6
- Inflate the mask with the recommended volume of
air. - Do not over-inflate the LMA.
- Do not touch the LMA tube while it is being
inflated unless the position is obviously
unstable. - Normally the mask should be allowed to rise up
slightly out of the hypopharynx as it is inflated
to find its correct position.
88Verify Placement of the LMA
- Connect the LMA to a Bag-Valve Mask device or low
pressure ventilator - Ventilate the patient while confirming equal
breath sounds over both lungs in all fields and
the absence of ventilatory sounds over the
epigastrium
89Securing the LMA
- Insert a bite-block or roll of gauze to prevent
occlusion of the tube should the patient bite
down. - Now the LMA can be secured utilizing the same
techniques as those employed in the securing of
an endotracheal tube.
90Verify
- During ventilation observe end-tidal CO2 monitor
or pulseoximetry to confirm oxygenation
91Waveform Capnometry
- Prerequisite Requirement
- Becoming a standard of care
- Easy to Use
- Good measure of Pulmonary Perfusion
- Relates well to PaCO2
- Does have limitations
92Problems with LMA Insertion
- Failure to press the deflated mask up against the
hard palate or inadequate lubrication or
deflation can cause the mask tip to fold back on
itself.
93Problems with LMA Insertion
- Once the mask tip has started to fold over, this
may progress, pushing the epiglottis into its
down-folded position causing mechanical
obstruction
94Problems with LMA Insertion
- If the mask tip is deflated forward it can push
down the epiglottis causing obstruction - If the mask is inadequately deflated it may
either - push down the epiglottis
- penetrate the glottis
95Always expect the unexpected!
96RSI Procedure The Seven Ps
- 1. Preparation
- 2. Preoxygenate the patient
- 3. Premedicate the patient
- 4. Paralyze the patient
- 5. Pass the tube
- 6. Proof of placement
- 7. Post intubation care