Title: Introducing the Q-Series Outdoor Air Humidity Sensors!
1Introducing the Q-Series Outdoor Air Humidity
Sensors!
2Q-Series Humidity Sensors Whats So Exciting?
- Room, duct and now outside air humidity sensors
- Newly redesigned housing with a new look and feel
- A variety of versions for many different
applications - Signal options
- Accuracy options
- Many new features and accompanying benefits
- Very serviceable!
- Very affordable!!
3Q-Series RH Outdoor Air Sensors Applications
- Use in all standard applications for building
control - General HVAC Installations
- Energy Management Systems
- Critical Environments
- Enthalpy Control
4Q-Series RH Outdoor Air Sensors Features
- Offered as 2 or 2 certified versions
- Removable, replaceable sensing tips
- Available as RH sensing only or RH with
Temperature - Voltage and current output signals available
- Flexibility and ease of wiring connection
5Q-Series RH Outdoor Sensors Housing
- Small, sleek housing design for tight-fitting
spaces - Keyed housing cover
- Siemens name and part number are laser-etched
- On cover for clear viewing
- On base, to correctly mate to cover if they
become separated - UL Listed!
- Specs printed on outside cover
- Multiple conduit knockouts
- Clearly labeled wiring terminations
- Removable sun shield to protect sensor
6Q-Series RH Outdoor Air Sensors Design Details
- Jumper-selectable temperature ranges for better
control -
- Conduit clamp included
- Tighten down over 3/8 flex conduit to secure it
to the housing - Reversible clamp allows for strain relief if
jacketed wiring is used - Temperature-compensated element superior
accuracy! - Digital signal minimizes reading errors
7Q-Series RH Outdoor Air Sensors Accuracies and
Control Signals
- 2 Versions
- Accuracy over the range of 0-95 relative
humidity - Removable, replaceable sensing tips
- 2 Certified versions
- Matching bar code labels for housing base and tip
- 3 Point temperature and humidity calibration
- Replaceable tip ships with certification and
label - Active signals for Humidity or Temperature
- 0-10 Volts may be powered by AC or DC Voltage
- 4 to 20mA current
8Q-Series RH Outdoor Air Sensors Competitive
Summary
X Offered -- Not Offered
9Q-Series RH Outdoor Air Sensors Documentation
- Specification Sheet 149-992
- Installation Instructions 129-416
10Q-Series RH Outdoor Air Sensors -Selling
Arguments vs. Honeywell/Hycal HCT829
- Available as humidity only units
- Does not measure accurately above 90.
- Only available in a 4-20 mA version.
- Element does not recover well from 100
saturation. - Humidity element is not replaceable.
- Honeywell offers no versions with certification
11Q-Series RH Outdoor Air Sensors -Selling
Arguments vs. Johnson Controls (HE-67x3)
- Does not offer a removable, replaceable tip
- Only measures up to 90 relative humidity
- Cannot measure at 4 accuracy or better over the
80 rh - On RHT versions, sensor not temperature range
selectable - Element may not recover from 100 saturation
12Q-Series RH Outdoor Air Sensors -Selling
Arguments vs. Veris Industries HO Series
- Veris sensors not UL listed
- Product only measures accurately up to 90 rh
- Devices not range selectable on temp versions.
13Q-Series RH Outdoor Air Sensors -Selling
Arguments vs. ACI A/RHx-O types
- Sensing element not removable or replaceable
- Only accurate to 95 relative humidity
- SBTs device measures from 0-100 for the 2
model - ACI product not temperature range selectable
- ACI does not offer a UL listed product
14Selling Arguments vs. GE/ General Eastern
-Microline (MRH and MRHTx types)
- No removable tip must replace entire unit!
- Measures over a 20-95 rh range only
- MRHT products dont have temperature range
selectability - Poor accuracy
- Tests vs. GEI sensors under extreme conditions
showed new Siemens sensors perform much better
than Microline products!
15Q-Series RH Outdoor Air Sensors -Selling
Arguments vs. Kele
- Does not have their own product
- Resells ACI, Hycal/Honeywell, Vaisala, and GEI
products - Relies on service to gain market share
16Q-Series RH Outdoor Air Sensors -Selling
Arguments vs. BAPI the BA/H200, BA/H300
- Only measures to 95 rh
- Does not offer temperature range selectability
- Does not offer certified sensors
- Sensors are not UL listed
- Element will not recover from 100 saturation
17Q-Series RH Outdoor Air Sensors Selling
Arguments vs. Vaisala HMD60 or HMD70
- Does not offer temperature range selectable
- Does not offer UL listed devices
- Very expensive!!
- For a much lower price, Siemens Q-Series
humidity sensors - offer all the accuracy and reliability you need!
18Q-Series RH Outdoor Air Sensor Doubles as a
Critical Environment sensor!!
- Critical Environment and Lab applications
- Same 2 or 2 certified accuracy
- May be washed down
- Removable, replaceable tip
- Lumberg fitting for conduit connect
19Q-Series RH Outdoor Air Sensor Part Number
Listing
Sun Shield sold separately
20Q-Series RH Sensors Ordering
Example 4-20mA O/A, RH 2 QFA3101
21Order Your Q-Series Outdoor Air RH Sensors Today!