Thin Metal Films and Surface Plasmons - PowerPoint PPT Presentation

1 / 7
About This Presentation
Title:

Thin Metal Films and Surface Plasmons

Description:

Thin Metal Films and Surface Plasmons By: Joel Rovner and Will Bagienski Our Goal Was: Create thin films of metals Compare thickness measurements made by different ... – PowerPoint PPT presentation

Number of Views:86
Avg rating:3.0/5.0
Slides: 8
Provided by: physicsRu
Category:
Tags: film | films | metal | plasmons | surface | thin

less

Transcript and Presenter's Notes

Title: Thin Metal Films and Surface Plasmons


1
Thin Metal Filmsand Surface Plasmons
By Joel Rovner and Will Bagienski
2
Our Goal Was
  • Create thin films of metals
  • Compare thickness measurements made by different
    methods deposition monitor, resistance, and
    surface plasmon resonance.

3
Thickness Measurement
  • Deposition monitor
  • Uses a vibrating quartz crystal
  • Sensitive to added mass on crystal
  • Gives rate and total thickness
  • Resistance resistivity of silver
  • p 1.59 x 10-8 ohm meters
  • Area of film about 2.5 x 2.5 cm
  • Surface Plasmons
  • Laser table, measure reflected intensities,
  • Look for resonance

4
Surface Plasmons
  • Surface Plasmons are oscillations of the free
    electron gas at the surface of a metal.
  • In this lab we tried to detect them by shining a
    laser on the films.
  • If we could detect them we could have used our
    results to estimate the films thickness.
  • The dispersion relation for surface plasmons is
    ?ckxsqrt(1(1/1-(?p/?)2)).

Glass
Surface Plasmon
Metal
Air
5
Experimental Apparatus
  • The apparatus consisted of a digital light
    intensity meter, a red laser, an angle table, a
    power supply, and the thin film.
  • The angle of incidence of the laser was held
    constant and the detector arm was turned until
    the reflected light was detected.
  • Some of the problems that developed were that it
    was very difficult to make small changes to the
    angle of incidence and detect it without
    accidentally changing it.

Laser
6
Results
  • Indium 1 forgot to open shutter (oops)
  • Indium 2 meter thickness 500 angstroms, but
    didnt conduct, couldnt use other methods.
  • Silver 1 750 angstroms on meter, about 400
    angstroms by resistance, couldnt find SP
    resonance.
  • Silver 2 333 angstroms on meter, about 150 by
    resistance, still couldnt find SP resonance ?
  • Made nice mirrors though!!!

7
What went wrong?
  • Each time we evaporated, vacuum got a little
    worse, despite resealing.
  • Too much air in chamber, some reaction?
  • Uniformity of the film?
  • Tarnished?
  • Laser table and measurement procedure?
  • Resonance too small to see?
  • Something else?
  • The true thickness remains a mystery
Write a Comment
User Comments (0)
About PowerShow.com