Title: Thermal Bypass Checklist RoundTable
1- Thermal Bypass Checklist Round-Table
2WHAT IS THERMAL BYPASS?
30o F
50o F
70o F
70o F
3WHAT THERMAL BYPASS LOOKS LIKE
4GENERAL
- Builder not required to sign checklist if he/she
has not verified any items. - Maximum of four items allowed for builder refers
to numbered items, not bullets.
5THERMAL BYPASS CHECKLIST 1. INSULATION ALIGNMENT
Insulated sloped ceilings Air barrier required
except if closed cell spray foam
6THERMAL BYPASS CHECKLIST 1. INSULATION ALIGNMENT
- Doors to unconditioned spaces shall meet IECC
insulation requirements for exterior doors and
include full weatherstripping.
7THERMAL BYPASS CHECKLIST 1. INSULATION ALIGNMENT
Slab Edge Insulation (Climate Zones 4 and higher)
Plan for Flooring!!!
Interior
Exterior
8THERMAL BYPASS CHECKLIST 1. INSULATION ALIGNMENT
- Band Joists
- Highly encourage,
- but dont require complete air barrier detail
except - Garage/House Interface (Item 1)
- Cantilevered Floor (Item 6)
- Porch Roof (Item 12)
9THERMAL BYPASS CHECKLIST 2. SHOWER/TUB EXTERIOR
WALL
10THERMAL BYPASS CHECKLIST 3. INSULATED FLOOR
OVER GARAGE
Improper insulation! It must touch the surface
it is intended to insulate. Critical to check
for air gap!
11THERMAL BYPASS CHECKLIST 4. WALLS ADJOINING
UNCOND. SPACES
- Key Areas
- Attic Knee Walls
- Double Walls
- Skylight Shafts
- Porches (TBC 14)
12THERMAL BYPASS CHECKLIST 4. WALLS ADJOINING
UNCOND. SPACES
Double Walls
Heat
13THERMAL BYPASS CHECKLIST 4. WALLS ADJOINING
UNCOND. SPACES
Courtesy of Consol
14THERMAL BYPASS CHECKLIST 4. WALLS ADJOINING
UNCOND. SPACES
Courtesy of Consol
15THERMAL BYPASS CHECKLIST 4. WALLS ADJOINING
UNCOND. SPACES
Courtesy of Consol
16THERMAL BYPASS CHECKLIST 4. WALLS ADJOINING
UNCOND. SPACES
Skylight Shaft
Skylight
Attic
Air Barrier
Air Barrier
Insulation
17THERMAL BYPASS CHECKLIST 4. WALLS ADJOINING
UNCOND. SPACES
Tubular Skylight
14
Exposed area 30 sq.ft. Need insulation and air
barrier
1.2 diamater x 3.1412 x 8 30 sq. ft. exposed
surface area
18THERMAL BYPASS CHECKLIST 6. CANTILEVERED FLOOR
Tips Consider spray foam insulation installed to
desired thickness because it can serve as both
insulation and an air barrier. Critical to check
air gap at floor.
19THERMAL BYPASS CHECKLIST 8. FLUE SHAFT
TIP Specially colored fire-rated foam now
available for sealing difficult air gaps at flue
openings
Image courtesy of EnergyLogic
Image courtesy of EnergyLogic
20THERMAL BYPASS CHECKLIST 11. FIREPLACE SHAFT
WALL
21WRAP-UP
22ANSWER...
- One more thought
- It wasnt raining when Noah built the Ark.
- Howard Duff
23HOW TO GET MORE INFORMATION
- On the Web at
- http//www.energystar.gov/homes