Title: SMA Mixture Design Requirements
1SMA Mixture Design Requirements
Alexander W. (Sandy) Brown, P.Eng. Ontario Hot
Mix Producers Association - Technical
Director Asphalt Institute - Canadian Field
Engineer
2Overview
- Introduction
- What is SMA?
- Mixture Properties
- Mix Production
- Applications for SMA
- SMA Concerns
3Definitions
-
- Stone Mastic Asphalt (SMA) is hot mix asphalt
consisting of two parts a coarse aggregate
skeleton and an asphalt binder rich mortar. The
mixture has an aggregate skeleton with coarse
aggregate stone-on-stone contact.
4Definitions
-
- Stone Mastic Asphalt (SMA) Mortar means a
mixture of asphalt cement (and any additives),
filler (all material passing the 75 µm sieve from
the dry sieving of all aggregate components
including any commercial filler) and fibres
blended by volume.
5Stone Mastic Asphalt (SMA)
6Introduction
- What is Stone Mastic Asphalt (SMA)?
- SMA is a gap graded rut resistanthot mix asphalt
- Mix is composed of
- High Quality Aggregates
- Asphalt Rich Mortar
- Mineral Filler
- Cellulose Fibres
7Introduction
- Key Benefits of SMA
- Rut Resistant Mix
- Very High Skid Resistance
- Reduced Water Spray
- Noise Reduction
- Durable Mix
8Mixture Properties
- Governing Specifications
- AASHTO MP 8-051 Standard Specification for
Designing Stone Matrix Asphalt (SMA) - MTO OPSS 1151 (Nov. 2004)Material Specification
for Superpave and Stone Mastic Asphalt Mixtures
9Mixture Properties
- Ontario Mix Design Procedures
- CCIL Certified Type A or AMRL or equivalent
certified laboratory - 4 point mix design
- Superpave Gyratory Compactor (SGC)
- Ndesign of 100 gyrations
- Detailed mix design submission
- Job Mix Formula (JMF)
10Gradation Envelope
Sieve SMA 12.5 mm SP 12.5 mm FC1
19.0 mm 100 100
12.5 mm 90 99 90 100
9.5 mm 50 85
4.75 mm 28 40 45 60
2.36 mm 16 28 28 58
75 µm 8 11 2 10
11Mix Properties
Design Parameter Design Criteria
Air Voids 4.0
Voids in Mineral Aggregate, VMA 17 Minimum
VCAmix Less than VCA DRC
Tensile Strength Ratio 70 Minimum
Draindown 0.3 Maximum
12Air Voids
- Laboratory compaction by use of Superpave
Gyratory Compactor (SGC)
13Voids in Coarse Aggregate of Mix, VCA MIX
- Specification Less than VCA DRC
- VCA MIX The volume in between the coarse
aggregate particles. This volume includes filler,
fine aggregate, air voids, asphalt binder, and
fibre. - VCA DRC The volume in between the coarse
aggregate particles of the final job mix formula
in a dry rodded condition.
14Voids in Coarse Aggregate of Mix, VCA MIX
- VCA MIX lt VCA DRC to give the SMA Stone on Stone
Contact - This allows the coarse aggregate skeleton to
transfer the traffic loads
15Tensile Strength Ratio, TSR
- Specification 70 Minimum
- Checks the moisture susceptibility of the asphalt
mixture - Two acceptable test procedures
- Tensile Strength Ratio, AASHTO T283
- Retained Stability, LS-283
16Tensile Strength Ratio, TSR
17Draindown
- Specification 0.3 Maximum
- Tested at production temperature of asphalt
mixture for 1 hour - Mass of asphalt mortar that has drained from
total asphalt mass is determined and expressed as
percent of total mass of the original sample
18Draindown
19Asphalt Mortar
- Asphalt Cement, Mineral Filler, Fibres
- Provides coating of coarse aggregate skeleton to
- Protect from moisture and environment
- Bind the aggregate particles together
20Mix Production
- SMA can be produced in either batch or drum
plants - The production of SMA is better geared to large
tonnage projects - Consistent aggregate gradations are critical for
SMA production - Bailey method 2 change in PCS results in 1
change in voids
21Mix Production
- Production rates of SMA are based on plant
layout - 2 cold feed bins for CA, 1 for FA
- Mineral filler will need to be imported
- AC content is high schedule deliveries to keep
up with production - Method of fibre addition
- Bagged fibres by hand
- Air blown fibres
- Pelletized fibres
22Fibre Addition by Hand
23Applications for SMA
- MTO Directive PHY-C-016, The Use of Surface
Course Types on Provincial Highways, July 2002 - SMA is warranted whenESALS / design lane / year
exceeds 3 million - DFC or SP 12.5 FC2 is for 1 to 3 million
- Some Municipalities use SMA
24Concerns
- Durability of coarse aggregate
- LA abrasion lt 30 ?
- May be too high for some brittle aggregate
- VMA collapse
- Bridging over of voids
- AC content too high
- Low initial skid resistance
25Stone Mastic Asphalt (SMA)
26Stone Mastic Asphalt (SMA)
27Thank You