Title: ENCE 710 Design of Steel Structures
1ENCE 710 Design of Steel Structures
- IV. COMPOSITE STEEL-CONCRET CONSTRUCTION
- C. C. Fu, Ph.D., P.E.
- Civil and Environmental Engineering Department
- University of Maryland
2Introduction
- Following subjects are covered
- Composite Action
- Effective Width
- Nominal Moment Strength
- Shear Connectors, Strength and Fatigue
- Formed Steel Deck
- Reading
- Chapters 16 of Salmon Johnson
- AISC LRFD Specification Chapters B (Design
Requirements) and I (Design of Composite Members)
3Composite Action
4Effective Width
- AISC-I3
- Interior
- BE L/4
- BE b0 (for equal beam spacing)
- 2. Exterior
- BE L/8 (dist from beam center to edge of
slab - BE b0/2 (dist from beam center to edge of
slab)
5Nominal Moment Strength
Nominal Moment Strength of Fully Composite
Section (AISC 14th Edition Art.
I3.2a) 1. Mn based on plastic stress
distribution on the Composite Section
Fb 0.9 2. Mn based on
superposition of elastic stresses,
considering the effect of shoring Fb
0.9
6Plastic Stress Distribution
Case 1 (if a ts) S J Eq. (16.7.1 to 5) Case
2 (if a gt ts) S J Eq. (16.7.6 to 10)
7Shear Connectors
8Shear Variation
V Cmax 0.85fcbEts
V Tmax AsFy
N Cmax/Qn or Tmax/Qn Whichever is smaller
9Nominal Strength Qn
Qn 1. Headed Steel Stud (AISC Eq.
I8-1) 2. Channel Connectors (AISC Eq.
I8-2)
10Nominal Strength Qn
11Connector Design Fatigue Strength
(AASHTO LRFD Eq. 6.10.7.4.1b-1) Zr ? d 2
? 5.5 d 2/2 (AASHTO LRFD Eq.
6.10.7.4.2-1) where ? 34.5 4.28 log
N (AASHTO LRFD Eq. 6.10.7.4.2-2)
Example
12Composite Column Section (rolled steel shape
encased in concrete)
AISC I2.1. Encased Composite Columns AISC I2.2.
Filled Composite Columns (Ref Separate handout
with examples.)
13Composite Column Section (rolled steel shape
encased in concrete)
Using Effective Section Properties (I2-4, 5 6)
14Filled Composite Column Example
- AISC I2-2b
- Compact
- Noncompact
- Slender
15Filled Composite Column Example
- For compact sections
- Ac bfhfp(r-t)22bf(r-t)2hf(r-t)
- Ac (8.5 in.)(4.5 in.) p(0.375 in.)2 (8.5
in.)(0.375 in.) 2(4.5 in.)(0.375 in.) 48.4
in.2 -
-
- P0 (10.4 in.2)(46ksi) 0.85(48.4 in.2)(5 ksi)
684kips -
- EIeff (29,000 kis)(61.8 in.4) (0.90)(3,900
ksi)(111 in.4) - 2,180,000 kip-in.2
16Filled Composite Column Example
- Pe p2(2,180,000 kip-in.2)/(1.0(14 ft)(12
in./ft))2 762 kips - P0/Pe 684 kips/762 kips 0.898 2.25
-
- fcPn 0.75(470 kips) 353 kips gt 336 kips
o.k. -