Prsentation PowerPoint - PowerPoint PPT Presentation

About This Presentation
Title:

Prsentation PowerPoint

Description:

Slow control: light polarisation, temp. Fast control: Laser frequency for the cavity ... But the smallest is T the earlier the polarisation changing can be seen' ... – PowerPoint PPT presentation

Number of Views:29
Avg rating:3.0/5.0
Slides: 15
Provided by: sLY
Category:

less

Transcript and Presenter's Notes

Title: Prsentation PowerPoint


1
Introduction
  • Cavity Lpol
  • Present Status
  • Idea of optimisation

S. Baudrand Polarisation Optimisation
2
Cavity LPOL
3
Cavity fabry-perot principle
e beam
L
Linearpolar
Circularpolar.
When nLaser ? c/2L ? resonance
But Dn/nLaser 10-11 ? feedback laser/cavity
By tuning the laser frequency.

4
(No Transcript)
5
ZEUS
HERMES
6
New polarimeter using a fabry perot cavity
about 60 m
96 ns
Cavity
diffused g
Calorimeter
Laser
electron bunch
driver
electron beam
  • Infrared laser (l1064mm)
  • Fabry-Perot cavity (2m)
  • Compton scatering (e-g angle3.3 )
  • Slow control light polarisation, temp
  • Fast control Laser frequency for the cavity

7
Present status
8
Effect of radations at the calorimeter location
2003/2004
Hermes magnet if Off
Hermes magnet if On
9
Effect of radations at the calorimeter location
2003/2004
Hermes magnet if Off
Hermes magnet if On
We are waiting for a new calorimeter. Absorbers
in place should reduce the noise.
Cavity remain locked
10
Ideas of optimisation
  • Fabian and Christian did some very rough
    estimation on simple model 3 years ago

11
Polarisation measurment
  • 3 possibles experiments
  • Laser on Left or Right (2s each). Time to change
    polarity is only few ms.
  • Laser off (will not be implemented)

On line implemetation possible
12
Estimators
  • The Polarimeter will be running continuously and
    the two (left and right) histograms will be
    issued every 4 seconds.
  • dP of about 1 per mill (stat.) for summing all
    histograms for colliding bunches.
  • dP of about 3 per mill (stat.) summing all
    histograms for non colliding bunches.
  • dP of about 3 per mill (stat.) for individuals
    bunches but summing during one min.

?2 Estimation
Histograms are fitted on T in order to obtain a
precise value of P? and ?P? . Change can be
checked by redoing the same procedure again
Looking at the ?2 probability or change in P?.
13
Time in minits needed to get Q1
Direct comparison
T depends on the scenario chosen. The largest it
is, the more efficient is the optimisation on the
plateau. But the smallest is T the earlier the
polarisation changing can be seen
14
Conclusion
  • A Fabry-Perot cavity will be used for a new LPOL
  • 2003-2004 Radiation damage. 2005 shielding.
  • NOW, very stable running condition (with
    temperature control in the cavity house)
  • Ready to perform the alignment with the e- beam
  • A likelihood program is used to extract the
    polarisation from a first principle fit (few
    photon mode) to the photon energy spectra
  • The expected precision is ? 1/min/bunch (stat.)
  • 10/00 min (stat.) for all bunch to optimize the
    polarisation
  • Effect of synch. rads. are under studies but
    dont seems to have a dramatic effect on pol.
    measurement.
  • New calorimeter needed and should be installed
    soon