NEW MULTI-STAGE TOUCHSCREENS Features - PowerPoint PPT Presentation

1 / 51
About This Presentation
Title:

NEW MULTI-STAGE TOUCHSCREENS Features

Description:

Daylight Savings On/Off. Filter Days. Energy Usage Parameters. Celsius or Fahrenheit ... DAYLIGHT TIME. F. OFF. NEXT PAGE. LuxPro. Thermostats. Mt. Laurel, NJ ... – PowerPoint PPT presentation

Number of Views:167
Avg rating:3.0/5.0
Slides: 52
Provided by: Timo170
Category:

less

Transcript and Presenter's Notes

Title: NEW MULTI-STAGE TOUCHSCREENS Features


1
NEW MULTI-STAGE TOUCHSCREENSFeatures
Programming
2
NEW MULTI-STAGE TOUCHSCREENS
  • PSPU721T 2H/1C
  • PSPU732T 3H/2C
  • 7 Day Programmable OR
  • Non Programmable (Simple Mode)
  • Dual Fuel Capable w/optional Outdoor Wireless
    Remote Temp Transmitter.
  • Manual or Auto Humidity and De-Humidity Control
    (PSPU732T only)
  • Installer Message
  • Energy Watch Calculates Usage and Dollar
    Amount.
  • Screen Lockout
  • Much, Much, Much More..

VERY COMPETITIVE PRICING
3
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • On power up, to use the PSPU721 or 732 as a
    simple non programmable thermostat, touch the
    screen.
  • To switch from programmable mode to simple mode,
    remove the faceplate, press release the reset
    button on the bottom right. When Touch For
    Simple Thermostat comes up on the screen touch
    the screen and the t-stat will switch to Simple
    mode.

TOUCH FOR SIMPLE THERMOSTAT
4
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • Simple Mode puts the thermostat into non
    programmable mode where only temperature set
    point, cool/heat/auto mode, or fan operation can
    be changed.

46
72F
AUTO
FAN AUTO
72.0

-
5
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • For Programmable Mode, touch the screen. Now you
    can use all of the extensive programmable
    features to configure the thermostat the way you
    or the consumer wants it.

TOUCH FOR PROGRAMMABLE THERMOSTAT
6
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • Home screen shows temp set points, date, time,
    room temp, humidity, and outdoor temp if using
    optional wireless temp transmitter.
  • Touch the Screen anywhere to advance to Control
    Screen.

Run Program or Hold
Outdoor Temp
Room Humidity
Mode Setting
Fan Setting
Heat Set Point
Cool Set Point
Current time date
With Use of Wireless Remote Transmitter
7
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • The Control Screen is for the consumer to
  • make Temp changes,
  • set Humidity to Auto or Manual,
  • set Dehumidifcation
  • set Fan mode
  • put t-stat in Hold or Run Mode
  • access Installers Message.
  • Press Home Screen button to go back to Home
    Screen.
  • Press MENU to go to Main Programming Screen.

Run Program or Hold
Auto or Manual
Installers Message
Home Screen
Auto, Cool Heat, Emerg Heat or Off
RUN PROG
HUMIDITY MANUAL
Current room temp humidity
AUTO
46
70.0
Fan Auto, Fan Intermittent or Fan On.
FAN AUTO
-

DHUM
45
MENU
-

68.0 72.0
HEAT
COOL
Main Programming
Adjust temp and dehumidification settings
Current Mode Blinks
8
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • Main Menu Programming Screen allows owner to make
    adjustments, settings and programming choices.
  • Push Date / Time Settings

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
9
NEW TOUCHSCREENFEATURES/PROGRAMMING
DATE / TIME SETTINGS
  • Set date time by pressing each button
    individually.
  • Press MENU to go back to Main Programming Screen

24
12
CLOCK
SET TIME / DATE
12
33
PM
H M
MENU
07
20
08
H D Y
10
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • Push Program Settings to set daily temperature
    and fan settings.

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
11
NEW TOUCHSCREENFEATURES/PROGRAMMING
PROGRAM SETTINGS
  • Press day of week
  • 4 on/off periods per day.
  • Each day can be programmed differently.
  • Fan can be set differently for each period.
  • Each day can be copied to the next.

TU
MO
WE
TH
FR
SA
SU
1
FAN AUTO
EVENT
AM
30
07
START
MENU
HEAT COOL
-

68.0 72.0
12
NEW TOUCHSCREENFEATURES/PROGRAMMING
PROGRAM SETTINGS
  • After completing each days program, when you
    push the next day, the user is asked if they want
    to copy to the next day.
  • If YES, then you will continue to the following
    day and be asked the question again, etc.
  • If NO, then you program that day as you wish and
    proceed on to all the days of the week.
  • Press MENU when complete to go back to the Main
    Programming Screen.

COPY MONDAY SETTINGS
YES
NO
13
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • Push Energy Watch to see HVAC energy
    consumption and cost to date.

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
14
NEW TOUCHSCREENFEATURES/PROGRAMMING
ENERGY WATCH
  • Energy Watch shows energy consumption for up to
    255 days based on parameters set in Advanced
    Settings.
  • Owner can see energy usage and cost at anytime.
  • Hit the RESET button to zero out.

LAST 30 DAYS
  • HRS COMP.
  • 20 HRS FURN.
  • HRS FAN
  • HRS TOTAL
  • COST 20.30

RESET
MENU
15
NEW TOUCHSCREENFEATURES/PROGRAMMING
CLEAN SCREEN
  • By touching the Clean Screen button, you freeze
    the screen for 15 seconds so that you can
    wash/wipe it w/o changing any settings.

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
Consult owners manual for maintenance care
16
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • Push Set Screen to change screen settings.

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
17
NEW TOUCHSCREENFEATURES/PROGRAMMING
SET SCREEN
  • Backlight Can be set to Constant Light or Auto
    (touch the screen).
  • Reverse Change from B/W to W/B.
  • Night Reverse - Set for Auto screen reverse (chgs
    at 9PM and 6AM).

BACKLIGHT REVERSE NIGHT REVERSE CONTRAST
AUTO
ON
ON
MENU
07
18
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • Push Vacation Settings to set parameters for
    time temperature while away from the home.

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
19
NEW TOUCHSCREENFEATURES/PROGRAMMING
VACATION SETTINGS
  • Input leave (BEGIN) date, return (END) date and
    heat/cool temp settings.

VACATION SETTINGS
09
20
08
BEGIN
08
30
09
END
HEAT COOL
-

65.0 80.0
20
NEW TOUCHSCREENFEATURES/PROGRAMMING
  • Push Filter Monitor to see filter usage in days
    and to reset after changing filter.

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
21
NEW TOUCHSCREENFEATURES/PROGRAMMING
FILTER MONITOR
  • Filter Monitor Screen shows how many days current
    filter has been used (based on fan run time).
  • Reset button will set back to zero.

FILTER USED 15 DAYS
RESET
MENU
22
NEW TOUCHSCREENFEATURES/PROGRAMMING
HUMIDITY SETTINGS
  • Push this button to toggle between Humidify or
    Dehumidify mode.
  • More detailed settings for humidity control are
    available in Advanced Settings. (Installer
    settings)

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
23
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
  • Push hold the Advanced Settings button for 5
    seconds and the installer will be allowed to make
    additional and more detailed program settings.
  • The following screen will appear when entering
    Advanced Settings

DATE / TIME SETTINGS
ADVANCED SETTINGS
PROGRAM SETTINGS
VACATION SETTINGS
ENERGY WATCH
FILTER MONITOR
DEHUMIDIFY
CLEAN SCREEN
SET SCREEN
CAUTION Altering the system properties in the
ADVANCED SETTINGS may affect the performance of
the HVAC system and should be performed only by a
qualified installer.
24
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
  • Advanced Settings Screen allows installer to set
  • Daylight Savings On/Off
  • Filter Days
  • Energy Usage Parameters
  • Celsius or Fahrenheit
  • Security level
  • Installers message
  • Press FILTER to set Filter Monitor to Off/On
    number of days to monitor.

DAYLIGHT TIME
OFF
FILTER
ENERGY WATCH
F
NEXT PAGE
INSTALL MESSAGE
SECU-RITY
MENU
25
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
FILTER MONITOR
  • Turn Filter Monitor Off or ON.
  • An icon appears on the Home Screen when the
    Filter monitor is set to ON.

FILTER MONITOR
OFF
MENU
26
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
FILTER MONITOR
  • When you turn THE Filter Monitor ON, screen will
    then ask for the number of months (up to 6),
    based on fan run time, to notify consumer to
    change filter.

CHANGE FILTER
2
AFTER
MONTH
MENU
Return to Advanced Settings Screen
27
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
  • Push Energy Watch to set parameters for
    tracking HVAC energy usage and cost.

DAYLIGHT TIME
OFF
FILTER
ENERGY WATCH
F
NEXT PAGE
INSTALL MESSAGE
SECU-RITY
MENU
28
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
ENERGY WATCH
  • Set consumption KW parameters for compressor,
    furnace fan, and per hr KW cost.
  • This allows consumer to watch on going HVAC
    energy costs by pushing the Energy Watch button
    on the Main Menu Screen.

COMPRESSOR KW FURNACE KW FAN KW C / KWHr
5
5
1
MENU
13
Return to Advanced Settings Screen
29
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
  • Push Security to set level of screen lock
    preferred.

DAYLIGHT TIME
OFF
FILTER
ENERGY WATCH
F
NEXT PAGE
INSTALL MESSAGE
SECU-RITY
MENU
30
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
SECURITY
  • To turn Security on to FULL Lock or PARTIAL Lock,
    push OFF button.
  • You will be asked for a Pin . The default Pin
    is 1111.
  • To change your Pin push Change Pin and follow
    the prompts.

SECURITY
OFF
CHANGE PIN
MENU
FULL LOCK
31
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
SECURITY
  • Push the Lock button to toggle between FULL Lock
    and PARTIAL Lock
  • FULL Lock completely locks out the thermostat
    from unauthorized use w/o the Pin
  • PARTIAL Lock only allows the changing of the
    temperature setpoint.

SECURITY
OFF
CHANGE PIN
MENU
FULL LOCK
Return to Advanced Settings Screen
32
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
  • Push Install Message to input installer message
    and set frequency of display.

DAYLIGHT TIME
OFF
FILTER
ENERGY WATCH
F
NEXT PAGE
INSTALL MESSAGE
SECU-RITY
MENU
33
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
INSTALL MESSAGE
  • Message of up to 42 characters.
  • Message can be programmed to appear on a monthly
    basis.
  • Message can also be accessed by consumer by
    pushing the icon button on the Control Screen.

For Service Call ABC Htg at 777-555-4321
1 ABC
3 GHI
2 DEF
4 JKL
5 MNO
6 PQR
7 STU
8 VWX
9 YZ
0 /-
OK
MENU
34
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
  • Push Next Page to access Advanced settings for
    system type, cycles rates, staging temps, dual
    fuel, humidity and more

DAYLIGHT TIME
OFF
FILTER
ENERGY WATCH
F
NEXT PAGE
INSTALL MESSAGE
SECU-RITY
MENU
35
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
  • Heat Pump
  • 2 Stg HP
  • A/C
  • No Compressor
  • Electric Furnace
  • Gas Furnace
  • 2 Stg Gas Furn.
  • Oil Furnace
  • Select type of HVAC system.
  • Set Max Compressor Cycle Rate per Hr. (2 - 9)
  • Auto Change is minimum temp (dead band)
    difference between Heat/Cool set points. (1 5
    )
  • factory settings are recommended

HEAT PUMP
9
CYCLE RATE
NEXT PAGE
ELECTRIC FURNACE
3
AUTO CHNGE
ON
PREV PAGE
HP CUT OFF
40

MENU
CUT TEMP
PUSH NEXT FOR FURTHER SETTING
36
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
DUAL FUEL
  • Heat Pump Cut Off is for Dual Fuel applications.
    By turning the HP CUT OFF to ON, and setting the
    CUT TEMP (outside), the HP will shut down at that
    CUT TEMP and the gas furnace will take over.
  • Press NEXT PAGE for further settings

HEAT PUMP
9
CYCLE RATE
NEXT PAGE
ELECTRIC FURNACE
3
AUTO CHNGE
ON
PREV PAGE
HP CUT OFF
36

MENU
CUT TEMP
37
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
DUAL FUEL
  • Allows heat pump to operate with the furnace by
    changing to the ON position.
  • Press NEXT PAGE for further settings

HP WHEN
OFF
NEXT PAGE
FURNACE ON
PREV PAGE
MENU
38
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
MULTI-STAGE DIFFERENTIAL SETTINGS
  • 1st Stage Differential is the temp difference
    from set point that the heat or cool initiates.
  • 2nd Stage Differential is the temp difference
    from 1st stg set point 2nd stg start-up.
  • 3rd Stage
  • Set the reversing valve to energize in Heat or
    Cool depending on unit design

1ST STAGE DIF 2ND STAGE DIF
2
2
NEXT PAGE
2
PREVPAGE
3RD STAGE DIF OB ENERGIZED
MENU
COOL
Consult equipment manufacturers
operation/installation manuals before setting
these temperature settings.
PUSH NEXT FOR FURTHER SETTING
39
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
MULTI-STAGE DIFFERENTIAL SETTINGS
  • This time setting brings on 2nd stage (heat or
    cool) if system has not been able to reach the
    2nd stage temperature setpoint.
  • This avoids excessive compressor run time by
    bringing on the 2nd stage and full system
    capacity to meet setpoint.

IF STAGE 1 RUNS
NEXT PAGE
0
MINUTES
PREV PAGE
TURN ON STAGE 2
MENU
Consult equipment manufacturers
operation/installation manuals before setting
these temperature settings.
PUSH NEXT FOR FURTHER SETTING
40
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
HUMIDITY CONTROL
  • Humidity Fan When set to ON the fan will run
    when there is an independent call to humidify.
    When set to OFF, fan only runs during heating or
    cooling cycles.
  • De-Humidity Fan Same as above.

HUM FAN DH FAN
OFF
OFF
NEXT PAGE
OFF
PREVPAGE
DH REVERSE DHCONTCOMP
MENU
OFF
41
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
HUMIDITY CONTROL
  • DH REVERSE
  • ON - DH relay is normally closed when relative
    humidity is above DH set point.
  • OFF - DH relay is normally open when relative
    humidity is below DH set point.

HUM FAN DH FAN
OFF
OFF
NEXT PAGE
OFF
PREVPAGE
DH REVERSE DHCONTCOMP
MENU
OFF
42
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
HUMIDITY CONTROL
  • DH CONTROL COMPRESSOR
  • ON - Thermostat will turn off the air
    conditioning if either the dehumidify set point
    or the temperature set point is reached,
    whichever comes first, both DH relay and
    compressor will turn off.
  • OFF - DH relay is independent of compressor
    activity (DH becomes a spare relay and can be
    used for a variable speed fan or separate
    dehumidifier or air exchanger)

HUM FAN DH FAN
OFF
OFF
NEXT PAGE
OFF
PREVPAGE
DH REVERSE DHCONTCOMP
MENU
OFF
43
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
  • This screen allows you to calibrate temperature
    or relative humidity if found to be off.
  • Temperature accuracy is set at /-1 degree. It
    can be adjusted /- 9.5.
  • Humidity accuracy is /- 4. It can be adjusted
    /- 20.
  • Press NEXT PAGE for further settings

HUM
0

0
TEMP
0

PREV PAGE
MENU
44
NEW TOUCHSCREENFEATURES/PROGRAMMING
De-humidification options for increasing comfort
and efficiency
  • HRV/ERV units can be controlled by simply
    connecting the DH terminal on the thermostat to
    the terminal DH of the HRV/ERV. Most HRV/ERV
    units will control properly with the DH REVERSE
    feature turned off (contact normally open).
  • OPTION 1 In Advanced Settings choose DH
    ControlComp, set to ON then lower the temperature
    to a minimum safe set point, then set the desired
    de-humidity level. De- humidify will control the
    compressor (unless minimum temperature set point
    is reached) whichever comes first.

45
NEW TOUCHSCREENFEATURES/PROGRAMMING
De-humidification options for increasing comfort
and efficiency
  • OPTION 2 Connect terminal DH to Y1 and set
    thermostat to de-humidify mode. Then regardless
    of temperature the de-humidification setting will
    have priority. Caution This method will run the
    compressor until the de-humidification level is
    reached and may cause overcooling.

46
NEW TOUCHSCREENFEATURES/PROGRAMMING
De-humidification options for increasing comfort
and efficiency
  • OPTION 3 Connect the DH terminal to a variable
    speed fan control, (set DH REVERSE to control the
    fan so that low speed is activated to
    de-humidify). This method provides maximum
    comfort while maintaining the temperature in
    cooling mode.

47
NEW TOUCHSCREENWireless Remote Temp Transmitter
Mounting Bracket
  • Optional Wireless Remote Outdoor Temperature
    Transmitter for PSPU7 multi-stage touchscreens.
    Used for DUAL FUEL AUTOMATIC HUMIDITY CONTROL
    of central humidifier.

Indoor Receiver (plugs in at bottom of t-stat and
mounts under t-stat cover)
Optional Outdoor Wireless Remote Temp Transmitter
Kit WTR064
48
NEW TOUCHSCREENWireless Remote Indoor Receiver
PSPU Thermostat Screen
Plug antenna wire from Indoor Receiver into plug
located at bottom right of PSPU t-stat
Push Reset button on Indoor Receiver to initiate
communication between Outdoor transmitter and
Inside Receiver.
Plug Indoor Receiver into plug located at bottom
of PSPU t-stat
Indoor Receiver Unit installed
49
WIRING LEGEND
12
11
RC
DH
H
C
Y2
RH
OBW
W2
G
Y1
TERMINAL EQUIPMENT STANDARD COLOR Y1 First
Heat Pump Yellow and/or AC G Fan
Green W2 First Stage Furnace White OBW
Reverse Valve or Orange Second Stage
Furnace RH 24v Heat Transformer Red Y2 Second
Heat Pump Unknown and/or AC C Common
Blue H Humidity Control Unknown DH
Dehumidify Control Unknown Variable Fan
Control RC 24v Cool Transformer Unknown 11 and
12 Not Used
NOTE The above colors are standard in HVAC
industry. The wiring should be confirmed before
installation
50
TECHNICAL SUPPORT
  • For more information, tech sheets, submittals,
    please refer to the Instruction or Engineering
    Manuals, or access the LuxPro web site at
    www.luxproproducts.com.
  • Problems with installation or troubleshooting,
    please call our Technical Support team at (856)
    234-8803 Ext. 7 (530AM 2PM PST)

It is best if contractor is on jobsite when
calling Tech Support
51
LuxPro s Full Line of Residential Light Comml
Thermostats offer you the best VALUE. Thanks for
viewing our Touchscreen Presentation
Write a Comment
User Comments (0)
About PowerShow.com