Craft and Hawkins Department of Petroleum Engineering at LSU - PowerPoint PPT Presentation

1 / 9
About This Presentation
Title:

Craft and Hawkins Department of Petroleum Engineering at LSU

Description:

2 Parallel 250 bbl Mud Systems. w/ separate HT-400 Pumps. LSU ... Mud hopper. Inlet and outlet meters for gas and liquids. Circulation System Capabilities ... – PowerPoint PPT presentation

Number of Views:149
Avg rating:3.0/5.0
Slides: 10
Provided by: johnroge
Category:

less

Transcript and Presenter's Notes

Title: Craft and Hawkins Department of Petroleum Engineering at LSU


1
LSU Petroleum Engineering Research and
Technology Transfer Laboratory
The Well Facility
2
LSU WELL FACILITY
2 Parallel 250 bbl Mud Systems
w/ separate HT-400 Pumps
LSU Well 1
Five Additional Wells On-Site
3
Well and Flow System Capabilities
  • 2787 deep Well 1 simulating subsea well
    allowing gas injection and lost returns
  • 5884 deep Well 2 simulating surface well
    allowing gas injection and logs in annulus
  • 3 - 2000 deep gas storage wells
  • 1200 deep diverter demonstration well
  • 45, 0 - 90 degree, inclinable flow tube
  • 9600, 4.5 o.d. horizontal flow loop

4
LSU WELL 1
Control Room
Choke Manifold
LSU Well 1
Five Additional Wells On-Site
5
Circulation System Capabilities
  • 2 - HT400 cementing pumps
  • Two high capacity mud-gas separators
  • Two mud de-gassers
  • 3 - 200 bbl mud tanks special tanks
  • Choke manifold for up to 5 chokes
  • Multiple charge and transfer pumps
  • Shale shaker
  • Mud hopper
  • Inlet and outlet meters for gas and liquids

6
LSU WELL FACILITY
Two Halliburton HT-400 Pumps
7
Support Utilities
  • 480 vac, 3-phase, circuits up to 100 amps
  • 120 vac, 1-phase, circuits up to 30 amps
  • 100 psig air supply (30 hp)
  • City water
  • Well Water
  • Natural gas (600 psig continuous, up to 3500 psig
    intermittent)
  • Instrumentation for measuring pressure,
    temperature, and liquid and gas flow rates

8
High Pressure Natural Gas Compressor
9
Facilities to Support Training, Research, and
Testing
  • 2 - 20 person classrooms (1 with audio visual
    support, 1 adaptable as lunch room or demo room,
    includes 3 Restrooms)
  • Computer lab with 7 PCs
  • Labview data collection system
  • Mobile crane and fork lift
  • Indoor and outdoor shop areas
  • Guttered areas with drain to sump for catching
    spill and leaks
Write a Comment