Title: MEPCOM Operator Training
1MEPCOM Operator Training
2- BEFORE YOU START
- How to Adjust the Screen
- How to Use Touch Screen
3Screen Adjustment
Lift the silver/gray lever before adjusting the
viewing angle of the screen.
4Touch Screen Basics
Use the blunt end of a penciled or pen to touch
the screen
5Click On Topic
6HT Wizard Configuration
7USMEPCOM
8USMEPCOM
9Microphone Set Level
- Talk over Microphone
- Microphone is in the chassis
- Default is 50
USMEPCOM
10Instruction Set Level
- Automatic Instructions
- Default is 30
- See Audiometer Setup
USMEPCOM
11Speaker Set Level
- Chassis Mounted
- Default is 30
- External Speaker
- Jack for Noisy Environments
USMEPCOM
12Audiometer Setup
USMEPCOM
13Audiometer Setup
(Setup)
14Audiometer Setup
15Company Setup
Touch Info 2
USMEPCOM
Your MEPS Name Here
Booth No. XX / Position No. XX
16Company Setup
- Touch Clear
- First Letter Capitalized
- Touch Accept to Exit
Company Info 2
Your MEPS Name Here
17Company Setup
Touch Info 3
USMEPCOM
Your MEPS Name Here
Booth No. XX / Position No. XX
18Company Name
- Touch Clear
- First Letter Capitalized
- Touch Accept to Exit
Company Info 3
Booth No. XX / Position No. XX
19Audiometer Setup
20Examiner Setup
- Touch Add to Add Each Examiner
- Touch Sort to Move Most Used to Top
21Audiometer Setup
22Date Entry
- Touch Clear to Clear Previous Date
- Enter Current Date
- Date Stored Automatically
- Leap Year Calculated
- Touch Accept to Exit
23Audiometer Setup
24Time Entry
- Touch Clear to Clear Previous Time
- Enter Current Time in 24 Hour Format
- Before Noon, enter as hour
- After Noon Add 12
- Example 1PM is 13 Hours
- Time Retained During Power Off
- Touch Accept to Exit
25Audiometer Setup
26Screen Saver
- Touch Clear to Clear Previous Time
- Enter Time in Minutes
- Touch Accept to Exit
27Factory Defaults
28Restore Factory Default
- Touch Restore Factory Defaults
- Setup Password Required
29Delete Audiograms
Setup Password Required
30Passwords
USMEPCOM
1
3
2
31Passwords
- User Password Defaulted OFF
- Setup Password is Setup
- Dealer Password Overrides Setup and User
32HT Wizard Operator Training
33Hearing Testing
- Start By Touching the Test Button
- Touch Help for Assistance
USMEPCOM
34Hearing Testing
- Initial Screen
- May Have Previous Tests
- Start With New Test
USMEPCOM
35Hearing Testing
- HT Wizard Provides Reminders
- Touch Close
36Hearing Testing
The HT Wizard Always Asks for Operator
Verification Before Overwriting Valuable Test
Data.
37Hearing Testing
- Two Methods for applicant Data Entry
- New applicant (MEPs)
- Existing applicant
38New Applicant (MEPs)
- Enter SSN by Touching Keypad
- The - is Added Automatically if Selected in
Setup.
- Touch Bar at Top When Complete.
39Existing Applicant
- Enter SSN by Touching Keypad
- The applicants Name is Displayed on the Left if
a Match is Found
- Touch Bar at Top Left When Found.
40Touch No. The Type of Test will be defined
in a later step.
41Test Type
Touch Test Type
USMEPCOM
42Test Type
- Test Type is Auto Filled but Can be Changed
- For MEPs, before the test is started, Test Type
change to MEPS Accession Physical
- Test Type can be changed after the test is
concluded.
- Touch Accept to continue
43Select Examiner
Touch Examiner
USMEPCOM
44Select Examiner
Select Examiner from list Touch Exit to Continu
e
45Run Hearing Test
- The applicants Name and ID are Displayed
- Confirm Type Test and Examiner
- Touch Run to Play the Instructions and Start
the Hearing Test.
46Status Line
Run Hearing Test
Threshold Shift
- Status Line Displays Real Time Information
- Test Frequency Results are Displayed
- Threshold Shift Displayed (Should be 0 for MEPs
USMEPCOM
Test Results
47Demographics
- Enter While Test is Running
- Touch Subject Info
- Touch First Name to Start
- Only First Last Name
USMEPCOM
48First Name MI
- Enter First Name for New applicant
- Back Key for Entry Errors
- Clear Key to Clear
- Next Key to Next Field
49Last Name
- Enter Last Name for New applicant
- Back Key for Entry Errors
- Clear Key to Clear
- Accept Key to Exit
50Test Completion
- Test Prints on Completion
- For second copy touch Print Icon
USMEPCOM
Jack Foreman
Test Type MEPS Accession Physical
51Audiogram Report
Note the demographics information on the upper
portion of the audiogram
52Audiogram Report
- Test results are shown under the CT, Current Test
column
- BL, Baseline should be AA or the same as CT.
- Shift should be absent or zero (0)
53Audiogram Report
- Audiometer serial number
- Calibration date (Not Weekly Calibration
Verification Date)
- MEPs Classification Code
- Test Status
- Confirmation that the correct earphones were use
for the test
- Abbreviations for test
54HT Wizard Operator Maintenance
55Biological / Listening Check
- Touch the Tools Icon
- Touch Daily Biological
1
2
56Biological Check
57Biological Check
- The Oscar Plug is used during testing as a
substitute for the Oscar 7
- It is removed during the Daily Biological.
58Biological Check
- Oscar 7 must be connected
- Baseline is automatically selected
- Results printed on completion
59Listening Check
Select Listening Check
60Listening Check
Follow Instructions and Touch Passed
61Audiogram Review
- Review previous audiograms
- Touch Tools Review
USMEPCOM
1
2
3
62Review Data
- Select applicant by entering SSN
63Review Test Results
- All test results displayed
- Option to print selected
- Delete to remove
64Review Results
- Display results for selected applicant.
- Re-print audiogram by touching Print
- Display previous or following audiograms by
touching the Arrows
65Review Subject Info
View edit applicants demographic information
MEPS Accession Physical
66HT Wizard Operator Reports
67Daily Task - Reports
Reporting Function
USMEPCOM
1
3
2
68Reports
- The following reports are available
- Touch the check box for printing to an external
printer.
- Use Cancel Printing to cancel long reports.
69Daily Biological Report
Report of the weekly calibration verifications.
70HT Wizard Trouble Shooting
71Power On Red Screen
- Red lettering indicates abnormal configuration.
- Correct as instructed. This error indicates that
the green Oscar plug is not in place
72Power On Red Screen
This error indicates that the Left and Right
headphone plugs are reversed in the sound room or
the rear of the audiometer.
73Power On Red Screen
This error indicates that the handswitch is not
connected.
74Handswitch Substitution
The HT Wizard handswitch plug has three parts,
tip, ring and sleeve. The two part RA400
handswitch should not be used.
75Audiometer Support
Consult this screen for support contact
information
USMEPCOM
76The End Thank You for Your Attention Tremetr
ics 9675 W. 76th Street Eden Prairie, MN 55344