2- Question No 1
- Which of the following is the most reliable
method to estimate the effectiveness of standard
procedures to minimize the risk of
cross-contamination during spirometry testing in
a pulmonary function laboratory? - Count the number of disposable mouthpieces used
for 1 week. - Observe the handwashing behavior of each
technologist. - Ask patients tested about laboratory hygiene.
- Ask technologists if they wash their hands before
each test - Answer B Question No 2
- While performing duplicate blood gas analyses, a
pulmonary function technologist notes that the
second instrument gives consistently higher
values forPaCO2and PaO2. Which of the following
is the most probable cause of higher readings
from the second instrument? - The sample chamber temperature is greater than
37 C - An excessive delay occurred between running the
two samples - The PO2and PCO2electrodemembranes have protein
build-up - The sample chamber has a bacterial contaminate
- Answer A Question No 3
- Which of the following problems may be identified
by using an isothermal lung analog to perform
quality control on a body plethysmograph? - 1.Improperly calibrated mouth pressure transducer
- 2.Obstructed or perforated pneumotachometer
- 3.Increase in mechanical resistance
- 4.Malfunctioning box pressure transducer
3- Question No 4
- An isothermal lung analog has the following
specifications 5-L glass bottle - 2000 g of steel wool
- Density of steel wool 5 g/cm3
- Volume of connectors and bulb 100 mi-Repeated FRC
measurements in the plethysmograph result in a
volume of 5.5 L. Which of the following should a
pulmonary function technologist do? - Remove 500 g ofsteel wool from the lung analog
- Take the plethysmograph out of service
- Recalculate the BTPS correction
- Begin a biologic control program
- Answer D Question No 5
- A pulmonary function technologist is reviewing an
asthma action plan. The patient takes a low-dose
inhaled corticosteroid and a long-acting
beta2-agonist twice daily. The patient's
personal best peak flow is 600 L/min. Which of
the following instructions should be given to
the patient when the peak flow drops to 500
L/min? - Add montelukast (Singular).
- Continue the current regimen.
- Go to the emergency department.
- Double the steroid dose.
- Answer A Question No 6
- A treadmill belt stops for a fraction of a second
each time the patient takes a step. A pulmonary
function technologist should - Instruct the patient to use the hand rails.
- Tighten the belt.
4- Question No 7
- Prior to an exercise study, a pulmonary function
technologist finds that the patient's RER is - Which of the following best explains this
finding? - Carbohydrate metabolism
- Protein metabolism
- Hypoventilation
- Hyperventilation
- Answer D Question No 8
- A 6-year-old child has a history of repeated
episodes of wheezing and shortness of breath. A
pulmonary function technologist has difficulty
obtaining repeatable spirometry results. - Which of the following tests should be performed
next? - MVV
- DLco
- SGaw
- SpO2
- Answer A Question No 9
- A pulmonary function technologist is performing
an exercise (stress) test on a patient with
severe COPD. As the test progresses, the patient
shows signs of increasing dyspnea. - Measurements of inspiratory capacity decreased
from 2.0 L to 1.5 L. Which of the following most
likely occurred? - Dynamic hyperinflation
- Disconnected gas sampling line
5- Coronary blood flow
- Oxygen extraction.
- Answer C