Lecture 13 Bar Development - PowerPoint PPT Presentation

1 / 52
About This Presentation
Title:

Lecture 13 Bar Development

Description:

The minimum spacing of the bars is given as: ... General splitting of concrete along the bars,either in vertical planes as in ... – PowerPoint PPT presentation

Number of Views:272
Avg rating:3.0/5.0
Slides: 53
Provided by: ericsa3
Category:

less

Transcript and Presenter's Notes

Title: Lecture 13 Bar Development


1
Lecture 13- Bar Development
  • July 2, 2003
  • CVEN 444

2
Lecture Goals
  • Slab design reinforcement
  • Bar Development
  • Hook development

3
Flexural Reinforcement in Slabs
For a 1 ft strip of slab is designed like a beam
As (reqd) is in units of (in2/ft)
4
The table will allow to determine the amount of
steel per each foot of slab.
5
Flexural Reinforcement in Slabs
The minimum spacing of the bars is given as
Also, check crack control - important for
exterior exposure (large cover dimensions) - The
spacing S of reinforcement closest to the surface
in tension ACI Sec. 10.6.4
6
Flexural Reinforcement in Slabs
Maximum Minimum reinforcement requirements
  • Thin slabs shrink more rapidly than deeper
    beams.
  • Temperature shrinkage (TS) steel is provided
    perpendicular to restrain cracks parallel to
    span. (Flexural steel restrains cracks
    perpendicular to span)

7
Flexural Reinforcement in Slabs
Maximum Minimum reinforcement requirements
TS Reinforcement (perpendicular to span) ACI Sec
7.12.2
8
Flexural Reinforcement in Slabs
TS Reinforcement (perpendicular to span) ACI
Sec 7.12.2.2
t thickness of the slab
9
Flexural Reinforcement in Slabs
Flexural Reinforcement (parallel to span) ACI
Sec 10.5.4
Smax from reinforced spacing
10
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
A. Concept of Bond Stress and Rebar Anchorage
Internal Forces in a beam
Forces developed in the beam by loading.
11
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
A. Concept of Bond Stress and Rebar Anchorage
Forces in Rebar
Bond stresses provide mechanism of force transfer
between concrete and reinforcement.
12
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
Equilibrium Condition for Rebar
Note Bond stress is zero at cracks
13
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
Sources of Bond Transfer
(1) Adhesion between concrete reinforcement.
(2) Friction Note These properties are quickly
lost for tension.
14
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
(3)Mechanical Interlock.
The edge stress concentration causes cracking to
occur.
15
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
(3) Mechanical Interlock (cont).
Force interaction between the steel and concrete.
16
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
Splitting cracks result in loss of bond
transfer. Reinforcement can be used to restrain t
hese cracks.
17
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
Splitting Load is Affected by
18
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
Typical Splitting Failure Surfaces.
19
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
Typical Splitting Failure Surfaces.
20
Reinforcement Development Lengths, Bar Cutoffs,
and Continuity Requirements
21
Reinforcement Development Lengths
22
Reinforcement Development Lengths
23
Development Length for Bars in Tension
Development length, ld 12 ACI 12.2.1
fc 10000 psi for Ch. 12 provisions for
development length in ACI Codes.
Development length, ld (simplified expression
from ACI 12.2.2)
No. 6 and smaller No. 7 and larger bars and
deformed bars wires
Clear spacing of bars being developed or spliced
not less than db, clear cover not less than db,
and stirrups or ties throughout ld not less than
the code minimum or
Clear spacing of bars being developed or spliced
not less than 2db and clear cover not less than
db.
38 47.5
24
Development Length for Bars in Tension
Development length, ld 12 ACI 12.2.1
fc 10000 psi for Ch. 12 provisions for
development length in ACI Codes.
Development length, ld (simplified expression
from ACI 12.2.2)
No. 6 and smaller No. 7 and larger bars and
deformed bars wires
Other cases
57 71
fc 4 ksi fy 60 ksi , a,b,l 1.0
25
Development Length for Bars in Tension
Development length, ld ACI 12.2.3
26
Factors used in expressions for Development
Length (ACI 12.2.4)
a reinforcement location factor
where ab Horizontal reinforcement so placed that more than
12 in of fresh concrete is cast in the member
below the development length or splice
Other reinforcement
1.3 1.0
27
Factors used in expressions for Development
Length (ACI 12.2.4)
b coating factor (epoxy prevents adhesion
friction between bar and concrete.)
1.5 1.2 1.0
Epoxy-coated bars or wires with cover less than
3db or clear spacing less than 6db
All other epoxy-coated bars or wires
Uncoated reinforcement
where ab 28
Factors used in expressions for Development
Length (ACI 12.2.4)
g reinforcement size factor (Reflects more
favorable performance of smaller f
bars)
No.6 and smaller bars and deformed wire
No. 7 and larger bars
0.8 1.0
29
Factors used in expressions for Development
Length (ACI 12.2.4)
l lightweight aggregate concrete factor
(Reflects lower tensile strength of
lightweight concrete, resulting reduction in
splitting resistance.)
When lightweight aggregate concrete is used.
However, when fct is specified, shall be
permitted to be taken as but
not less than When normal weight concrete is used
1.3 1.0 1.0
30
Factors used in expressions for Development
Length (ACI 12.2.4)
c spacing or cover dimension, in.
Use the smaller of either (a) the distance from
the center of the bar or wire to the nearest
concrete surface. or (b) one-half the center-t
o-center spacing of the bar or wires being
developed.
31
Factors used in expressions for Development
Length (ACI 12.2.4)
Ktr transverse reinforcement index (Represents
the contribution of confining reinforcement
across potential splitting planes.)
The transverse reinforcement is the development
length in a column.
32
Factors used in expressions for Development
Length (ACI 12.2.4)
33
Factors used in expressions for Development
Length (ACI 12.2.4)
Note It is permitted to use Ktr 0 as a design
simplification even if transverse reinforcement
is present.
34
Excess Flexural Reinforcement Reduction (ACI
12.2.5)
Reduction (As reqd ) / (As provided )
- Except as required for seismic design (see ACI
21.2.1.4) - Good practice to ignore this provisio
n, since use of structure may change over time.
- final ld 12 in.
35
Development Length for Bars in Compression (ACI
12.3)
Compression development length,
ldc ldbc applicable reduction factors 8
in.
Basic Development Length for Compression, ldbc
36
Development Length for Bars in Compression (ACI
12.3)
Reduction Factors (ACI 12.3.3)
- Excessive Reinforcement Factor A(s reqd )
/ A(s provided)
37
Example - Development
For the cross section of a simply supported beam
reinforced with 4 8 bars that are confined with
3 stirrup spaced at 6 in. Determine the
development length of the bars if the beam is
made of normal weight concrete fc 3 ksi and fy
60 ksi
38
Example - Development
Check if conditions for spacing and concrete
cover are met
For 8 bars, db 1.0 in. Clear cover 2.5 in -
0.5 in. 2.0 in. db

Clear spacing between bars
39
Example - Development
Bars are confined with 3 stirrups. The
conditions are met. Determine the factorsa
1.0 (bottom bars), b 1.0 (no coating) and l
1.0 (normal weight concrete) and
54.8 psi 40
Example - Development
So ld 54.8(1.0 in.) 54.8 in. 55 i
n. Using the more general formula Ktr 0.0
41
Example - Development
c 1.17 in. controls
42
Example - Development
So ld 55 in.
43
Example - Development
If the same beam is made of light weight
aggregate concrete and the bars are epoxy coated
and As required for analysis is 2.79 in2
44
Example - Development
45
Example - Development
46
Critical Sections in Flexural Members
47
Critical Sections in Negative Moment Reinforcement
Three sections are critical for the negative
moment reinforcement Section 1 is at the face o
f the support, where the negative moment as well
as stress are at maximum value. Two development
lengths, x1 and x2 must be checked.
48
Critical Sections in Negative Moment Reinforcement
Section 2 is the section where part of the
negative reinforcement bar can be terminated. To
develop full tensile force, the bars should
extend a distance x2 before they can be
terminated Once part of the bars are terminated
the remaining bars develop maximum stress.
49
Critical Sections in Negative Moment Reinforcement
Section 3 is a point of inflection The bars shall
extend a distance x3 beyond section 3 x3 must
be equal to or greater than the effective depth
d, 12db or 1/16 the span, which ever is greater.
At least 1/3 of the total reinforcement provided
for negative moment at support shall extend a
distance x3 beyond the point of inflection.
50
Critical Sections in Positive Moment Reinforcement
Section 4 is that of maximum positive moment and
maximum stresses. Two development lengths x1 and
x2 have to be checked. The length x1 is the
development length ld specified by the ACI Code
Section 12.11. The length x2 is equal to or
greater than the effective depth d, 12db .
51
Critical Sections in Positive Moment Reinforcement
52
Critical Sections in Positive Moment Reinforcement
Section 6 is at the points of inflection limits
are according to section 12.11.3 of the ACI Code.
Write a Comment
User Comments (0)
About PowerShow.com