Title: Columns and Supplies
1Tetracyclines in Chicken using Solid Phase
Extraction (SPE) and HPLC/UV
- Chen-Hao (Andy) Zhai
- Agilent Technologies
- October 2008
2Abstract
- A method for the determination of residual
Tetracyclines in chicken has been established - Tetracyclines were extracted from chicken with
EDTA-McIlvaine buffer - Clean up was performed using Agilent SampliQ OPT
solid phase extraction cartridges - Eluate was analyzed by HPLC with DAD
- Limits of detection (LOD) were between 2.5 and 5
ug/kg - Calibration curves were linear over the range of
25 to 500 ug/kg - Recoveries based on solution standards were
between 52.0 and 99.0 with RSD (n6) values
between 1.0 and 6.5
3Introduction
- Tetracyclines is the name used for a class of
antimicrobials which all contain a
hydronaphthacene backbone. - Effective against a wide range of gram negative
and gram positive micro-organisms. - Most governments now regulate the amount of
residual tetracyclines found in food,
particularly animal tissues
4Materials
- Standards All reagents and solvents were HPLC or
analytical grade - Tetracycline standards were purchased from
Sigma-Aldrich or NICPBP - Stock solution (0.1mg/mL) prepared in methanol
and kept in the freezer (-20C) - Working solutions prepared using the stock
solution diluted with a mixture of methanol /
10mM trifluoroacetic acid solution (1/19) - Working solutions prepared daily
- SPE cartridges Agilent SampliQ OPT 3mL, 60mg
(Part 5982-3036) - Solutions McIlvaine buffer, mix 1000mL 0.1M
citric acid with 625mL 0.2M disodium hydrogen
phosphate (pH adjusted to 4.0 0.05 with NaOH or
HCL as needed) - Na2EDTA-McIlvaine buffer (0.1M), mix 60.5g
Na2EDTA.2H2O into 1625 mL McIlvaine buffer. - 10mM TFA solution 0.765 mL trifluoroacetic acid
dissolved in water to a final volume of 1000mL. - Methanol-TFA solution 5 methanol in 10mM TFA
solution
5Materials and Methods HPLC
- Chromatography System Agilent 1200 HPLC ,
quarternary pump, autosampler, thermostatic
column compartment, diode array detector - HPLC conditions
- Column Agilent Zorbax SB-C8 2504.6mm 5µm (Part
880975-906). - Flow rate 1.5ml/min
- Column Temperature 30oC
- Injection volume 100µl
- Detector wavelength 350nm
- Mobile phase 10 mmol/L TFA solution, methanol,
acetonitrile, gradient elution
6Methods Sample Preparation
Table 1 Physical-Chemical Properties of
Selected Tetracyclines
- The physical-chemical properties of the seven
tetracyclines compounds are shown in Table 1 and
the chemical structures are shown in Fig. 1 - The method used for the preparation of the
chicken tissue is shown schematically in Fig. 2 - 200g chicken was homogenized and placed in a
clean, sealed container and stored at -18oC - 5g homogeneous sample (accurate to 0.01 g) was
placed into a 50 mL polypropylene centrifugal
tube with 20mL 0.1 mol/L Na2EDTA-Mcllvaine buffer
solution and vortexed for 1 minute followed by a
10 minute ultrasonic extraction in an ice bath. - Sample was then centrifuged at a speed of 3000
r/min for 5 minutes (below 15oC). - The supernatant was removed and saved in a clean
tube. - The extraction was repeated twice with 20mL and
10mL successively and the combined supernatants
were brought to 50 mL with buffer, mixed well,
and centrifuged at a rotate speed of 4000 r/min
for 10 min (below 15oC), then filtered.
7Chemical Structures of Tetracyclines
8SampliQ OPT Sample Preparation Chicken Muscle
Accurately weigh 5g raw, homogenized chicken meat,
Homogenize 1 min. in 20mL 0.1M Na2EDTA-McIlvaine
buffer
Ultrasonic extraction in ice bath for 10 min.
Centrifuge 3000rpm 5min transfer supernatant to
centrifuge tube B
repeat 2x, 20mL and 10mL successively
Bring total supernatant to 50mL final vol.
Centrifuge at 4000 rpm for 10 min.
Filter, take 10mL for SPE
9Methods SPE Purification
- The procedure used for the SPE extraction is
shown in Figure 3 - Agilent SampliQ OPT cartridges were
preconditioned with 5mL methanol then 5mL 10mM
TFA solution. - 10 mL extract (equivalent to 1 g sample) was
passed through the SampliQ OPT cartridge at a
speed of 1mL/min. - After it effused completely, the cartridge was
washed with 3 mL water (pH adjusted to 4.5 with
TFA) and the entire effluent was discarded. - The cartridge was dried under a negative pressure
(below 2.0 kPa) for 3 minutes - Sample is eluted with 10ml of 10mmol oxalic acid
in methanol (Oxalic acid acts as a chelating
agent and maintains the pH where tetracyclines
are most stable) - Eluent was collected and dried under nitrogen
below 40oC. - Residue was dissolved and made to a constant
volume of 0.5mL using the methanol-TFA solution,
filtered through a 0.45 µm filter membrane, and
analyzed
10SampliQ OPT Process for 3mL Cartridge
Condition 5mL methanol
Equilibrate 5mL 10mM TFA (pH 2.16)
Load 10mL extract (equivalent to 1g meat)
Recommended flow through cartridge not faster
than 1mL per minute
Wash 3mL water (adjust pH to 4.5 w/ TFA)
Dry 3 minutes under vacuum
Elute with 8mL 10mM Oxalic acid in MeOH
Dry, reconstitute in 5 MeOH 10mM TFA
Filter
11 Results - Linearity and Limits of Detection
- Stock solutions were diluted to different
concentrations and analyzed by HPLC - Linear regressions were calculated for the
tetracyclines based on the areas and the solution
concentrations - Limit of detection (LOD) was the injection
concentration which signal to noise ratio was
between 2 and 3 - Linear range was between 25-500µg/kg. The
linearity and LOD are shown in Table 2
Table 2. Linearity and LODs of Tetracyclines
12Recovery and Reproducibility
- The precision of the method was determined as
recoveries of spiked tetracycline standards in
chicken at 50µg/kg, 100µg/kg and 200µg/kg levels - The analysis was performed in replicates of 6 at
each level - The chromatograms of the blank and spiked
standard are shown in Figure 4 and Figure 5. - The recovery and reproducibility data are shown
in Table 3.
13Figure 4. Chromatogram of chicken blank
Figure 5. Chromatogram of a chicken sample spiked
with 1-minocycline, 2-oxytetracycline,
3-tetracycline, 4-demeclocycline,
5-chlortetracycline, 6-demeclocycline,
7-doxycycline
14Recoveries and RSDs of Tetracyclines in Chicken
15Conclusion
- Agilents SampliQ OPT, a polymeric sorbent with
combined hydrophilic and lipophilic
characteristics that allows retention of both
polar and non-polar compounds, provides a
simplified and effective single cartridge method
for the purification and enrichment of multiple
tetracycline compounds in chicken - Recovery and reproducibility (routinely below 5)
based on solution standards are acceptable for
tetracycline residue determination in chicken
under the Chinese regulation - Impurities from chicken were minimal and did not
interference with any of the tetracyclines
analyzed - LODs of the 7 tetracyclines were much lower than
the MRL (100µg/kg)
16Reference
GB/T 21317-2007, Determination of tetracyclines
residues in food of animal originLC-MS/MS method
and HPLC method