ZOLL Medical CorporationSales Training
M Series 12 Lead
2
12-lead ECG
3
Agenda
  • Introduction
  • What is a 12-lead?
  • Features and Benefits
  • Demonstration
  • In-Service
  • Hands-on

4
FACTS
  • AMI ( Acute Myocardial Infarction ) is THE
    leading cause of death in the US
  • 1.1 MILLION people have an MI annually
  • 439,000 women
  • 668,000 Men
  • Approx 500,000 will die
  • Costs for CAD ( Coronary Artery Disease ) in the
    US in 2001 were 298 billion
  • NRMI ( National Registry Myocardial Infarction)
    Database

5
Indications for the 12-lead ECG
  • Chest Pain
  • Stroke
  • Dysrhythmias
  • Post-Resuscitation
  • Following Emergency Cardioversion
  • Suspected Electrolyte Disturbances
  • For Asystole confirmation
  • PEA ( Pulseless Electrical Activity) to identify
    cause

6
12-Lead ECG KNOWLEDGE
  • Ischemia
  • Lack of oxygenation
  • ST depression or T inversion
  • Injury
  • Prolonged ischemia
  • ST elevation
  • Infarct
  • Death of tissue
  • May or may show in Q wave

7
ST Segments
8
12-lead ECG
9
12-lead Electrode Placement
  • V1- Right parasternally,4th Intercostal space
  • V2 - Left parasternally, 4th intercostal space
  • V3 - Directly between V2 and V4
  • V4 - 5th intercostal space,left mid clavicular
    line
  • V5 Directly between V4 and V6
  • V6 Left midaxillary line , same plane as V4

10
12-Lead ECG KNOWLEDGE
  • Inferior Wall
  • Leads II, III, aVF
  • Left Leg

11
12-Lead ECG KNOWLEDGE
  • Lateral Wall
  • Leads I and aVL
  • Left Arm

12
12-Lead ECG KNOWLEDGE
  • Septal Wall
  • Leads V1, V2
  • Along sternal borders

13
12-Lead ECG KNOWLEDGE
  • Septal Wall
  • V3, V4
  • Left anterior chest

14
12-Lead ECG KNOWLEDGE
  • Lateral Wall
  • Leads V5 and V6
  • Left lateral chest

15
12-Lead ECG KNOWLEDGE
  • The three ECG subsets
  • Non diagnostic no ST or T wave abnormalities
  • Suspicious for ischemia ST depression or T wave
    inversion
  • Suspicious for injury ST elevation

16
12-Lead ECG KNOWLEDGE
  • Whats the Value of a12-Lead?
  • Provides baseline ECG before treatment
  • Early and rapid identification of AMI
  • Triage to correct facility
  • Cath Lab or Thrombolytics
  • Quicker diagnosis
  • Reduced time to triage / treatment in hospital
  • Improved patient care

17
M Series with 12-lead ECG option
  • Features and Benefits

18
12-Lead ECG KNOWLEDGE
  • Description
  • Simultaneous 12-lead ECG acquisition, storage,
    display, transmission and analysis
  • Uses GE Medical Systems 12SL analysis program
  • Interface with MUSE for direct transmission of
    12-lead ECG records from defibrillator to
    hospital MUSE system.

19
12-Lead ECG UNDERSTANDING
  • Key Differentiators
  • AHA Class I recommendation
  • GE 12SL Gold Standard for analysis
  • Direct transmission to MUSE
  • Bluetooth Wireless Options
  • Module to Interlink to RescueNet Code Review
  • Fax and email
  • Bluetooth Activation Pod Kit
  • Fax or MUSE

20
The GE 12SL PROGRAM
  • Background
  • Validated on clinically correlated Gold
    Standard databases
  • Annually evaluated by a group of over 50 top
    consulting Cardiologists and physicians from
    around the world ( ECG Analysis seminar)
  • Detailed Physicians Guide explains the ECG
    Analysis morphology ( obtained from GE)

21
12SL PROGRAM
  • KEY Points
  • Worldwide name recognition (Analysis by 12SL)
  • Introduced in 1980 and consistently enhanced
  • Most independently validated algorithm in the
    scientific literature
  • Adult Pediatric programs available
  • Published statement of Validation Accuracy
  • Established value and is now the Standard of Care

22
Sensitivity
  • Refers to recognition
  • If the test always recognizes the disorder,
    sensitivity would be 100
  • False negatives are failures of sensitivity
  • A false negative occurs when the condition
    exists but the test fails to find it

23
Specificity
  • Refers to the number of diagnoses confirmed
  • If the diagnosis were corroborated every time the
    test identifies it, it would be 100 specific
  • False positives are failures in specificity
  • A false positive occurs when the test indicates
    the disease is present, when in fact it is not

24
GE 12SL PROGRAM
  • Infarction
  • Sensitivity 65 ( refers to recognition)
  • Specificity 98 ( refers to diagnostic accuracy)
  • Overall 74 sensitivity for Chest Pain Patients
  • clearly adequate for first line screening of
    patients with chest pain by paramedics or in the
    ER.
  • specificity is superior to that of the
    trained electrocardiographer

25
12-Lead ECG KNOWLEDGE
  • 12-lead Summary Reports
  • 4x3 Prints 10 seconds of 12-lead ECG in four
    staggered 2.5 second segments (default)
  • 4x3 Median Prints single median beat for each
    of the 12 leads as computed by 12SL algorithm
  • 2x6 Prints all 12-lead ECG data recorded during
    first 5 second interval. Inhibits printing of
    the 12SL analysis and lead II rhythm strip
  • Measurement Matrix Prints measurements for each
    segment of each lead. This option must be
    changed in the configuration menu.

26
M-Series ECG Filters
  • Normal Monitoring Bandwidth is 0.5 to
    30/40 Hz ( Frequency Response)
  • Diagnostic 12-lead monitoring is done at 0.05 to
    150 Hz ( AAMI standard ( American Association of
    Medical Instrumentation)
  • Diagnostic 12-lead can also be done at 0.05 to
    40Hz ( to reduce noise)

27
Features and Benefits
  • Integrated in the M Series
  • Easy to Use
  • Recorder Button automatically provides 4x3
    printout
  • 12-lead Acquisition Button Provides 4x3,
    Interpretation and Measurements
  • Faster 12-lead print-out v LP12
  • Prints the first 3 lead groups after 2.5 seconds
  • LP12 waits 10 seconds and then prints 12-lead
    report

28
Features and Benefits
  • One-Step Patient Cable
  • Ease of Configuration
  • 12SL Analysis Implementation
  • Fast Acquisition
  • Compressed ECG pre transmission

29
Features and Benefits
  • Fax/Modem Card 12-lead Transfer today
  • Wireless coming in Oct 2003
  • 12-lead ECG compression
  • LP12 Physio sends raw ECG data
  • M Series compresses before we send
  • MAY help transmission speeds!!
  • Preconfigured telephone numbers
  • Saves time / easy /Auto redial
  • Manual dial option ( Buried in LP12 configuration)

30
Why ZOLLs 12-lead?
  • Key Points
  • GE Medical Systems 12SL Analysis Program
  • Rapid 12-lead Acquisition
  • ECG compression for transmission
  • Transmission capabilities of M Series
  • 12SL Best in Class v other ECG Programs
  • Cost-effective pricing
  • Connectivity options ie MUSE

31
12-lead ECG APPLICATION
  • 12-lead Demo

32
M Series 12-lead
  • Being prepared
  • Review Operators Guide
  • Review 12-lead Monitoring Insert
  • Understand electrode placement
  • V1 4th intercostal space at right sternal margin
  • V2 4th intercostal space at left sternal margin
  • V4 5th intercostal space on left midclavicular
    line
  • V3 Between V2 and V4
  • V5 Left anterior axillary line at horizontal
    level of V4
  • V6 Left midaxillary line at horizontal level of
    V4

33
Demo Tips
  • Configure the device to automatically transmit
    after a 12-lead
  • Have a 12-lead simulator
  • Pre-connect all leads to the simulator
  • Have the M Series already in 12-lead monitor mode
  • Configure to come up in Lead II
  • Do not enter in the age, gender or ID
  • Explain how M Series 12-lead begin to print out
    after the first 2.5 seconds on the Leads I , II ,
    III
  • LP12 waits 10 seconds before print out
  • Explain how ZOLL compresses the data
  • V-Pak electrode samples

34
M Series 12-lead
  • Have the proper equipment!
  • 12-lead cables!!!!!!!!!!!!!!!
  • 12-lead simulator
  • Fresh batteries
  • Pre-attached leads
  • Configure M Series for desired operation
  • Carry a spare modem card and cables
  • TEST THE TRANSMISSION IN ADVANCE

35
12-Lead ECG KNOWLEDGE
  • Basic Operation - 12-Lead Acquisition
  • Attach electrodes
  • Turn selector switch to MONITOR
  • Press 12 LEAD soft key to enter 12-lead menu
  • Acquire, Settings, PT Info, Alarms is displayed
  • Press ACQUIRE to begin 12-lead acquisition (takes
    10 seconds)
  • Wait for ACQUISITION COMPLETE message before
    patient movement allowed
  • Transmission screen will automatically be
    displayed after acquisition if configured
  • To print only Press and hold PRINT for 3 seconds

36
  • 12 Lead Miscellaneous

37
12-lead Accessories
  • Modem Extension Cable Revision B (Dec 02)
  • Connects to Ositech King of Hearts or Viking
    Cellular Ready modems only
  • Does not fit the older Viking Modem cards
  • Part 8000-0086
  • Xtreme Pak
  • Comes with modem cable built in to plate
  • See Bulletin 52802 for all Part
  • Sales Bulletin 55302 /52602 for details

38
M Series 12 Lead Opportunities
  • Adding 12 lead increases ASP and gets you to
    quota faster
  • 7,395.00 is like selling two defibrillators
    instead of one

39
Qualifying Questions
  • Is 12-lead currently in your scope of practice?
  • What is your current protocol for AMI assessment
    in your department?
  • What 12-lead devices do you currently use?
  • Are you transmitting 12-leads? If so, where to?
  • Once in the ER, how long does it take before a
    12- lead ECG is taken?
  • Whats your average on scene time?
  • Do you have a 24 / 7 Cath lab in your area?

40
Troubleshooting 12-lead
  • Do they prep the skin before applying the ECG
    electrodes to the patient?
  • Were the electrodes pre-attached potentially
    drying out the electrodes?
  • Is there proper lead placement?
  • Check for placement on boney prominences or for
    correct lead placement.
  • Do they place the limb leads on the chest or
    limbs?
  • Check to make sure the ER does the same
    placement.
  • If they transmit, do they have drop out areas?
  • If they get a fax busy signal, does the ER have a
    dedicated fax machine?
  • Have they programmed their M Series with the
    appropriate fax numbers and cell phone?

41
12-lead ECG UNDERSTANDING