Title: E 1
1MEIDEX - Crew TutorialInstrumentation Adam D.
Devir, MEIDEX Payload Manager
2Payload Instrumentation
- Sekai RSC-310
- General View
- Components and Interfaces
- Operating Procedures
- Sekai ADVCR-101
- General View
- Basic Interfaces
- Operating Procedures
- Vibration Tests
- Instrumentation and Avionics on AMP
- Introduction
- Payload Instruments
- Xybion IMC
- General View
- Components
- Basic Interfaces
- Baffle, Optical Bench and Truss Mechanism
- Optics
- Principle of Operation
- The MCP
- Command Tree
- Operating Procedures
3Introduction
- The Mediterranean Israeli Dust Experiment
(MEIDEX) will fly on a shared STS mission as a
complex secondary payload. Its primary mission
objective is to monitor and provide by a Xybion
Intensified Multispectral Camera (IMC-201)
radiometric image data of atmospheric desert
aerosol plumes. A secondary wide field of view
(FOV) camera will be used to monitor the larger
area surrounding the narrow FOV of the
radiometric camera. Imaging data will be recorded
on an on-board digital VCR for analyses. Using a
portable laptop computer, the astronaut in the
shuttle will control the camera operation, VCR
record status, and experiment pointing during the
course of the mission.
4Payload Instruments
- Payload instruments
- Xybion Intensified Multispectral Camera (IMC)
serves as the main - radiometric scientific equipment
- SEKAI RSC-310 Wide Field of View (WFOV) camera
serves at a view finder color camera - SEKAI ADVCR-101 digital VCR (3 units)
- All payload instrumentation is located in HH
canister (with 5 extension ring) - The Xybion IMC-201 and the SEKAI RSC-310 are on
the movable Truss. - The 3 SEKAI ADVCR-101 are located under the
Avionics Mounting Plate (AMP) which is 6 above
the Lower End Plate (LEP) of the canister. - On the AMP are located the following avionics are
- The Electrical Power Supply (EPS) with the Sekai
CCD P/S. - Control and Data Handling unit (CDH).
- The Junction Box.
5Xybion IMC - General View
6Xybion IMC - Components
7Xybion IMC - Basic Interfaces
8Xybion IMC-210 - Baffle Design
9Lens Support Bracket and Optical Bench
10Optical Bench in The Truss Mechanism- Drive Train
Side
11Optical Bench in The Truss Mechanism- Brake Side
12Truss Mechanism - Top View
13Optical Bench and Truss Mechanism in the
Canister Assembly
14The HH Canister on the Bridge
MEIDEX
15The HH Canister on the Bridge
MEIDEX
16Xybion IMC-201 - Optics
The Hamamatsu A4869 lens has a focal length of is
50.4mm (F/3.5). The lens is composed of 5
elements (Fluorite and Fused Silica) in 5 groups.
Total transmittance of the lens is gt70. The
total FOV of the lens is 13.93o (H) x 10.66o (V).
17Xybion IMC-201 - Principle of Operation
18Xybion IMC-201 - Principle of Operation
- Photons are passing through the filter and
hitting the photocathode (PC) - The PC is converting the photons to
photo-electrons. - The quantum efficiency of the PC varies from20
in the UV 200nm) to 2 in the NIR (850nm) - see
next page. - The electrons are accelerated from the PC by a
gated voltage difference - VPC towards the
negative plate of the Multi-Channel Plate (MCP)
that is at voltage of about -800V. - The gating of this voltage difference turns the
PC negative in relation to the MCP thus allowing
the electrons to reach the MCP during the gate
interval - The gating pulse is rectangular with varying
width that varies from 50nsec to 4msec. - The gating pulse is synchronized with the
position of the filter wheel in such way that it
coincides with the exact overlapping of the
filter diameter (25mm) with that of the PC.
19Xybion IMC-201 - Quantum Efficiency
20Xybion IMC-201 - Principle of Operation
- The MCP amplifies the number of the electrons as
a function of the voltage difference between its
two sides - see next slide - The relation between the voltage difference and
the amplification of the number of electrons is
shown in the next slide as a function of the
voltage - V applied to the MCP and the parameter
a that is the ratio between the MCP channel
length to the channel diameter. - The value of a is in common MCP equal to 40.
- The gain of the MCP is controlled by setting the
gain of the camera to certain percentage of the
maximal gain that depends on the maximal allowed
voltage. - The maximal voltage of the MCP in Xybion camera
is 890V - In MEIDEX main mission the gain of the Xybion
camera will be adjusted to be G65. This means
that the MCP voltage will be 580V. According to
the gain curves of the MCP with a 40 the
amplification of the Xybion will be 200. - During the calibration process we discovered that
for an increase of 5 in the value of G (from 65
to 75) the amplification is increase by a factor
of 2. - This fact is confirmed by the amplification
curve.
21The MCP - Schematics and Operating Principle
22The MCP - Gain Factor
AMPLIFICATION
23Xybion IMC-201 - Principle of Operation
- Once the electrons leave the MCP they are
accelerated by 6KV to the photoanode. - The photoanode is a P-20 phosphor anode that has
a peak response (radiation) at 550nm. - The photons emitted from the photoanode are
detected by a CCD. At this wavelength the CCD is
less sensitive to temperature changes. - Between the CCD and the photoanode there is a
fiber-optics minifier that reduces the diameter
of the image that comes from the photoanode
(Dia.1) to the size (diagonal) of the CCD
(2/3). -
24Xybion IMC-201 - Principle of Operation
25Xybion IMC-201 - Technical Specifications
CCD Sensor (786H x 493V) RS-170, NTSC (30
frames/sec) Dynamically determined exposure
time 50 ns to 4.0 ms (for rotating filter) in
50 ns steps 10 decades of light level input,
Auto-gated Spectral Response 200-810nm (U Gen II
UV photocathode) Sensitivity not less than
1x10-6 fc (Lumens/ft2) for photopic source (no
filter) 18mm Gen II MCP Intensifier with 30
lp/mm Intensifier gain 0-15,000 luminance gain
(0 to 100 of the maximal gain) in 255
steps P-20 Phosphor Anode (550nm peak
response) Image annotation 1) Date 2)
Time 3) Exposure time 4) Gain 5)
Temperature of the CCD 6) Video frame
(N/A) 7) External event counter (N/A) () For
stationary filer wheel the maximal exposure time
is 33.3 msec. () Overcast night sky have
Illuminance of 1x10-5 to 1x10-4 fc (Lumens/ft2)
26 Xybion IMC-201 - The Command Tree
27Xybion IMC-201 - Command Tree
- The Xybion camera is controlled via a back-panel
key-pad (N/A in MEIDEX) or via RS-232. - The main commands that are delivered to the
camera are shown in the following command tree. - All commands that are shown in frames are
delivered to the camera via the Xybion Command
Display in the PGSC4310 Software (see following
explanations). -
boxes
28(No Transcript)
29Xybion IMC-201 - Full Image layout
1
5
6
Filter Exposure time (msec) Gain () CCD Temp.
(Co) Date (mm/dd/yy) Time (hhmmss) Coded data
2
3
4
30(No Transcript)
31(No Transcript)
32Xybion IMC-201 - Operating Procedures
33Xybion IMC-201 - Operating Procedures
- The Xybion camera is controlled via a back-panel
key-pad (N/A in MEIDEX) or via RS-232. - The main commands that are delivered to the
camera were shown in the following command tree. - These commands will be delivered to the Xybion
camera through the PGSC4130 software by the use
of - The Relay Commanding Display
- The Xybion Command Display
- The Command Generator Display via the line
XYBIONCMD
34Xybion IMC-201 - Switching the camera ON
- The Xybion camera is switched On via the PGSC4130
software by the use of the Relay Commanding
Display - Pointing on the command Xybion-On.
- Pressing the mouse left button.
- A message RELAY5 ON will appear.
- Pressing Xmit button.
- The white dot will turn green
-
35Xybion IMC-201 - Operating The Camera
- To select a command to the Xybion camera, click
on the command name. - Enter the parameter value (if the command has a
parameter). - Click the Xmit button to send the command.
36Xybion IMC-201 - More Operating Procedures
- Commands and their parameter(s) value(s) are
entered manually in the command buffer display. - For example the Configuration of the Date in the
Xybion camera by entering the Month, Day, Year
settings. - Clicking the Xmit button sends the command.
37Xybion IMC-201 - Switching the camera OFF
- The Xybion camera is switched Off via the
PGSC4130 software by the use of the Relay
Commanding Display - Pointing on the command Xybion-On.
- Pressing the mouse left button.
- A message RELAYK5 OFF will appear.
- Pressing Xmit button.
- The white dot will turn white
-
38Sekai RSC-310 CCD
39Sekai RSC-310 CCD - Components and Interfaces
40Sekai RSC-310 CCD - Operating Procedures
41Sekai RSC-310 CCD - Operating Procedures
- The Sekai camera is controlled via commands that
are delivered to the camera through the PGSC4130
software by the use of - The Relay Command Display
- The Sekai camera operates without any additional
command after it is switched on.
42Sekai RSC-310 - Operating Procedures
- The Sekai camera is switched On via the PGSC4130
software by the use of the Relay Commanding
Display - Pointing on the command Sekai-On.
- Pressing the mouse left button.
- A message RELAYK4 ON will appear.
- Pressing Xmit button.
- The white dot will turn green
43Sekai RSC-310 - Operating Procedures
- The Sekai camera is switched Off via the PGSC4130
software by the use of the Relay Commanding
Display - Pointing on the command Sekai-Off.
- Pressing the mouse left button.
- A message RELAYK4 OFF will appear.
- Pressing Xmit button.
- The white dot will turn white
44Sekai ADVCR-101
45Sekai ADVCR 101 - Components
46Sekai ADVCR 101- Basic Interfaces
47Sekai ADVCR-101 - Operating Procedures
48Sekai ADVCR-101 - Operating Procedures
- The Sekai ADVCR-101 is controlled via commands
that are delivered to the camera through the
PGSC4130 software by the use of - The Relay Command Display
49Sekai ADVCR-100 - Operation Procedures
- The Sekai ADVCR-100 (1) is switched On via the
PGSC4130 software by the use of the Relay
Commanding Display - Pointing on the command Vcr1-On.
- Pressing the mouse left button.
- A message RELAYK1 ON will appear.
- Pressing Xmit button.
- The white dot will turn green
- The ADVCR is now in STBY mode.
50Sekai ADVCR-100 - Operation Procedures
- The Sekai ADVCR-100 (1) is switched to Record
mode via the PGSC4130 software by the use of the
Relay Commanding Display - Pointing on the command Record1-On.
- Pressing the mouse left button.
- A message RELAYK2 ON will appear.
- Pressing Xmit button.
- The white dot will turn green
51Sekai ADVCR-100 - Operation Procedures
- The Sekai ADVCR-100 (1) is switched to Stop
Record mode via the PGSC4130 software by the use
of the Relay Commanding Display - Pointing on the command Record1-Off.
- Pressing the mouse left button.
- A message RELAYK2 OFF will appear.
- Pressing Xmit button.
- The white dot will turn white
- The ADVCR is no in the STBY mode
52Sekai ADVCR-100 - Operation Procedures
- The tape in the Sekai ADVCR-100 (1) is now
Unthreaded via the PGSC4130 software by the use
of the Relay Commanding Display - Pointing on the command Unthrd1-On.
- Pressing the mouse left button.
- A message RELAYK3 ON will appear.
- Pressing Xmit button.
- The white dot will turn green
-
53Sekai ADVCR-100 - Operation Procedures
- The Sekai ADVCR-100 (1) is switched Off via the
PGSC4130 software by the use of the Relay
Commanding Display - Pointing on the command Vcr1-Off.
- Pressing the mouse left button.
- A message RELAYK1 Off will appear.
- Pressing Xmit button.
- The white dot will turn white
54Sekai ADVCR-100 - Operation Procedures
- The Unthread Relay has to be restored to its
initial position. This is done via the PGSC4130
software by the use of the Relay Commanding
Display - Pointing on the command Unthrd1-Off.
- Pressing the mouse left button.
- A message RELAYK3 Off will appear.
- Pressing Xmit button.
- The white dot will turn white
55Vibration Tests
56Instrumentation - Vibration Tests
- Random Vibration Qualification Level (CARS Table
3.6) - Xybion Camera with lens and baffle were vibrated
to CARS Qualification Levels - Sekai Camera with lens were vibrated to CARS
Qualification Levels - All three Sekai ADVCR were vibrated to CARS
Qualification Levels - Test was at NASAs facility
57Instrumentation and Avionics on LEP
58(No Transcript)
59END Crew Tutorial - Instrumentation