Title: Totally Integrated Power
1Totally Integrated Power
- The Portfolio at a Glance
2The System Environment an Integrated Offer
3Integrated Solutions for Power Distribution from
Medium Voltage to the Wall Outlet
1 Medium-Voltage Switchgear 2 Transformers 3 Busba
r Trunking Systems 4 Low-Voltage
Switchgear 5 Subdistribution Boards 6 Circuit-Brea
kers 7 Switch-Disconnectors/in-line 8 Low-Voltage
Circuit Protection
9 Switches and Outlets 10 Energy
Automation 11 Power Management 12 Medium-Voltage
Circuit Protection 13 Building Management
Systems 14 Building Automation 15 Drives
Overview
15
14
TotalBuildingSolutions
11
11
12
13
9
8
8
7
6
Totally Integrated Automation
5
4
4
2
1
5
9
1
2
4
3
3
41 Medium-Voltage Switchgear
- The main task of a medium-voltage switchgear
station is safe and economical power
distribution. Power utilities, industrial
applications or power plants - every operator has
different demands of medium-voltage switchgear
depending on the process-specific requirements. - This includes a high degree of reliability,
safety of operating personnel, and low space
requirements. Other relevant requirements are,
besides appropriate voltage levels, air- or
gas-insulated switchgear, scaling according to
independence from ambient conditions,
maintenance-free design, compactness, guaranteed
return of investment, profitability, service
friendliness and flexibility.
Medium-Voltage Switchgear
5 SIMOPRIME
Air-insulated, metal-enclosed, metal-clad medium
voltage switchgear up to 24KV from SIEMENS
62 GEAFOL Transformers
- Wherever distribution transformers must be
prepared for an utmost degree of safety,
especially in the immediate vicinity of people,
GEAFOL transformers make the perfect solution,
e.g. in high-rise buildings, hospitals, road and
subway tunnels, offshore and mining facilities
etc. - High degree of operating safety
- Long service life
- Rated for 50 kVA to 30 MVA with operating
voltages of up to 36 kV - Low flammability, self-extinguishing, no toxic
gas emission in case of fire - Long service life due to freedom from partial
discharges up to twice the rated voltage - Vacuum-cast high-voltage winding
- Very good electrical, mechanical and thermal
properties - High level of environmental compatibility
GEAFOL Transformers
7SIMARIS design Dimensioning Software
- Easy, fast and safe planning
- Networks in power distribution systems for
industrial, commercial and institutional
buildings can be calculated and dimensioned with
a minimum of manual work involved. - Short-circuit calculation
- Load flow calculation
- Voltage drop calculation
- Selectivity evaluation
- Fast and technically safe selection of the right
protection devices - Dimensioning in compliance with IEC standards
Dimensioning Software
83 SIVACON 8PS Busbar Trunking Systems (1)
- Safety plus
- High short-circuit strength and low fire load
- Increased planning reliability
- Greater profitability
- Low space requirements
- Straightforward network configuration
- Fast installation
- Easy retrofitting in case of on-the-spot changes
of locations and connected loads of equipment - Better integration
- Complete current range from 25 A to 6,300 A for
craft shops, office buildings and production
halls - Communication-capable components
- Connection to SIVACON switchboards
Busbar Trunking Systems
93 SIVACON 8PS Busbar Trunking Systems (2)
System Overview
CD-K System
BD2 System
LX System
- For the power supplyof lighting systems
andsmall equipment inshopping centers,
logisticwarehouses and buildings - of all kinds.
- For power transmissionand distribution in office
buildings and power transfer in all industrial
areas.
- For power transmissionand distribution of high
currents in large buildings, radio stations, data
centers,and for chip and semi- conductor
production.
Busbar Trunking Systems
BD01 System
LD System
LR System
- For the power supply ofelectric tools in
workshops as well as for lighting systems.
- For power distribution and
- and transmission in trade fair buildings, the
automotive industry, heavy industry and on ships.
- For the transmission of large
- energy quantities und harsh ambient conditions,
for the supply of tunnels, or for networking
building parts outdoors and for the power
transmissionin the chemical industry.
103 SIVACON 8PS Busbar Trunking Systems (3)
Busbar Trunking Systems
114 Low-Voltage Switchgear (6)
- SIVACON 8PT
- Integrated safety Type test, arcing fault and
earthquake tests as proof of safety and quality - High degree of flexibility for marine and
offshore applications - High degree of flexibility and economic
efficiency thanks to a great variety of
combinations - Improved profitability - integrated solutions for
low-voltage power distribution thanks to
type-tested interfacing to busbar trunking
systems - High system availability - full communication
capability with PROFIBUS DP - High degree of flexibility thanks to local
SIVACON Technology Partners around the globe - Mainly for technical infrastructure applications
Low-Voltage Switchgear
124 Low-Voltage Switchgear (7)
- SIVACON 8PT - technical data
Low-Voltage Switchgear
135 ALPHA Distribution Boards (1)
ALPHA 125 Universal
- ALPHA wall-mounted distribution boards
- Used as main and sub-distribution boards in
institutional, commercial and industrial
buildings - In DIN standard ALPHA 160 , ALPHA 400, ALPHA 630
- In NF standard ALPHA 125, ALPHA 630
- Distribution boards and their components are
modularly designed - Well-matched systems solutions ranging from
assembly kits to floor-mounted distribution
boards - Boards available with sheet-steel or transparent
doors
ALPHA 400 DIN
ALPHA 630 DIN
Subdistribution Boards
For electricians and switchgear panel builders
ALPHA SELECT software enables fast
configurations of distribution boards and meter
cabinets.
146 SENTRON Circuit-Breakers (1)
- SENTRON 3VL molded-case circuit-breakers
- High degree of flexibility thanks to modular
design - Molded-case circuit-breakers for easy
installation, retrofitting and extension - All-round compatible accessories
- Greater system transparency owing to
communication capability - Direct interfacing to PROFIBUS DP via Com10
module - Easy access to Ethernet/Internet using BDA Plus
for remote diagnosis and parameterization - Full transparency with power management
- Areas of application
- As feeder or outgoing circuit-breaker in
distribution systems - As switching and protective devices for motors,
transformers and capacitors - As main switch and EMERGENCY STOP switch in
connection with lockable, rotary operating
mechanisms and terminal covers
Our 3VL molded-case circuit-breaker is the
universal solution As components for
distribution boards, the product series from 16 A
to 1,600 A excels by its tremendous versatility
and its space-saving, compact design. Matching
releases are available as thermo-magnetic (16 A
to 630 A) and electronic versions (63 A to 1,600
A) and the whole product range is complemented
by merely two design families of internal
accessories.
Circuit-Breakers
156 SENTRON Circuit-Breakers (2)
- SENTRON 3WL air circuit-breaker
- High degree of flexibility thanks to modular
design - Easy circuit-breaker retrofitting and extension
on site - Very few components for a multitude of functions
in any application - Greater system transparency owing to
communication capability - Direct interfacing to PROFIBUS DP via Com15
module - Easy access to Ethernet/Internet using BDA Plus
for remote diagnosis and parameterization - External processing of messages / measured values
via CubicleBUS module - Full transparency with power management
- Areas of application
- Suitable as incoming-feeder, distribution,
outgoing-feeder switch and tie breaker in
electrical installations - To switch and protect motors, capacitors,
generators, transformers, busbars and cables - Suitable for use as EMERGENCY OFF switch in
combination with an EMERGENCY OFF mechanism (
DIN VDE 0113, IEC 60204-1)
3WL air circuit-breakers are extremely flexible.
With just three different sizes, they cover a
performance range from 630 A to 6,300 A. This
makes them uncompli- cated for use in many
applications - everywhere in the world. In
addition to circuit-breakers which comply with
IEC standard 60947-2, there are also models with
UL 489 and UL 1066 approval. All models feature
the same design, the same handling, and the same
mechanical accessories. And the result unique
planning reliability and a host of application
possibilities worldwide.
Circuit-Breakers
167 SENTRON Switch-Disconnectors (1)
- Our wide product range of SENTRON
switch-disconnectors and their versatile
accessories ensure reliable disconnection and
switching under load, plus proven,
top-performance protection against overload and
short circuits. With or without fuse SENTRON
switch-disconnectors are easy to use and
retrofit. - Proven technology a million times over
continuously developed to suit requirements that
arise in practice - Be on the safe side with every application from
line protection to personal safety - Easy, practical and time-saving handling
- Uncomplicated integration into general solution
concepts for low-voltage power distribution
Switch-disconnectors
178 BETA Low-Voltage Circuit Protection (1)
- BETA protecting
- Miniature circuit-breakers
- For the protection of indoor plants, for
industrial applications and as a main switch for
the disconnection or safety isolation of systems.
- According to the relevant IEC standards, devices
hold a worldwide approval for power systems up to
250/440 V AC. - For special applications and for plant
construction, miniature circuit-breakers may be
equipped with add-on components, like auxiliary
current switches, fault signal switches, shunt
releases, undervoltage releases and RCD modules. - Residual-current-operated protective devices
- RCCBs of type A (pulse-current sensitive) are
normally used in Germany type AC (AC-current
sensitive) in South European countries, for
example. - SIQUENCE, type B, AC/DC-sensitive RCCBs also
detect smooth DC fault currents besides fault
current types A - smooth DC currents as they
would occur in networks with frequency converters
for drives. - Super-resistant RCCB, preventing accidental
disconnections by short-time delayed tripping of
the RCCB. Short-time pulsating discharge currents
often occur, when capacitors are switched in.
Low-Voltage Circuit Protection
188 BETA Low-Voltage Circuit Protection (2)
- BETA protecting
- Low-voltage fuse systems
- NEOZED, DIAZED and LV HRC fuse systems
are
mainly used in distribution systems and for plant
construction. NEOZED and DIAZED fuse systems can
be handled by technically unexperienced or
uninstructed persons, they are also approved for
household installations. LV HRC fuses are an
important part of the switchgear in utilities
companies. - In South Western Europe, cylindrical fuses are
also used in such applications. - SITOR semiconductor protection fuses protect
power semiconductor devices against the effects
of short circuits, because their super-quick
tripping characteristics respond much faster than
conventional LV HRC fuses. Special design types
provide for customized installation. - Lightning current and overvoltage protection
- Lightning current arresters are categorized
according to lightning protection zones (LPZ).
They are used for device and system protection
against overvoltages and high surge currents
caused by direct or indirect strikes of
lightning.
Low-Voltage Circuit Protection
198 BETA Low-Voltage Circuit Protection (3)
- BETA switching - switches
- ON/OFF switches are used for switching lighting,
motors, and other electrical equipment. ON/OFF
switches with current ratings of 32 A to 125 A
can be applied as switch-disconnectors in
compliance with IEC/EN 60947-3. - Remote-control switches, switching relays and
Insta contactors are standard equipment in
electrical installations, they are preferably
used in residential buildings. They are
particularly suited for switching heating and
lighting systems as well as motors. - Mechanical and digital timers, timers for
stairwell lighting and timing relays are used for
timing electrical functions in buildings and
facilities, being the basis for energy saving.
Low-Voltage Circuit Protection
209 DELTA Switches and Outlets (1)
- Overview of the product range
DELTA line - the switch range to express your
style by ultra-modern forms
DELTA vita - a host of variations for setting
individual color accents
DELTA style - the design series that combines
elegance with modern look
DELTA miro glass - clear
switchdesign with frames made of glass
Switches and Outlets
DELTA miro Holz - sets design accents with real
wood
DELTA miro Color - makes exclusive design a
standard
DELTA profil - the switch range that
communicates harmony in shape and color
DELTA natur - the switch range that couples a
sleek design with fine woods
suitable for Siemens GAMMA instabus
2111 Power Management using SIMATIC powercontrol
- Reduction of operating costs
- By making power consumption and system status
transparent - Reduction of energy consumption
- By promoting energy-conscious behavior, since
energy-cost awareness is sharpened by allocating
consumption incurred to those cost centers
responsible for it - Increased system availability
- Anomalous operating states are detected in good
time and thus remedied early - Efficient engineering
- Thanks to parameterizing instead of programming
The power management software SIMATIC
powercontrol features a modular concept. As a
basic software it provides transparency of the
energy flows, presenting load curves and
information on the system status. The extension
module SIMATIC powercost takes care of the
allocation of energy consumption/cost to cost
centers.
Power Management
More safety, lower costour modular power
management software
22Thank you for your attention!