Title: Diapositiva 1
1(No Transcript)
2Maintenance decanter
Decanter with hydraulic transmission Replace the
suction filter
Remove the cover
3Decanter with hydraulic transmission Replace the
return filter
4Greasing the gear reductor
Remove the tap
Greasing
5Gearbox oil lubricated
Remove tap and empty
Gearbox oil reservoir
6Greasing gearbox with oil circulation
Top cap
Bottom cap
7Top cap
Decanter with hydraulic transmission, change
hydraulic oil
Bottom cap
Level indicator
8Greasing mechanical parts
Grease nipple
Grease nipple
Grease nipple
9Lubricants table
10Decanter with fixed speed Adjustment sensors
drum/scroll
Check sensors
Sensor distance in mm
11Decanter with hydraulic transmission Replacing
the sensors of the hydraulic motor
Notch on the sensor
12Remove cover
E 10- 15 mm max
Remove the pump plate
Remove the screw belt before removing the drum
belt
Replace drum belts
Remove screws in sequence
Decanter with hydraulic transmission Replacing
the drum belts
13Remove cover
Replace scroll belts
Remove screws in sequence
E 10- 15 mm max
Decanter with hydraulic transmission Replacing
the scroll belts
14Remove cover
Replace belts
Loosen the screws in sequence
E 10- 15 mm max
Decanter with fixed speed. Changing the belts
15Regulating the weir level
solids
centrate
centrate
centrate
solids
centrate
solids
Solids too wet Increase D
solids
Centrate dirty Decrease D
16Regulating the level
Open the door and lift
Ruotare i livelli
Example CD 25
17Adust the water level in relation to the oil level
Width
Water level
Oil level
Lift out
Regulating the weirs for a 3-phase decanter
18Cleaning the outside of the drum
Open covers
Detach the feed hose connection
19(No Transcript)
20Maintenance schedule
21(No Transcript)