Title: General Mass Spectrometry in the Cores
1General Mass Spectrometryin the Cores
David M. Smalley
2Mass Spectrometer System
Protein Sample
Sample prep
Mass Analyzer Separates ions
Data System
Detection Device
Bioworks Excalibur SEQUEST Mascot In-house
TOF Quadropole Ion Trap FT (ICR) MS
MALDI ESI
34 Mass Spec Instruments
- Applied Biosystems Voyager-DE Pro
- Thermo Electron Corp. LTQ
- Thermo Electron Corp. LTQ-FT
- Applied Biosystems QStar Elite
4Voyager-DE Pro
MALDI-TOF
Ion Source - MALDI Matrix Assisted Laser
Desorption Ionization Mass Analyzer - TOF
Time of flight
5Ion Source MALDI(Matrix Assisted Laser
Desorption Ionization)
Sample
matrix material (benzoic acid derivative)
Laser
Ionized Peptides
6Voyager-DE Pro
Sample
Matrix (benzoic acid derivative)
Spot on a plate
Release of Ions (1 charge)
Let dry
Laser
Place into instrument
7Analyzer is a TOF or Time-of-Flight
Ion Detector
Flight Tube
Laser
V
Ion Source
8Peptide Mass Fingerprinting
MALDI-TOF
Cut out
Trypsin Digestion
Peptide Mixture
Albumin
585 amino acids
22 peptides (10 plus amino acids)
9(No Transcript)
10MALDI-TOFApplications
- Samples
- Peptides Provides MW (high resolution)
- Protein Provides a MW (low resolution)
- Applications
- Protein Mass Fingerprinting
- Quality control for synthetic peptides
- Others. (Recombinant protein, cleavage sites,
kinetic assays, protein modifications, etc.)
11Advantages/Disadvantages
- Advantages
- Quick and easy
- Inexpensive
- High Throughput
- Disadvantages
- Limited Structural Information
- For Peptide Mass Fingerprinting
- Protein must be pure
- Better for yeast or E. coli
- Problem with contamination.
124 Mass Spec Instruments
Mass Analyzer
Ion Source
- Voyager-DE MALDI single TOF
- LTQ ESI tandem
- LTQ-FT ESI tandem
- QStar Elite ESI tandem
13ESI Electrospray Ionization
to mass analyzer
Peptide solution
V
LC
14Single Stage MS
Scan Mode
Mixture of Peptides
Ion Source
MS1
Scanning
Ion Intensity
Mass/charge (m/z)
15Tandem MS
Peptides
Ion Source
MS1
1 peptide
Fixed (on one m/z)
Collision Cell
Fragments of peptide
MS2
Scanning
16ACDECAGH K ACDECAG
HK ACDECA
GHK ACDEC AGHK ACDE
CAGHK ACD ECAGHK AC
DECAGHK A CDECAGHK
ACDECAGHK
17Tandem MS
Peptides
Ion Source
MS1
1 peptide
Fixed (on one m/z)
Collision Cell
Fragments of peptide
MS2
Scanning
18Tandem MS (Can be tandem in time)
Ion Trap
- Selects 1 peptide
- Fragments that peptide
- Determines the m/z for the fragments
Peptides
Ion Source
194 Mass Spec Instruments
Mass Analyzer
Ion Source
- Voyager-DE MALDI single TOF
- LTQ ESI tandem LIT
- LTQ-FT ESI tandem LIT-FT
- QStar Elite ESI tandem qTOF
20LTQ
- LC-ESI-ion Trap
- Ion Trap Tandem in time
Explain MSn
protein mixture
Trypsin Digestion
MS MS2 MSn
LC/ESI
peptide mixture
Ion Trap
Figure from Schwartz, Michael W. Senko and John
E. P. Syka, Journal of the American Society for
Mass Spectrometry, 13(6)659-669 (2002).
21MSn
Peptides
Ion Source
MS1
1 peptide
Fixed (on one m/z)
Collision Cell
Fragments of peptide
MS2
Scanning
Collision Cell
Ion Intensity
MS3
Fragments of fragments
200
100
150
50
m/z
22LTQ
- Strengths
- Excellent throughput
- Good Sensitivity
- MSn capabilities
- Robust
- Weaknesses
- Poor mass accuracy/ low resolving power
- Weak for quantification
- Poor for detection of modifications
- Not well suited for iTRAQ
23LTQ-FT
- LTQ with another ICR analyzer
- Allows for excellent mass accuracy and resolving
power - Better dynamic range than the LTQ
- Also, much more expensive
24QStar
- LC-ESI - Quadropole TOF (QqTOF)
25QStar
- Good mass accuracy and resolving power
- Good dynamic range
- Better for quantification
- iTRAQ and phosphorylation
26Summary
- Explained the major components of a mass
spectrometry system - Described the mass spectrometers in the MS core
in sufficient detail for today's talks.