1
CORRELATION BETWEEN RADIATED IMMUNITY AND
COUPLING ATTENUATION Michiel Pelt
2
Introduction
  • Need for new test method
  • No test methods to measure
  • symmetrical cables, connecting hardware / cable
    assemblies
  • balance at higher frequencies
  • combined effect of balance and screening

3
Introduction
  • Coupling attenuation
  • New and easy test method to evaluate the EMC
    performance of channels and components
    (symmetrical screened)
  • Standard prepared by CENELEC TC 46X / WG3 EN
    50289-1-6
  • Under discussion in ISO / IEC JTC1 SC25 WG 3 and
    CLC TC 215 WG 1

4
Introduction
  • A near field measurement

5
Introduction
  • Simplifications
  • Device under test
  • unshielded twisted pair cable
  • coaxial cable
  • dual foil balanced cable
  • Radiated immunity according to IEC 61000-4-3
  • fixed position antenna and device

6
Coupling attenuation
  • Coupling attenuation

7
Coupling attenuation
  • Definition coupling attenuation

ac 10 LOG10 ( P1 )
max P2n P2f
ac coupling attenuation P1 input power inner
circuit P2n maximum near end peak
power P2f maximum far end peak power
8
Coupling attenuation
  • Limits of coupling attenuation

9
Coupling attenuation
  • Unshielded twisted pair cable

54 dB
10
Coupling attenuation
  • Coaxial cable

52 dB
11
Coupling attenuation
  • Dual foil twisted pair cable

86 dB
12
Radiated immunity
  • Radiated immunity
  • Semi-anechoic room (13.2 x 4.7 x 3.0m)
  • Antenna - set-up 3 m
  • Three amplifiers, two antennas
  • 30 - 200 MHz
  • 200 - 500 MHz
  • 500 - 1000 MHz
  • Incident field about 3 V/m (not modulated)

13
Radiated immunity
  • Dimensions cabling set-up

14
Radiated immunity
  • Justification for cabling set-up
  • Testing active equipment with cabling (proposal
    to CISPR G)
  • Features cabling set-up
  • gain / frequency response flat
  • polarization not critical
  • direction not critical
  • (worst case perpendicular to incident field)

15
Radiated immunity
  • Set-up inside semi-anechoic chamber

16
Radiated immunity
  • Set-up inside semi-anechoic chamber

17
Radiated immunity
  • Uniform area of cabling set-up

18
Radiated immunity
  • Field uniformity according to
  • IEC 61000-4-3
  • 16 points over 1.5 m x 1.5 m surface
  • 75 values within 0 - 6 dB of nominal value
  • Field is not constant but uniform
  • ( 83 horizontal 89 vertical)

19
Radiated immunity
  • Average field strength

20
Radiated immunity
  • Unshielded twisted pair cable

-35 dBm
21
Radiated immunity
  • Coaxial cable

-35 dBm
22
Radiated immunity
  • Dual foil twisted pair cable

-70 dBm
23
Conclusions
  • Conclusion 1 Relative agreement
  • Same difference between coupling attenuation and
    induced power for all tested cables
  • For each test method same deviation between
    curves for balanced and unbalanced cables using

24
Correlation
  • Gain of set-up

G(????) 4 ??Af(????) ??
G(????? antenna gain Af(????? antenna
aperture ? wavelength
25
Correlation
  • Unshielded twisted pair cable

26
Correlation
  • Coaxial cable

27
Correlation
  • Dual foil twisted pair cable

28
Conclusions
  • Conclusion 2 Absolute agreement
  • The induced noise power can be calculated using
    the values for coupling attenuation
  • The calculated induced power fits the measured
    powers for all cables

29
Conclusions
  • Errors during correlation
  • Incident field uniform but not constant
  • Gain set-up varies with frequency
  • Coupling attenuation approached by envelope curve
  • ...