Integrity Management Upate - PowerPoint PPT Presentation

1 / 9
About This Presentation
Title:

Integrity Management Upate

Description:

First Operator Qualification Survey. Objective: Show program scope and performance ... Total qualification records, annual 435,074. Average company 16,734 ... – PowerPoint PPT presentation

Number of Views:161
Avg rating:3.0/5.0
Slides: 10
Provided by: paulp163
Category:

less

Transcript and Presenter's Notes

Title: Integrity Management Upate


1
Operator QualificationPublic Meeting December
2005
AGA Operator Qualification Survey Results
2
Operator QualificationPublic Meeting December
2005
  • Program Costs
  • Infrastructure
  • Performance Metrics
  • Regulatory Issues

3
Survey Results
  • First Operator Qualification Survey
  • Objective Show program scope and performance
  • AGA data is from investor owned gas distribution
    and combination utilities
  • 34 companies reported
  • 44.6 million services (74 nation)
  • 64,262 employees (76.5 of nation)

4
Survey Results
Gas Utility Employees (thousands) Total 129 In
vestor Owned 114 Distribution
51 Transmission 25 Integrated
5 Combination 33 Municipals
15 Services 60 Million
5
Annual OQ Program Costs
  • OQ program management cost 19 million
  • 764K ave.
  • OQ managers, trainers
  • evaluators 6.8 FTE ave.
  • Training costs 91 million
  • 4 million ave.

6
OQ Infrastructure
  • Purchased or licensed OQ software 47
  • Computer based training 44
  • Adopted all or part of a commercial
  • OQ program 47
  • Adopted all or part of a commonly
  • used covered task list 56

7
OQ Infrastructure
  • Covered Task Lists Used all or in Part
  • Midwest Energy Association
  • Northeast Gas Association
  • New England Gas Association
  • Pennsylvania Gas association
  • Kentucky Gas Association
  • Safety and Compliance
  • ASME B31Q

8
Performance Metrics
  • Employees OQ qualified 24,415
  • Average task evaluation per employee 29.4
  • Total qualification records, annual 435,074
  • Average company 16,734
  • Annual employee OQ training 28.4 hrs.
  • Percent OQ test failures requiring
  • re-evaluation 2.1

9
Performance Metrics
  • Distribution Incidents Involving Operation Action
  • DOT Database
  • Total Operator Action
  • 2002 113 7 (6.2)
  • 2003 151 6 (4.0)
  • 2004 133 6 (4.5)
  • Sept 2005 114 1 (0.9)

Distribution incident is 5,000 damage, injury,
or release of gas with fire or explosion
10
Regulatory Issues
  • New Construction
  • 23 of 24 survey companies include new
    construction
  • Requalification Intervals
  • One year 13
  • Three years 47
  • Five years 40
  • More than five years 0
Write a Comment
User Comments (0)
About PowerShow.com