Company presentation
2
Who is Brink Climate Systems?
  • The first manufacturer in the Netherlands to
    develop and market air heating systems
  • Applications in dwellings, offices, schools,
    sports centres, showrooms, working spaces and
    distribution centres
  • Brink designs and manufactures all equipment and
    parts in-house
  • Brink Climate Systems has its in-house advice
    department with ample experience in designing air
    heating and ventilation systems
  • European market leader in the field of balanced
    ventilation with heat recovery

3
History
  • Established in Assen, the Netherlands, 1903
  • Move via Meppel to Staphorst, 1958
  • Start production air heating, 1964
  • Introduction first heat recovery unit, 1982
  • Participation in Ned Air, 1998
  • Part of Centrotec, 2002
  • Takeover of Ned Air, 2003
  • Takeover of Innosource, 2005

4
Brink Climate Systems within the holding
  • Stock market quotation
  • Approx. 135 million turnover
  • About 1.000 employees
  • Establishments in 10 countries

CENTROTEC Sustainable AG
  • MEDICAL TECHNOLOGY ENGINEERING
  • GAS FLUE SYSTEMS

CLIMATE SYSTEMS
  • Ubbink Systems (NL, UK, F, B)
  • Centrotherm Abgassystemtechnik (D, I)
  • Möller Medical (D)
  • Centroplast (D)
  • Rolf Schmidt Industri Plast A/S (DK)
  • Centrotec Composites (D)
  • Bond Laminates (25 D)
  • Brink Climate Systems (NL, D)
  • Ned Air (NL)
  • Innosource (NL)

5
Brink Climate Systems
  • Brink Climate Systems B.V.
  • Air heating for residential and non-residential
    building
  • Balanced ventilation with heat recovery
  • Deveko B.V.
  • Installing
  • Golu B.V.
  • Installing
  • Kempair B.V.
  • Installing
  • Ned Air B.V.
  • Air conditioning
  • Innosource B.V.
  • Ventilation

6
General information Brink Climate Systems
  • Number of employees 180
  • 6 of those work for the RD department
  • turnover 22 million euros
  • 20 export

7
Brink's markets
Staphorst
The Netherlands
8
(No Transcript)
9
Product range
  • Comfort, all year round, Brink's motto
  • Appliances and parts are expertly designed and
    produced in-house
  • Brink air heaters and ventilation units are
    available from stock in many capacities and
    versions, including the required systems and
    fittings
  • In the Netherlands they are supplied through your
    installer heat recovery also through
    wholesalers
  • Export through, among others, OEM

10
Air heating
  • Combines heating, cooling, ventilating and
    filtering
  • A system of air ducts and inconspicuous grates
  • As traditional radiators are a thing of the past,
    you are completely free to design your interior
  • The air is continuously refreshed and filtered so
    it remains fresh and unwanted dust particles are
    kept outside
  • The slowly circulating air quickly brings your
    home to the desired temperature
  • High efficiency, so low heating costs

11
Allure, direct-fired, high-efficiency air heater
  • Three different capacities of 4-40 kW
  • With top or bottom outlet
  • Main parts
  • heat exchanger and
  • burner both manufactured from highly
    corrosion-resistant stainless steel that can
    withstand high temperatures and the continuous
    temperature fluctuations

12
SWB-HR, direct-fired, high-efficiency air heater
  • Specially developed for use in mass production of
    houses
  • The slowly circulating air quickly brings your
    home to the desired temperature
  • Continuous ventilation improves the interior
    climate
  • The appliance can excellently be combined with
    heat recovery

13
Elan, indirect-fired, high-efficiency air heater
  • Used when hot water is the energy carrier
    (district heating etc.)
  • Two types Elan 10 and Elan 25, with top or
    bottom outlet
  • The appliance can excellently be combined with
    the heat recovery unit Renovent HR
  • With their matching designs the two appliances
    together look like one

14
Top cooling Allure and Elan 25
  • With their integrated controls they can quickly
    and easily be equipped with top cooling
  • This brings fresh and cool air into your home
    during the day

15
Display air heaters
  • The air heaters come with a display that is used
    to control the appliance
  • In the event of a problem, the cause is indicated
    on the display or on the room thermostat

16
Control Allure and SWB-HR
  • The perfect cooperation between the control unit
    and the electric clock thermostat ensures a very
    stable room temperature
  • A pleasant interior climate is created

17
Grates
  • Only the inconspicuous design grates in the wall
    or floor are visible
  • Various grates available
  • standard grates made of high-quality materials
    in every RAL colour (at a surcharge)
  • aluminium grates satin-gloss, natural-coloured
    finish

18
Balanced ventilation
  • The interior air is refreshed continuously
  • The quantity of air that is carried off is the
    same as the quantity coming in that is
    referred to as balanced ventilation
  • The heat present in the foul air that is carried
    off from the house, is used to heat the fresh,
    clean outdoor supply air
  • Application of heat recovery means that the
    energy of the warm air to be carried off is
    transferred to the fresh, clean outdoor air. That
    results in draught-free and unnoticed ventilation
    at only 10 of traditional ventilation costs
  • 95 of the heat is preserved

19
Renovent HR, balanced ventilation with heat
recovery
  • Two types M(edium) and L(arge) in three
    versions, with maximum capacities of 300 and 400
    m3/h respectively
  • Self-adjusting constant flow fans
  • The energy-saving direct current fans only use
    50 of the energy that traditional fans use
  • Efficiency of 95
  • Settings display

20
Options and possibilities Renovent HR
  • Optional wireless remote control
  • Both low-voltage and perilex
  • 100 bypass (available ex factory)
  • Made-to-measure ventilation
  • 3-way switch with filter indication (see photo)
  • Pollen filter

21
Heat exchanger
  • The synthetic heat exchanger (PETG) transfers
    more than 95 of the heat, which makes further
    heating of the ventilation air superfluous
  • The EPC contribution is approx. 0.3
  • With their specific shape the synthetic blisters
    ensure that the air flows remain separated
    optimum heat exchange

22
Bypass unit for night ventilation
  • In summer the bypass unit for night ventilation
    ensures that cool night air replaces in so far as
    possible the interior air that has been heated
    during the day, resulting in a pleasant interior
    temperature
  • This system is activated automatically, dependent
    on the interior and exterior temperatures the
    occupant does not have to do a thing

23
Constant filtering
  • The standard filters remove 95 of the dust
    particles from the air
  • The (electronic) pollen filter removes
    practically all particles (99) from the air such
    as pollen, fungi, tobacco smoke and germs
  • The (electronic) pollen filter is an excellent
    solution for people with allergy problems

24
Air heating with balanced ventilation
  • The advantages of both air heating and balanced
    ventilation with heat recovery in one system.

25
Flair, free-blowing air heater
  • Developed for heating small to large working
    spaces
  • Available in Flair IGB Basic and Flair IGX
    Comfort in various capacities
  • The appliance outlet can be moved from front to
    bottom by exchanging the bottom plate with the
    outlet grill
  • Constant circulation of heated air

26
Circulation unit
  • The circulation unit supports the Flair air
    heater
  • The unit ensures that in very large, well
    insulated rooms the circulation rate is
    maintained, keeping the gas consumption lower

27
(No Transcript)
28
Address information Brink
  • Brink Climate Systems B.V. Postbus 24 7950 AA
    Staphorst R.D. Bügelstraat 3 7951 DA Staphorst
    Phone 31 522 46 99 44 Fax 31 522 46 94 00
    info_at_brinkclimatesystems.nl www.brinkclimatesyste
    ms.nl
  • If you have a specific question, please send an
    e-mail message to the relevant department
    procurement inkoop_at_brinkclimatesystems.nl
    sales verkoop_at_brinkclimatesystems.nl
    service service_at_brinkclimatesystems.nl
    documentation documentatie_at_brinkclimatesystems.nl
    design advice ontwerpadvies_at_brinkclimatesystems
    .nl

29
(No Transcript)
Write a Comment
User Comments (0)
About PowerShow.com