Measuring Caloric Intake Using Chewing Sounds - PowerPoint PPT Presentation

1 / 1
About This Presentation
Title:

Measuring Caloric Intake Using Chewing Sounds

Description:

The goal of the project is to create a device capable of monitoring chewing sounds. ... Maxim Integrated Products. 2006 Crunching FFTs with Microsoft Excel. ... – PowerPoint PPT presentation

Number of Views:160
Avg rating:3.0/5.0
Slides: 2
Provided by: bryanm7
Category:

less

Transcript and Presenter's Notes

Title: Measuring Caloric Intake Using Chewing Sounds


1
Measuring Caloric Intake Using Chewing Sounds
Jimmy Fong (Co-Leader), Matt Valaskey
(Co-Leader), Aditi Bharatkumar (Communications),
Bryan Mounce (BWIG), Vidhya Raju (BSAC)
The goal of the project is to create a device
capable of monitoring chewing sounds. Analysis
of this data will recognize types of foods eaten.
  • In-Ear Circuit Design
  • Combination of proposed design ideas
  • - based on custom amplifier circuit design
  • - is the most cost-effective
  • - requires microphone to be inserted in ear
    canal
  • - closest to highest region of bone conduction
    (maximal exposure to chewing sounds)
  • - optimal insulation from ambient noise
  • In-ear probe microphone design
  • - places microphone in ear canal
  • External microphone design
  • - mastoid process
  • - throat
  • - behind ear
  • Custom Amplifier Circuit Design

Audioscan Professional Audiology Microphone and
Amplifier
Amplification with a Custom Circuit Board
Spectral Analysis in Matlab
FFT Analysis in Excel
Final Circuit Board Amplifier and Microphone
Earpiece
  • Collection of preliminary chewing sound data from
    different microphone locations
  • Analysis and evaluation of signal quality based
    on microphone location in-ear microphone optimal
  • Recording of chewing data
  • Analysis of collected data using Excel and
    Matlab Excel analysis superior
  • Construction of an economical circuit-board design

The acoustic properties of chewing as measured in
the ear canal
  • The microphone should
  • Have a frequency response of 20 Hz to 20000 Hz
    to ensure that all chewing sounds are recorded.
  • Reproducibly record chewing.
  • Analysis of Data should
  • Distinguish between chewing frequencies and
    normal speech/ambient noise frequencies
  • Possibly reveal a correlation between chewing
    frequency and caloric intake
  • Ergonomics
  • Device should fit comfortably in the ear and
    should be minimally intrusive
  • Hygiene should not be compromised probe tubes
    for the microphone should be disposable
  • Cost should not over exceed the benefit of the
    device.

Further investigation will include further
testing of the correlation between peak frequency
and type of food consumed. In addition, a
portable version of the device will be developed.
The in-ear circuit design will aid in tracking
dietary intake with the greatest accuracy.
Manufacture of First Microphone
Early Circuit Board Construction
National Institute of Health Statistics.
http//win.niddk.nih.gov/statistics/index.htmwhyd
odiffer Amft, O., Stager, M., Lukowicz, P., and
Troster, G. 2005. Analysis of chewing sounds
for dietary monitoring. Lecture Notes in
Computer Science 56-72. Cichero, J. A. and
Murdoch, B. 2002. Acoustic signature of the
normal swallow characterization by age, gender,
and bolus volume. Ann Oral Rhinol Laryngol 111
623-631. Doctronics Education Publishing. 2006.
http//www.doctronics.co.uk/scope.htmaudio Maxim
Integrated Products. 2006 Crunching FFTs with
Microsoft Excel. http//www.maxim- ic.com/appnotes
.cfm/an_pk/3292
Microphone Sounds Displayed on an Oscilloscope
Initial Computer and Technical Analysis
Write a Comment