Power and Energy Management for Savings and Productivity PowerPoint PPT Presentation

presentation player overlay
1 / 26
About This Presentation
Transcript and Presenter's Notes

Title: Power and Energy Management for Savings and Productivity


1
Power and Energy Management for Savings and
Productivity
  • PRESENTED BY
  • Ecologicx First
  • 954-384-1544
  • Authorized Agent, an Authorized Dealer of
    Circuit Rider Marketing, LLC

Ecologicx First 954-384-1544 www.ecologicx.com
2
About Ecologicx First
  • We are an Energy Management Company-
  • We help our customers manage their energy
  • costs by reducing their spending on their
  • fuel costs and their electricity bills,
  • guaranteed!
  • Dont let your energy bills go from bad to
  • worsefor real savings call Ecologicx First

Ecologicx First 954-384-1544 www.ecologicx.com
3
Electricity Savings with CR Max System
  • Ecologicx CR Max System
  • is custom designed and integrated to
    your existing facility, providing you
    with electricity savings and protection of your
    entire property.
  • is turnkey and requires no shutdown of your
    operations.

Ecologicx First 954-384-1544 www.ecologicx.com
4
Benefits of CR-Max System
  • Utility Bills
  • Reduce kWh Energy Charges
  • (Guaranteed 10 or 6 months money back)
  • Reduce Demand Charges more than 10
  • Prevent Power Factor Tariffs
  • End-Use Equipment
  • Provides 100 down-line lightning and surge
    protection
  • Reduces harmonics in your electrical wiring
  • Improved productivity of personnel and equipment
    by reducing electric faults
  • Reduced maintenance
  • Increased life of electronics, motors, lighting
    and transformers

Ecologicx First 954-384-1544 www.ecologicx.com
5
Purpose/Mission
  • The Circuit Rider exists to
  • reduce energy costs while
  • preventing and solving power quality problems.
  • The Circuit Rider meets customer requirements by
    consulting on
  • industry best practices
  • state of the art power conditioning
  • at costs below non-competitive technology
  • with a return on investment between 9
    months and 2 years.

Ecologicx First 954-384-1544 www.ecologicx.com
6
Contributors to High Energy Costs
  • Old infrastructure
  • Increased electric demand
  • Power factor tariffs in some markets are
    increasing costs from a few per cent to over 35
  • _ In some cases it is hidden in your bill
  • Related power costs are rising
  • Utilities fuel and operating costs
  • Reduced performance from power distortions
  • Repairs and replacement
  • to sensitive electronics
  • to motors components and drives
  • related lost productivity

Ecologicx First 954-384-1544 www.ecologicx.com
7
What is a Power Quality Problem?
  • Any occurrence manifested in voltage, current,
    or frequency deviations that results in
  • failure or mis-operation of end-use equipment.
    From a Dranetz-BMI Power Quality Seminar

Ecologicx First 954-384-1544 www.ecologicx.com
8
Power Quality Problems
  • Events and Conditions Associated Corrective
    Technology
  • Some devices may not perform well on the
    specified PQ event.
  • Blue - Best devices are well suited
  • Grey - Wide variety in performance.
  • White - Not suited to attenuate this event
  • Some devices can exacerbate the specified event
    or power quality condition
  • Prior to selecting any specific device a
    site-specific survey must be performed with power
    quality analyzers suited for qualifying the
    events in question.
  • Each device must be researched for its capacity
    to treat each specific PQ event.

Ecologicx First 954-384-1544 www.ecologicx.com
9
Harmonics in Power Quality
  • The 5th Harmonic
  • Harmonics are un-useful frequencies of energy you
    pay for which
  • Apply reverse torque to motors
  • Provide no motor force
  • Disrupt electronic performance
  • Overheat components and neutral conductors
    damaging motors, electronics, circuit breakers,
    transformers

Six-pulse Drives 5, 7, 11, 13, 17, 19....
Ecologicx First 954-384-1544 www.ecologicx.com
10
Power Factor
  • Power Factor is one efficiency measurement of
    electric power as it is
  • a) transmitted over power lines and
  • b) processed by end-use consumers.
  • P.F. f (voltage, current, time and phase
    angle)
  • The closer the V-C relationship the more power
    can be transmitted over existing conductors.
  • Slightly below 1.0 (lagging) is better than above
    1.0 (leading)

Ecologicx First 954-384-1544 www.ecologicx.com
11
Power Factor Reducers
  • Common electric motors
  • Motors running at lower than rated load
  • Harmonic frequencies from electronics
  • Transmission lines

Ecologicx First 954-384-1544 www.ecologicx.com
12
Power Factor Tariffs
  • A simple formula increases end-user utility costs
    to incent customers into improving power factor
    efficiency
  • Relates to the Utilities ability to move energy
    efficiently
  • Utility companies power factor costs/savings are
    not noticed at the customers meters
  • Corrected Power Factor CAN increase current and
    kWh

Ecologicx First 954-384-1544 www.ecologicx.com
13
Power Quality Issues
Applying Power Factor Correction in a Harmonic
Environment The use of capacitors has long been
accepted as the most practical solution to low
power factor problems in power systems. Modern
capacitors are a reliable, maintenance free,
inexpensive source of VAR's needed in inductive
circuits to synchronize the voltage and current
waveforms. In the past, the application of
capacitors was straightforward all that was
required was a knowledge of KW (or KVA), existing
power factor and target power factor. In recent
years, however, this practice has been
complicated by the proliferation of nonlinear
loads. The Source of the Problem One of the most
widely used solid state motor controls is the
six-pulse drive. These devices represent a
non-linear impedance to the power source, drawing
a quasi-square wave alternating current rich in
harmonics. For six-pulse drives, the
characteristic harmonics are 5, 7, 11, 13, 17,
19....
Source www.powerdesigner.com
Ecologicx First 954-384-1544 www.ecologicx.com
14
Demand Factor
Is the ratio of the maximum real power
consumed by a system to the maximum real power
that would be consumed if the entire load
connected to the system were to be activated at
the same time. This ratio is generally
calculated over 15-30 minutes and expressed in kW
Ecologicx First 954-384-1544 www.ecologicx.com
15
Surge Protection
  • Did you know.
  • The state of Florida, the lightning capital of
    the U.S. experienced over 300,000 lightning
    strikes in 2002 alone.
  • The electricity flowing within a lightning bolt
    can reach 2 million volts.
  • Electrical storms causes billions of dollars in
    property damage every year.
  • Power surges are one of the main causes of damage
    to A/C systems.
  • The Ecologicx Circuit rider System provides 100
    down-line lightning and surge protection, which
    is backed by a minimum of 2 million dollars
    worth of insurance coverage.

Ecologicx First 954-384-1544 www.ecologicx.com
16
Power Quality Issues
Excellent topics from expert third party
sources http//www.memagazine.org/mepower01/5thha
rm/5thharm.html (Mechanical Engineering
Magazine) The 5th Harmonic discusses the lost
energy of the 3 basic harmonics and the REVERSE
TORQUE applied by the 5th , 11th, 17th
harmonics "Ask any motor person in the world what
happens when you run a motor on the fifth
harmonic," said Isaiah Cox, CEO of Chorus. "They
will tell you it runs in reverse at five times
the speed. It is gospel. http//ecmweb.com/ar/el
ectric_power_factor_correction_3/index.htm
(Electric Construction and Mainten.) Power Factor
Correction and Harmonic Resonance A Volatile
MixElectrical Construction Maintenance, Jun 1,
2003 Capacitors may be meant to correct
problems, but they can also introduce them if
incorrectly specified. Industrial and commercial
customers constantly scrutinize their monthly
electric usage looking for ways to save money.
Installing power factor correction capacitors can
reduce costly penalties imposed by the utility
However, you can't indiscriminately add power
factor correction capacitors to a system without
understanding how their presence will affect the
system. Variable frequency drives (VFDs) for
motors, DC power supplies for computers,
electronic ballasts for fluorescent lighting, and
other nonlinear loads can create harmonics. If
you don't consider the existence of these
harmonic sources and the inductive reactance of
the existing system, you'll create the potential
for harmonic resonance Sidebar A
Self-Correcting Problem? Harmonic resonance is
said to be a self-correcting problem. Most times
capacitor fuses will open, capacitor cans will
fail, or the source transformer fails. Any of
these events will lead to the removal of a
component from the system, eliminating the
resonance condition. However, they're all
undesirable results. In a best-case scenario, the
electrical control equipment acts
erratically. http//www.niagaramohawk.com/busind
/pwrqual/lgci/disrupt.html Outstanding utility
web site discussion of many implications in power
quality problems
Ecologicx First 954-384-1544 www.ecologicx.com
17
Energy Saving Issues
  • How MUCH ENERGY is
  • AVAILABLE to be Utilized Better
  • The typical office environment can attribute 40
    of its energy load to HVAC alone.
  • The U.S.s spends 50-65 of its energy on motor
    loads.
  • Partial short-list of CR-Maxs energy saving
    contributions
  • See file Energy Saving Sources V2.2.doc

Ecologicx First 954-384-1544 www.ecologicx.com
18
Ecologicx First-954-384-1544
19
Why Use the CR-Max System
  • CR-Max guarantees savings
  • CR-Max provides 100 down line lightning and
    surge protection
  • CR-Max provides for an integrated power factor
    and power quality solution
  • -power factor can be stopped at Unity (1.0)
    among CR-Maxs unique PQ contributors
  • CR-Max is a more diverse PQ solution than
    capacitors and has no known genuine competitors
    in either performance or customer assurances

Ecologicx First 954-384-1544 www.ecologicx.com
20
How Does It Work?
  • Circuit Rider combines 6 proven technologies
  • Power factor correction
  • Line filter conditioning
  • Noise suppression
  • Surge Protection
  • Voltage balancing
  • Demand factor reduction
  • As well as other new technologies, that are the
    secret ingredients, which are patent pending

Ecologicx First 954-384-1544 www.ecologicx.com
21
Some Facts about the Circuit Rider
  • First manufactured and installed commercially in
    1992
  • 14 year track record of protecting residential
    and commercial properties
  • Documented savings in kilowatt hours used have
    ranged from 10 to in excess of 35

Ecologicx First 954-384-1544 www.ecologicx.com
22
More on Circuit Rider
  • The units are compact ranging from a size of 6
    ½x3x2 for residential units to 10x10x8 for
    larger 3 phase units.
  • Encased in rain tight commercial grade PVC
    containers
  • UL 1449-second edition rating with Canadian
    Endorsement
  • A licensed electrician must install the units
  • Each unit comes with a 5 year standard warranty
    and optional extended warrantees
  • Each unit carries a 2 million product liability
    insurance

Ecologicx First 954-384-1544 www.ecologicx.com
23
Warranty and GuaranteeCustomer assurances for
complete satisfaction
  • Rebuild America Program (U.S. Department of
    Energys EERE) has added Circuit Rider Marketing
    as a business partner.
  • Energy Star Partner
  • CR-MAX has chosen to partner with Texas Energy
    Partnership of SECO as of 6-21-2002.
  • CR-Max energy-saving devices are UL- certified
    surge protection for your sensitive electronic
    equipment
  • Risk free, 6-month money-back guarantee that you
    will save at least 10 on kWh
  • Up to 5-year 100 replacement warranty
  • 2,000,000 property liability coverage per device
  • 1,000,000 personal liability coverage per device

Ecologicx First 954-384-1544 www.ecologicx.com
24
Site SelectionDeciding which sites to treat first
  • Lowest Power Factor in Tariff Markets
  • Rebate contribution to product cost
  • Highest energy cost i.e., kWh per sq. ft.
  • Largest facility motor/HVAC intensive by floor
    space, ceiling height, etc.
  • Power quality sensitivity requirements
    computers, medical, A/V production studio,
    precision manufacturing
  • Maintenance frequency concerns IT /
    communications / POS, copiers, A/C, machine tools

Ecologicx First 954-384-1544 www.ecologicx.com
25
Lets Get Started!
  • How soon do you want to save?
  • Business case and ROI estimates
  • Power load survey simple fault diagnosis
  • Proposal and Invoice
  • Immediate savings through efficiency and
    productivity
  • Additional Services
  • Power quality study
  • Installation and commissioning or supervision of
    the same

Ecologicx First 954-384-1544 www.ecologicx.com
26
Questions and Answers
Ecologicx First 954-384-1544 www.ecologicx.com
Write a Comment
User Comments (0)
About PowerShow.com