You must complete Work Instruction 5 – Isolating & Removing VDOPS Inlet Hose - PowerPoint PPT Presentation

About This Presentation
Title:

You must complete Work Instruction 5 – Isolating & Removing VDOPS Inlet Hose

Description:

Open sampling port on top of filter stack to remove any vacuum pressure in the system. There shouldn’t be any oil expelled. – PowerPoint PPT presentation

Number of Views:38

less

Transcript and Presenter's Notes

Title: You must complete Work Instruction 5 – Isolating & Removing VDOPS Inlet Hose


1
You must complete Work Instruction 5 Isolating
Removing VDOPS Inlet Hosebefore this Step
2
  • Open sampling port on top of filter stack to
    remove any vacuum pressure in the system. There
    shouldnt be any oil expelled.

3
(No Transcript)
4
  • Gently crack each of the eye bolts on the filter
    stack then undo them. Use a rag to clean around
    the seal lines and stop drips. .

5
(No Transcript)
6
  • Unclip filter and slowly draw oit of filter well
    taking care that the oil drains back into the
    well. Inspect the filter for debris.

7
(No Transcript)
8
(No Transcript)
9
  • Hang the filter bag on a hook over a bucket to
    drip dry before discarding.

10
(No Transcript)
11
  • Fold new filter longwise and lower into filter
    stack. Then clip the filter rim into the top of
    the receptacle.

12
  • Place lid back on the filter stack, centre it and
    evenly tighten the eye nuts and tighten firmy but
    do not overtighten.

13
(No Transcript)
14
  • For more information, visit us

http//www.biokem.com.au/
Write a Comment