Title: Voltage Stabilizer
1Power Point Of Automatic Power Factor Controller
- Owner - Mr.Raj Kumar Dhawan
- Comp.Name- Green Dot India Pvt.Ltd.
- Source- www.greendotindia.com
- Email-Id info_at_greendotindia.com
-
greendotindia._at_hotmail.com - Address- G-9 Hemkunt Tower
/Modi Tower,98, - Nehru
PlaceNew Delhi 110 019
2AN IDEAL SOLUTION for POWER FACTOR CORRECTION
FIRST TIME IN INDIAThis is 3rd Generation of
Development in the APFC Field.Indian Market
till today was exposed to the SECOND GENERATION
units that areRELAY TYPE akin to RELAY TYPE
STABILISERS in Voltage stabiliser field.This is
SERVO TYPE APFC CONTROLLER CONTINUOUSLY
CORRECTING TYPE.This will upgrade your concept
of POWER FACTOR CORRECTION.THE UNBALANCED TYPE
APFC provides IDEAL CORRECTION to INDIVIDUAL
PHASES .This objective advantage is not
possible from RELAY TYPE Power Factor
Panels.Your new purchase CAN BE IN THIS TYPE OF
Panel. Cost wise competitive.
3Automatic power FactorController
- AT EXISTING INSTALLATIONS of RELAY TYPE POWER
FACTOR PANEL installations a SMALL SIZED
UNBALANCED TYPE UNIT will further correct POWER
FACTOR of INDIVIDUAL PHASES by correcting PF
of INDIVIDUAL PHASES from AVERAGE FIGURES of SAY
0.95-0.97 to 1 thus further saving 3-4 on
Electricity Bills.SAY ADD 10 KVAR or 20 KVAR
CONSTANTLY VARIABLE CAPACITORS in INDIVIDUAL
PHASES.You may call us for FURTHER DETAILS.R K
Dhawan 9810117725
4GREEN DOT AUTOMATIC POWER FACTORCONTROLLER
- The innovative character of this APFC controller
can be best - understood from the anomaly with the Voltage
stabiliser - field.There are three STAGES of development
- in the field of VOLTAGE STABILISERS /VOLTAGE
REGULATORS. - The latest is a SERVO TYPE VOLTAGE STABILISER.
- that maintains Voltage of any establishment to
1 or so accuracies. - Earlier 1st Stage was when a Voltage
Regulator of MANUAL ROTARY TYPE was - used to adjust the voltage as is still being done
on Voltage regulators for TV etc. - There is ONE b4,6 or 8 POSITION rotary switch
that is rotated to adjust output - voltage. In 2nd stage of this development, RELAY
- PE STABILISERS like those used with Air
Conditioners etc. came in. There are Steps (
2,3,4 or 5 ) and we call them in the Regulating
Transformers that are Switched ON and OFF to keep
output - voltage to say 10 or so accuracy.In the 3rd
Stage the Servo stabilisers came in that
maintain output voltage accuracy of 1 or so
by using a Motor - Driven Variable Transformer .
5- Green Dot Electric Limited has developed a Variac
Based Power Factor Panel. A Motorised - Variable Transformer ( the Motorised Dimmer Dot )
is used a source of Variable Voltage - that is applied to the required value of
Capacitance rated for 440 Volts or so. The
varying - voltage applied to the Fixed value
capacitance-makes the Fixed value Capacitance to - Continuously Variable capacitance that is used to
correct the Power Factor without steps. - There are no switching of Contactors or
interruption of CAPACITIVE CIRCUITS and thus no - harmonics get introduced. The costly harmonics
filters are also avoided. In case the supply - goes off comes in delay is provided to give
time for discharge of capacitors and then to - start again at zero voltage input from the Dimmer
Dot.
6Voltage Stabilizer
- There is further advantage in our
- system that the power change is proportional to
the square of applied voltage to the - capacitors whereas by comparison to Switching In,
and or out Capacitors the affect is - only to the first power of the capacitor size.
- The Power Factor Sensing relay has been developed
from an advanced Micro Controller that - senses the existing Power Factor rotates the
Variable Transformer forward or backward - increasing or decreasing the output voltage of
the Variable transformer, to provide required - voltage across the capacitor so that the adjusted
the required power factor is always - maintained with respect to ever varying load of
the establishment. The LED Read out panel - of the Relay Box reads Input Voltage adjusted
Power Factor