Title: BMET 323 Slingshot Academy / snaptutorial.com
1BMET 323 Slingshot Academy / snaptutorial.com
2(No Transcript)
3BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 1 Homework Chapter 7
Homework Chapter 7 BMET 323 Week 1 Compare and
contrast the extravascular and intravascular
methods of direct measurements of blood
pressure Describe how the oscillometric method of
blood pressure work. Cite your source of
information.
4BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 1 Lab Requirement Annotation
Week 1 Lab Requirement Annotation 4.1 Use
Simulation 1.Develop a LabVIEW program named
simDataLogger.vi. 2.The program generates a
simulated waveform of 10 Hz at 500 Hz sampling
rate. 3.The data shall be stored in a text file
with each sample on its own line. 4.The stored
data shall not have any clipping (data value
exceeds the maximal value the format may store.)
5BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 2 Homework Problems
Chapter 7 Problems 6 7 6. Design a notch
filter that can remove a 60 Hz noise signal from
an ECG signal. Chapter 12 Problems 6 6. Compare
amplifiers (in terms of amplification, bandwidth,
and noise requirements) in ECG, EEG, and EMG
measurements. Chapter 13 Problems 1 8 1.
Identify and explain the noise in the following
ECG graphs inFigure 13-13.
6BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 3 Homework Problems
End of Chapter 17 Quiz 5 and 7 (pp. 535536) 5.
The main characteristic of an FM modulated
carrier is 7. Name four bio-signals a bedside
monitor is used to monitor End of Chapter 17
Problems 1, 8, and 9 (pp. 536537) 1.Compute the
distance between the bedside monitor and the
central nursing station (CNS), given 8. Discuss
warning devices to be used in intensive care
units.
7BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 4 Homework
BMET 323 Homeworks 4,5,6 Homework 4 2. For
an ideal square-wave defibrillator, determine the
energy delivered to the patient (see Figure
8-11). 3. Given a situation when a fully charged
defibrillator capacitor discharges through the
chest, determine the current (peak) through the
thorax and the voltage drop (peak) across the
thorax.
8BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 5 Homework
BMET 323 Week 5 Homework
9BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 5 iLab Human Thermometer
BMET 323 Week 5 iLab Human Thermometer
10BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 5 iLab
Purposes This lab requires that you use your
circuit skills (aka trouble-shooting) to analyze
what is happening, signal wise, in Figure 1 as a
function of the control switches. Secondly, the
Lab addresses IAs , their uses and critical
operational parameters. Specufically, you will
test the AD620s differential and common mode
voltage gains, its CMRR and use it to process
analog signals of interest.
11BMET 323 Slingshot Academy / snaptutorial.com
BMET 323 Week 6 Homework
HW 6 CH 10 4,6 4. List the types of sensors
in the hemodialysis machine and their placement
in the dialysis circuit. 6.List the main
components of a dialysis machine on the dialysate
side and on the blood side (at least five on each
side).
12(No Transcript)
13BMET 323 Slingshot Academy / snaptutorial.com