Title: Get online BACnet Submeter & Modbus Sub Meters
1Call Us -(888) 928-8663
Get online BACnet Submeter Modbus Sub Meters
Ctlsys practices on the BACnet Energy Meter,
BACnet Energy Submeter. Ctlsys energy meter has
a worked on BACnet communication module
especially expected to monitor and gather
continuous revenue grade electrical data for
building control and computerization
applications. The meter demonstrates various
vitality parameters, for instance, voltage,
ampere, power factor, harmonic bends, vitality
and request information making it ideal for
three-stage, two-phase and single stage systems
to track vitality usage and patterns. The BACnet
Energy sub meter (MS/TP) is a very effective
vitality and power metering answer for
building-automation systems requiring the BACnet
correspondences tradition. The new meter
supplements the Association's Modbus sub meters
and LonWorks sub meters, engaging any
building-automation system steady receptiveness
to electrical estimations including power,
vitality, voltage, current, and power factor.
2Different Features Small frame considers for
basic foundation inside most electrical sheets.
Pluggable screw terminals for straightforward
wiring
0.5 precision ostensible
True RMS control smooth with driving or
slacking power factor and sliced or twisted
waveforms
Measure variable speed drive pumps and motors
Safe CT's (present Transformers), yield 0.333
Vac at evaluated current.
Split center CTs for speedy Foundation
Solid center CTs are more affordable and abstain
from altering
Custom and standard Bus Bar measured CTs
3Modbus Sub-Meter Know that the DTS-310 Modbus
sub-meter is a high accuracy gadget. For best
execution purchase high exactness CTs, for
example, the LNxF Series (0.2), the 4LSF (0.5)
or the SCT-125H (0.5). Precision is just on a
par with the weakest connection. Another famous
choice, but "standard" 1 precision, is to
combine the DTS-310 with one of Magne lab's
Rogowski coils.
Components
Line-controlled single/three stage vitality
sub-meter with auto-topology recognition
Class 0.2 Energy Meter (ANSI C12.20) "š Revenue
grade."œ
Bi-directional for sustainable frameworks (Net
metering)
Multiple Connectivity Options
Embedded Ethernet connectivity alternative for
use with Modbus/TCP, BACnet/IP, SNMP or DNP 3.0
RS-485 connectivity alternative Modbus RTU or
BACnet MS/TP
Communications setting using DIP switches for
Modbus RTU
Color coded, pluggable availability
Compact DIN rail design
User configurable utilizing DTS Config
programming
User-perceptible Modbus enlist region
Sunspec Alliance confirmed
Designed and Manufactured in the USA. Conforms
to Buy American Provisions of ARRA Section 1605
4LonWorks Sub-Meter Know that the DTS-310 LonWorks
sub-meter is a high exactness gadget. You might
need to purchase high precision CTs, for
example, the SCT-075H or the SCT-125H (accuracy
is even good when the connection is weak).
Another prominent choice, yet "standard" 1
accuracy, is to combine the DTS-310 with one of
Magne lab's Rogowski coils.
5Various Features Line-controlled single/three
stage vitality sub-meter with auto-topology
recognition
Class 0.2 Energy Meter (ANSI C12.20) "š
Revenue grade."œ
Bi-directional for sustainable frameworks (Net
metering)
Multiple Connectivity Options
Embedded Ethernet connectivity alternative for
use with Modbus/TCP, BACnet/IP, SNMP or DNP 3.0
RS-485 connectivity alternative Modbus RTU or
BACnet MS/TP
Communications setting using DIP switches for
Modbus RTU
Color coded, pluggable availability
Compact DIN rail design
User configurable utilizing DTS Config
programming
User-quantifiable Modbus enlist zone
Sunspec Alliance confirmed
Continental Control Systems
Add- 2150 Miller Dr, Ste ALongmont, CO 80501
Main (303) 444-7422
Toll Free (888) 928-8663
Fax (303) 444-2903
Sales and Customer Support sales_at_ctlsys.com
Technical Support support_at_ctlsys.com