Title: Early Streamer Type Advance Lightning Protection Systems
1Follow Safety
2 Lightning Strikes Lost of Lives and Assests
A strike can average 100 million volts of
electricity Current of up to 100,000 amperes Can
generate 54,000 oF Lightning strikes somewhere on
the Earth every second Kills Many Lives
3Damage from Lightning Strike on Ground
4Surge Protection Is A Must
5Sikhana to Padega Hi Follow Electrical Safety
6Grid/Earth Mat Design
7 Surge in Systems and Result
8Surge in DC Application
9(No Transcript)
10Copper Cladded Conductor For Electrical
Installation
The Copper Clad Steel Grounding Conductor is made
up of steel with the coating of 99.99 pure
copper. These conductors/ wires or strands are
equipped with the strength of steel with the
conductivity and copper with the better corrosion
resistance property. The concentric copper
cladding is metallurgic ally bonded to a steel
core through a continuous, solid cladding
process using pressure rolling for primary
bonding. The copper cladding thickness remains
constant surrounding steel. We use different
steel grades for the steel core result in Dead
Soft Annealed, High strength and Extra High
Strength Characteristics. The Copper Clad Steel
Wire yields a composite conductivity of 21, 30
and 40 IACS, and available in Annealed and Hard
drawn. We are delivering products with varied
conductivity and tensile strength as per the
customer need. Further, the wire can be processed
to be silver plated or tinned copper clad steel
wire.
11Most Efficient JointProcess
It is efficient and superior to all existing
surface to-surface mechanical retention
connectors.
12What is Exothermic Welding System?Copper to
Bi-Metal and Alumenium
- Types of Exothermic Joints
- Possible to join any bi metal except aluminum
- Exothermic welding is a process of making
maintain free highly molecular bonding process is
superior in performance connection to any known
mechanical or compression-type surface-to-surface
contact connector. Exothermic weld connections
provide current carrying (fusing) capacity equal
to that of the conductor and will not deteriorate
with age. - It offers Electrical connections between two or
more copper to copper and copper to steel
conductors. - Highly portable method as it does not require
any external power source or heat source, so it
can be done almost anywhere. - It provides strong permanent molecular bond
among metallic conductors that cannot loosen and
further will not deteriorate with age. - Connection does not corrode with time and it
offers permanent conductivity.
13Early Streamer Lightning Protection(1) Advance
Systems for ProtectionNFC 17-102
14Early Streamer Lightning Protection(2) Advance
Systems for ProtectionNFC 17-102
15Standards Worldwide
- This page provides information on the main
standards (and technical régulations) in use
worldwide.
16IEC Declaration by CENELEC for NFC17-102
17BT has confirmed that ESE National Standards
would remain valid and thus BT recognizedthere
would be no evidence of conflict between NF C
17-102 and IEC EN 62-305 standards and
consequently there is no reason, technical or
otherwise, for the withdrawal of the respective
national standard.BT has requested that this
standard be modified in order to cancel all
reference to the IEC EN 62-305 series, allowing
the NF C 17-102 standard to exist, with the
proposal of possible future migration to
international level (lEC). Accordingly, it was
establishedthat European ESE standards (France,
Spain, Portugal, Slovaquia, etc.) will
notconflict with other European standards and
will remain valid.
- GIMELEC would draw your attention to the fact
that the terms of reference of NF C 17-102 and - other standards, addressing alternative terminals
(NF C 17-100, PR EN 61-024-1) were from the - outset, very different. It is a fact that NF C
17-102, whilst referring to ESE Technology also - comments on other standards for lightning
protection systems, particularly incorporating - faraday cage, franklin rod and catenary wire
systems. the 'camouflaging' of NF C 17-102 by IEC
EN - 62-305 and its proponents, that FRENCH STANDARD
NF C 17-102 is still in full force.
18Legal Witness and Explaination of ESEWe Support
This
19(No Transcript)
20(No Transcript)
21(No Transcript)
22(No Transcript)
23(No Transcript)
24Conlusion Letter
25Latest Solar Project ESE Type LA Documents
26IEC 62305 and NFC17-102
27Want to meet Expert in India for Lightning
Protection Instalation in your Facilities