Data Center Cooling is necessary to keep servers and other electronic devices in good working condition. If you have ever been working at your personal computer and heard the fan come on, then you have a reference point for this concept. Devices that use electricity produce a waste product of heat. When there are many electronic products in one place, such as a data center, then the amount of heat given off by such devices can add up quickly. High heat levels can be destructive for servers and other electronic devices, causing corrosion and potentially making information inaccessible. To keep your data safe, your center needs a cooling system. – PowerPoint PPT presentation

Number of Views:30
Slides: 3
Provided by: vertivco
Category: Other

less

Transcript and Presenter's Notes

Title: A Look at Data Center Cooling Technologies


1
A Look at Data Center Cooling Technologies
  • Data Center Cooling is necessary to keep servers
    and other electronic devices in good working
    condition. If you have ever been working at your
    personal computer and heard the fan come on,
    then you have a reference point for this concept.
    Devices that use electricity produce a waste
    product of heat. When there are many electronic
    products in one place, such as a data center,
    then the amount of heat given off by such
    devices can add up quickly. High heat levels can
    be destructive for servers and other electronic
    devices, causing corrosion and potentially making
    information inaccessible. To keep your data
    safe, your center needs a cooling system.
  • Data Center Cooling Systems
  • Maximize efficiency by preventing hot air
    contamination
  • Utilize cooling redundancy for stability and
    performance
  • Enable high performance compute power densities

Here Is The Essential Checklist For a Data Center
Cooling System Audit
  • CRAC Limit Check Make beyond any doubt that the
    current/arranged power stack for your server
    room is inside the endurable limit of the cooling
    system. Keep in mind that 1 Watt of IT control
    needs 1 Watt of cooling. Larger than average
    cooling frameworks may prompt unwanted vitality
    utilization. Discover the cooling framework limit
    in the model terminology on or inside each CRAC
    unit.
  • CRAC Unit Position Computer Room Air
    Conditioning (CRAC) Units are set opposite to
    the path on either a hot or frosty passageway in
    light of the

2
  • engineering of air circulation, and they are set
    toward the finish of hot walkways if raised
    floor is utilized for air conveyance.
  • Airflow Between Racks Gaps, unused rack spaces,
    unlocked link openings, and overabundance
    cabling hurt the cooling. Seal the holes and
    openings legitimately.
  • Test Cooling Circuits, Condenser Circuit, And
    Refrigerant Piping Ensure that chillers,
    condenser circuits, primary cooling loops,
    refrigerant piping, pumping systems, and
    evaporator coils are in proper condition. Check
    if all valves are working fine and that DX
    systems (if used) are fully charged.
  • Data Center Cooling infrastructure audits not
    only provide positive impact in terms of
    efficiency, but they also provide insight into
    the present state and help plan for alternative
    technologies and approaches.
  • It is important to understand that comfort
    cooling is not the primary purpose of data
    center cooling systems, even though the data
    center must be safe for the people who work in
    them.