Title: Five Steps To Maintain Cooling Towers
1Five Steps To Maintain Cooling Towers
www.kooldrop.com
2About Us
Kool Drop manufactures wooden induced draft cross
flow , frp round shape induced draft cooling
towers and frp rectangular shape induced draft
cooling towers.
Kool Drop cooling towers pvt ltd is a well known
iso 9001200 certified company having state of
the art manufacturing unit in delhi. kool drop
has supplied thousands of cooling towers all over
india. all major spare parts manufactured and
assembeled as per is standards under one roof.
Thousands of cooling towers have been supplied
and commissioned successfully by kool drop for
applications like hvac , dg sets, injection
moulding machines, induction furnaces, die
casting machines, dry cleaning machines, sugar
mills , breweries , paper mills have been
working satisfactorily for years.
3A Cooling Tower is specialized equipment used in
industries around the world. It is a heat
exchange device in which air and water are in
direct contact to reduce the temperature of the
water circulating in the tower.
Industrial customers need many cooling towers to
drive heat exchange applications. Without
installation, it is very difficult to release
unwanted heat from the circulation system. For
example, industrial customers are, for example,
very eager to look for a manufacturer of
high-quality cooling towers
Your cooling towers are essential to the
performance of any commercial or industrial air
conditioning system! Well-maintained cooling
towers and coolers maintain the condenser
temperature at lower temperatures than unmanned
systems. This translates into better energy
efficiency, lower utility bill costs and a more
comfortable installation.
4(No Transcript)
5Five steps to Maintain Industrial Cooling Towers
1. Remove Scale Deposits
Since your cooling tower is evaporating, you will
see a periodic build-up of scale deposits on your
bottom. Minerals in the water can create these
deposits, especially if you have problems with
water treatment. Limestone build-up can reduce
the efficiency and performance of your HVAC
system and lead to premature deterioration of
your unit. Descale your system several times a
year to increase energy conservation and keep
your monthly bills manageable.
62. Ensure a Good Airflow
Poor air circulation is a common cause of
non-cold air, poor fan performance and even
system failure. Airflow interruptions may occur
due to loose components, improper fan alignment,
and lack of maintenance on the transmission.
Damage to your fan blades can also reduce
airflow. Check your unit for debris in the tower
or your fill. Your cooling tower may have a
buildup of mud on the bottom of its pond that
blocks the airflow. Use a tower vacuum to remove
these contaminants. The addition of a biocide can
reduce the appearance of bacteria and algae in
your cooling tower.
73. Clean Your Tubes
Again, contaminants such as sludge, mud, algae
and scale can accumulate in the tubes of your
chiller and cause partial or total fouling.
Clogged tubes can cause malfunctions and failure
of the unit. The frequency with which you clean
your tubes will depend on the quality of your
water and its rate of accumulation. Each unit
will experience some kind of accumulation -
that's the nature of the system. By regularly
cleaning the tubes in your cooler, you will avoid
total obstructions and help remove debris. Your
industrial HVAC system contains kilometers of
tubes. You may need the help of a professional
to completely clean your tubes and improve your
efficiency.
84. Inspect the Water Pump
Most cooling systems use a water pump to deliver
warmer water to the chiller for cooling.
Efficiency during the pumping process can
significantly increase the performance of your
air conditioning, as well as reduce your monthly
energy bills. A well-maintained pump will not
have to work so much to circulate the water,
which will facilitate its operation and increase
its life. Inspect your pump and see if it is
turned on and off at the right time. Your pumps
should work as your cooler. Lubricate the
bearings of your pump and motor, as well as the
water seal. Also, periodically check your
alignment.
95. Treat the Water
The maintenance of cooling towers and chillers is
not limited to ensuring that the components of
your HVAC system are in good condition. You must
also pay attention to the quality of your water.
Water quality problems can lead to a significant
build-up of scum and scale, contributing to the
degradation of your system. Invest in effective
water treatment to protect your system and
achieve optimal performance. Contact Performance
Industrial for professional maintenance requests.
As a renowned supplier of cooling towers in
Delhi, Kool Drop processes a variety of tower and
cooling products. Popular tower products include
wood cooling towers, FRP round cooling towers,
FRP square cooling towers, RCC cooling towers,
energy efficient fans and other replacement
parts. If you are looking for accessories special
for customized tour, you can simply contact the
engineers. So if you want to install or repair
the towers, just call Kool Drop and the
professionals will take care of your needs.
10(No Transcript)
1191-9899443366 91-9891737437 91-9350250307
22, Hari Vihar , Opposite Dwarka Metro
Station Piller No. 818 Kakrola New Delhi-110078
www.kooldrop.com
kooldrop3k_at_rediffmail.com