The IEC/EN 61439 is the result of the work of technical committees and subcommittees composed of representatives of the full member national electrotechnical committees in Europe, each dealing with a particular subject in the entire range of Electrical products and assemblies. IEC standard 61439 covers low voltage switchgear and control gear assemblies. It is a replacement for the earlier IEC standard 60439 and is now the industry standard requirement for all low voltage switchgear and control gear panel assemblies. The new standard gives details on the requirements of products through testing and other verification methods especially at pre design stage. – PowerPoint PPT presentation

Number of Views:392

less

Transcript and Presenter's Notes

Title: IEC 61439 Standard in Electrical Busbar systems


1
IEC 61439 Standard inElectrical Busbar systems
www.messungelectricalengineering.com
2
  • Preface
  • In the Electrical manufacturing industry
    Standards which define clear rules are
    extremely necessary for safety, proper
    functioning to ensure quality at all levels.
    All the rules and recommendation under standards
    have been derived through extensive real world
    testing which assures correct or proper
    functioning of an electrical installation.z
  • Not adhering to standards can result into grave
    electrical hazard affecting the end user.
    Following standards ensures safe operation of the
    electrical installation for many years.
  • Introduction
  • The IEC/EN 61439 is the result of the work of
    technical committees and subcommittees composed
    of representatives of the full member national
    electrotechnical committees in Europe, each
    dealing with a particular subject in the entire
    range of Electrical products and assemblies.
  • IEC standard 61439 covers low voltage switchgear
    and control gear assemblies. It is a replacement
    for the earlier IEC standard 60439 and is now the
    industry standard requirement for all low voltage
    switchgear and control gear panel assemblies. The
    new standard gives details on the requirements of
    products through testing and other verification
    methods especially at pre design stage.

www.messungelectricalengineering.com
3
How does this new standard add value to the OEM,
Consultant, Designer and Panel Builder?
Why was the new standard created? In the earlier
IEC standard 60439, Design verification was
excluded, and therefore the respective roles of
equipment manufacturers and panel builders were
not clearly defined, so responsibility for
ensuring compliance was equally difficult to
pinpoint. .
  • The designer, be it from the consultant, OEM or
    the Panel builder identifies the needs and
    constraints for design, installation, operation
    and up-gradation of the complete system right at
    the design stage.
  • He chooses the correct switch gear, cables,
    connectors, busbar products and other components
    as per the specifications that he intends to use
    in his final assembly. Before he takes it up for
    manufacturing, at the design stage itself he
    needs to be sure that his choice of components
    are proper and that when the components are
    fitted in the control panel or Distribution panel
    that they follow the IEC 61439 standard.
  • To ensure this the designer carries out the
    design verification by various software tools
    provided by manufacturer which allows the
    electrical designer to be sure of his
    installation at an early stage.
  • 1) The verification of the design by actual
    testing himself or by third party labs by the
    calculation via prescribed tools supplied by the
    product manufacturer.
  • 2) Proper documentation of this design
    verification (e.g. test documentation,
    calculations) is then made by the prescribed
    tools provided by the manufacturer.

www.messungelectricalengineering.com
4
General information about IEC - 61439
  • The panel builder thus is not only responsible
    for the completed assembly but also responsible
    for
  • The rating of the switchgear assembly
    according to the customer requirements.
  • The compliance with the design verification
    of the original manufacturer.
  • The declaration of conformity to the
    customer (Declaration of Conformity)
  • The marking and documentation of the
    assembly
  • The performance of the design verification
    and documentation
  • In IEC 61439 three verification methods are
    recommended
  • First by test
  • Second by comparisons
  • Third with reference to design by assessment.
  • This covers Assemblies integrated for Generation,
    Transmission Distribution of Electrical Energy
    and assemblies designed for Electrical equipment
    all in the voltage range not exceeding 1000V AC
    or 1500V DC.

www.messungelectricalengineering.com
5
Wöhner Busbar System and IEC 61439 standards
  • Wöhner has been synonymous with top performance
    and innovation in technology for over 88 years.
    With over 100 registered patents, the Wöhner
    group is well established worldwide as a
    competent and reliable partner for energy
    distribution, control technology and renewable
    energies.
  • Wöhner has made it easier for electrical
    designers to adopt the new standard through
    verification methods by specially designed
    software tools on their website, which can be
    used for saving costs need for additional
    testing.
  • Short circuit strength Pre calculated tested
    by third party (avoids own testing requirements)
  • Temperature rise test Pre calculated tested by
    third party (avoids own testing requirements)
  • Current insulation Creep-age distance and
    isolation voltage pre-tested according to
    standards
  • Dielectric strength By specification in product
    data sheet ( Flexible Busbar )
  • If short circuit values are not taken in to
    consideration, during electrical fault there
    would be a serious fire hazard, harmful to
    everyone.
  • Wöhner provides the current carrying capacity of
    the busbar and short circuit withstand capability
    of the system by calculation method with special
    tools on the website.

Cross Board Classic
60 Classic
www.messungelectricalengineering.com
6
1. Tools for achieving IEC 61439
  • Wöhner provides following free online tools which
    can be used by designer/planners verify their own
    design and confer to all the standards under IEC
    61439
  • 1) Software for own design verification making
    the installation IEC complaint
  • 2) Configurator tool to design and achieve the
    required Short circuit withstanding capability
  • 3) Current carrying capacity of a Busbar
    busbar holder with respect to temperature of
    busbar enclosure
  • 4) Di-electric strength of the assembly of
    Busbar in the electrical enclosure

Software for own design verification making the
installation IEC complaint
Wöhner provides special software which can be
accessed under their website menu Tools where
designer can fill up the Verification by
comparison with a reference construction using
the checklist under this tool. And documentation
can be made for final submission to end user
conferring to IEC requirements.
www.messungelectricalengineering.com
7
2. Configurator tool to design and achieve the
required Short circuit withstanding capability
  • A snap shot of configurator tool to achieve
    desired level of short circuit rating
  • Wöhner configurator tool can be used to construct
    the power distribution and to achieve and
    maintain the desired short circuit withstanding
    capability of the system

www.messungelectricalengineering.com
8
3. To measure the Short circuit carrying capacity
of a Bus bar system 
  • We can check short circuit strength of a Busbar
    system by the design tools provided by Wöhner by
    the following simple steps
  • The short circuit strength mainly depends on few
    parameters like size of the busbar, number of
    supports and distance between the busbar
    supports.
  • Example
  • Using the design tools by Wöhner we select the
    busbar support in the 60Classic 3P range (01500
    Wöhner part number) busbar size of 20mmx10mm,
    Decide that we will be using two numbers of
    busbar supports and that the distance between
    number of supports will be 300 mm by giving these
    inputs in the design tools we receive the short
    circuit strength of 53 KA. (refer screen shot 1)

www.messungelectricalengineering.com
9
  • If we now change the distance between busbar
    support from 300 mm to 450 mm by maintaining all
    other parameters same we receive short circuit
    strength as 43 KA.

www.messungelectricalengineering.com
10
4. Current carrying capacity of Busbar systems by
design tools
  • We can check the Current carrying capacity of
    the Busbar systems by the design tools provided
    by Wöhner by the following simple steps.
  • The current carrying capacity of Busbar depends
    upon the Air temperature allowable inside the
    electrical cabinet and Busbar temperature that
    the end User has prescribed as Safe to use.
  • On the Wöhner website, we need to select the size
    of the busbar, temperature of air permissible in
    the electrical panel based upon the user
    specifications and allowable temperature of
    busbar as desired by the designer and allowed by
    the end user. By giving these inputs we can get
    the current carrying capacity of the Busbar.

For example if we select busbar to be of the size
20mm x10mm, with a length of 2.4m (Wöhner item
code -01624), and if we select air temperature of
35C and busbar temperature of 85C, we will get
the current carrying capacity 652A. (refer screen
shot 3)
www.messungelectricalengineering.com
11
  • Now if we keep the size of the busbar and busbar
    temperature as constant and change the allowable
    air temperature from 35C to 55C. We will then
    receive the calculation of the current carrying
    capacity of the Busbar to be 508 A.

An actual application photo of the control panels
using Wöhner products.
With Wöhner products, Usage verification can be
done right at the stage of design, Thus by using
the IEC 61439 standard and with the examples
mentioned above the Designer and the OEM
manufacturer and the Electrical panel builder can
design very good quality products. The End User
is then provided a system which he can trust and
be ensured about the Safety and reliability,
www.messungelectricalengineering.com
12
Other features of Wöhners unique Busbar
solutions
  • Innovative design by Wöhner allows mounting of
    electrical switch gear directly on busbars saving
    expensive real estate in the electrical panel.
    Wöhner products guaranty safety ease of
    assembly to our customers making the Assembly
    time reduce to 1/3rd of the conventional
    assembly time.
  • Copper Busbars are connected to cables LV
    switchgear (100A-1000A) without drilling the
    Busbars. Well-designed mounting adapters cable
    clamps provide a systematic compact power
    distribution panel along with all features like
    safety, ease of assembly, ease of maintenance,
    etc.

www.messungelectricalengineering.com
13
  • Conclusions
  • Electrical wiring design are the most critical
    part of any electrical installation. Wöhner
    Busbar system solution are uniquely designed as
    per IEC 61439 standard, and provides for free
    risk free compliance to standard with best
    safety, quality cost saving.
  • Farook Merchant - MD Messung Group (Mega
    Distributor for Wöhner Products in India.)
  • Working with world class standards brings
    International Quality to control panels
    manufactured by our customers. We are able to
    specify, test guarantee to our customer
    Critical specifications like Short circuit
    currents, temperature rise di-electric strength
    as per IEC 61439 standard. This new standard
    gives details on the requirements of Wöhner
    products through testing and other verification
    methods. It is intended to make up for some of
    IEC 60439s shortcomings.
  • Shrikanth Venkateshappa - International Key
    Account Manager, Wöhner.

www.messungelectricalengineering.com
14
THANK YOU