Thermal Mass Flow Meter PowerPoint PPT Presentation

presentation player overlay
About This Presentation
Transcript and Presenter's Notes

Title: Thermal Mass Flow Meter


1
Manas Microsystems Technology Excellence
Trust
Thermal Mass Flow Meter
www.manasmicro.com
2
About Thermal Mass Flow Meter
  • It is used to calculate the total mass flow rate
    of fluid, mainly gases, flowing through closed
    conduits.
  • It is a direct mass flow meter with no moving
    parts
  • Works effectively for large pipelines.
  • Doesnt require any pressure and temperature
    compensation

3
Theory of Operation
  • Thermal Mass Flow Meter contains two Platinum RTD
    temperature sensors
  • One sensor measures the fluid temperature as a
    reference.
  • The second sensor is heated and has a constant
    temperature differential relative to the first
    sensor.
  • When the flow of air/gas starts, heat is taken
    away from the warmer sensor.
  • The amount of heat taken away is having a direct
    relation with the mass velocity of the fluid.
    That is how it is a direct mass flow meter works.

4
Features of Thermal Mass Flow meter
  • Simple for installation.
  • There are no moving parts.
  • Pressure and Temperature compensation is not
    required.
  • Almost unobstructed straight flow path.
  • Very negligible pressure loss and pressure
    requirement, unlike differential pressure flow
    meters.
  • Straight pipe runs can be reduced by using flow
    conditioners or flow straighteners.
  • Very good repeat accuracy.

5
Applications of Thermal Mass Flow Meter
  • Compressed air/ Gas Consumption measurement
  • Gas measurement at very low-pressure flowing
    conditions
  • Fuel Gas like CNG consumption measurement and
    control
  • Automobile gas engine testing
  • Industrial oxygen flow measurement and control
  • Furnace and burner control
  • Biogas measurement in digester biogas digester
    systems

6
Technical Specification
Feature Description
Line Size DN 15 to DN 200
End Connection Flange/BSP(M) Threading/ Direct clamp mounting.
Accuracy 3 of Actual Flow Rate between 100 to 5 of Calibrated range
Display Blind/LCD 16/2.
Output 4-20 mA/RS 485, Pulse, Wireless Data Transfer.
Ingress Protection IP- 65
Operating Fluid Temp 0 100?
Operating Fluid Pressure Up to 10 bar
Power Supply 24Vdc/150mA (Without Wireless communication) 24Vdc/300mA (With Wireless Communication).
7
THANK YOU
EL 54, Electronic Zone, J-block, MIDC Bhosari,
Pune 411026. Maharashtra, India. Tel
8484039026 Ext. No. 106 Mob 91 77220 34924 /
74200 99054 mktg_at_manasmicro.com www.manasmicro.co
m
We are certified with ISO/IEC 170252017
ISO 90012015 ISO 140012015 OHSAS 450012018
Write a Comment