Title: How to Solve Common Generator Problems With Changeover Switchgears
1How to Solve Common Generator Problems With
Changeover Switchgears
2(No Transcript)
3- Standby engine generators, as the name suggests,
are vital for emergencies. They are kept as
backups to generate power during outages. Now,
swift activation of standby engine generators is
crucial when outages persist for a longer period
of time. Specific issues such as failure to
start, generator not connecting due to switchgear
malfunction, or operational failure
post-connection may sometimes delay the
activation of the generator. By using a branded
generator changeover switchgear, you can
eliminate these problems. - Common Generator Problems and the Ways to Address
Them - Problem 1 The generator engine failed to start
- Solution Confirm the engine and switchgear
controls are in automatic mode. Regularly check
battery health and charger power. Be cautious of
ATS not detecting power failure, hindering engine
start. Periodic ATS tests, briefly cutting normal
power, ensuring prompt engine response, and
verifying ATS functionality during utility
outages.
4- Problem 2 Engine running but failing to meet
critical load - Solution During routine maintenance, technicians
must validate the correct switchgear neutral
switch timing setpoint. Regular checks should
ensure the engine main breaker is closed. Adjust
the breaker setting to avoid unnecessary trips
under load. Conduct frequent transfer tests
initiated manually at the ATS without opening
circuit breakers to prevent failure modes. The
common failure modes are - The ATS does not acknowledge acceptable
generator power - ATS jamming or failing to transfer
- And, contacts fail under load post-transfer
- This proactive approach ensures the reliability
of the generator switchgear and minimises
potential operational failures.
5- Problem 3 The engine carries the load smoothly
but fails before the return of utility power - Solution Prevent fuel-related issues by
routinely inspecting pumps and filters for
contamination. Run the generator for extended
periods to confirm prolonged performance and
avert these potential failure modes. - Engine overheating
- Component failures
- Incompatibility issues with load, such as
voltage regulator or speed governor issues - Problem 4 The engine still runs after stable
utility power returns - Solution Verify switchgear setpoints for
potential manual transfer requirements. Ensure
correct adjustment of the ATS-in-phase monitor
and appropriate engine frequency for seamless
in-phase monitoring and closed-transition
transfer.
6Avoid generator issues with the best
switchgears Selecting the right generator
changeover switchgear is critical for unhindered
power transitions during power cuts and supply
outages. The choice influences the reliability of
backup power systems by ensuring timely and
automatic shifts between utility and generator
power. Well-designed switchgear minimises the
risk of failure modes, such as failure to
recognise utility power return or jams during
transfer. Find the best switch gears with Blades
Power Generation today!