Standby engine generators, as the name suggests, are vital for emergencies. They are kept as backups to generate power during outages. Now, swift activation of standby engine generators is crucial when outages persist for a longer period of time. Specific issues such as failure to start, generator not connecting due to switchgear malfunction, or operational failure post-connection may sometimes delay the activation of the generator. – PowerPoint PPT presentation

Number of Views:1
Slides: 8
Provided by: bladespower
Category:
Tags:

less

Transcript and Presenter's Notes

Title: How to Solve Common Generator Problems With Changeover Switchgears


1
How to Solve Common Generator Problems With
Changeover Switchgears
2
(No Transcript)
3
  • Standby engine generators, as the name suggests,
    are vital for emergencies. They are kept as
    backups to generate power during outages. Now,
    swift activation of standby engine generators is
    crucial when outages persist for a longer period
    of time. Specific issues such as failure to
    start, generator not connecting due to switchgear
    malfunction, or operational failure
    post-connection may sometimes delay the
    activation of the generator. By using a branded
    generator changeover switchgear, you can
    eliminate these problems.
  • Common Generator Problems and the Ways to Address
    Them
  • Problem 1 The generator engine failed to start
  • Solution Confirm the engine and switchgear
    controls are in automatic mode. Regularly check
    battery health and charger power. Be cautious of
    ATS not detecting power failure, hindering engine
    start. Periodic ATS tests, briefly cutting normal
    power, ensuring prompt engine response, and
    verifying ATS functionality during utility
    outages.

4
  • Problem 2 Engine running but failing to meet
    critical load
  • Solution During routine maintenance, technicians
    must validate the correct switchgear neutral
    switch timing setpoint. Regular checks should
    ensure the engine main breaker is closed. Adjust
    the breaker setting to avoid unnecessary trips
    under load. Conduct frequent transfer tests
    initiated manually at the ATS without opening
    circuit breakers to prevent failure modes. The
    common failure modes are
  • The ATS does not acknowledge acceptable
    generator power
  • ATS jamming or failing to transfer
  • And, contacts fail under load post-transfer
  • This proactive approach ensures the reliability
    of the generator switchgear and minimises
    potential operational failures.

5
  • Problem 3 The engine carries the load smoothly
    but fails before the return of utility power
  • Solution Prevent fuel-related issues by
    routinely inspecting pumps and filters for
    contamination. Run the generator for extended
    periods to confirm prolonged performance and
    avert these potential failure modes.
  • Engine overheating
  • Component failures
  • Incompatibility issues with load, such as
    voltage regulator or speed governor issues
  • Problem 4 The engine still runs after stable
    utility power returns
  • Solution Verify switchgear setpoints for
    potential manual transfer requirements. Ensure
    correct adjustment of the ATS-in-phase monitor
    and appropriate engine frequency for seamless
    in-phase monitoring and closed-transition
    transfer.

6
Avoid generator issues with the best
switchgears Selecting the right generator
changeover switchgear is critical for unhindered
power transitions during power cuts and supply
outages. The choice influences the reliability of
backup power systems by ensuring timely and
automatic shifts between utility and generator
power. Well-designed switchgear minimises the
risk of failure modes, such as failure to
recognise utility power return or jams during
transfer. Find the best switch gears with Blades
Power Generation today!
7