Controlled Operations Limited (COL, Inc.)
  • Owner Dr. V. G. J. Rodgers

2
Budget Cut Announcement
Dear Engineers. Our Company will be merging
with the Japanese Company, Imaginary Control
Enterprises (ICE) to form a new global control
dynasty. We will become ICE-COLD Inc.
3
Budget Cut Announcement
We are now faced with a need to remove all dead
weight as we establish the worlds number one
control company. ICE executives will flying in
next week to review your work Thursday morning.
Your next presentation on PID control aspects of
your particular projects will be used to
determine who will remain in our dynamic control
engineering design dynasty. In other words..
4
Budget Cut Announcement
Only the Baddest of the Bad will remain.
5
Weight of Effort Adjustment
Due to limited experimental equipment and
streamlining of the evaluation process, the
following is the revised program weighting
parameters.
6
Weight of Effort Adjustment
Homework 200Challenge 1 (Accountability
Assessment Report) 200Challenge 1 (Oral
Accountability Assessment) 150First
Mid-Term 250Second Mid-Term 250Challenge 2
Process Dynamics and Control (Accountability
Assessment Report) 500Challenge 2 Process
Dynamics and Control (Oral Confidence and
Accountability Assessment) 450TOTAL 2000
7
Weight of Effort Adjustment
Given the great weight on the final work all
written material will now be due on December 16,
700 a.m.
8
December 16, 2004 Schedule
All activities will be in room 3321 and everyone
must be there at 700 a.m.Each group will be
given only 15 minutes total.
9
December 16, 2004 Schedule
700 a.m. Stephanie and Julia715 Valerie and
Aiman730 Brett and Yudai745 Jeff and
Ryan800 Benjamin and Josh815 Hung, Kim and
Rebecca830 Thomas and Luana845 Tom and
Erin900 Tommy and Afton
10
Presentation Preparation
Dr. V. G. J. Rodgers has asked that we prepare
you for the level of intensity of ICEs visit.
The remaining presentation, based on the work of
Seborg et al. will be used to guide you.
11
Got Control?
  • It is your control analysis that will carry the
    greatest weight in your evaluation.
  • Think globally! In the end how is your system
    handling disturbance and setpoint changes.
  • Stability analysis compare methods but know the
    limitations. With approximation methods, do not
    expect exact answers.
  • Tuning methods. These are only getting you in the
    ballpark. Are fine tuned results better? By how
    much. Remember, decimal place accuracy is not
    that important.

12
Overview System Description
  • We want our control system to handle disturbances
    and setpoint changes nicely.

disturbance
manipulated variable
Develop the open loop model for the system
process variable
13
Getting There 1) Open Loop
  • We want our control system to handle disturbances
    and setpoint changes nicely.

14
Getting There 2) Closed- Loop
Now its all about control Gc
15
Closed Loop Behavior Examples
  • Change the Setpoint (Servo Problem)

Setpoint changed from 0 to 1 here. Offset in this
case because P-only control.
16
Closed Loop Behavior Examples
  • Disturbances Occur (Regulator Problem)

Setpoint remains at 0.
17
Overview 3) Its All About Gc
  • We will be using PID control.
  • Ideal PID

P PI PD PID
18
Overview 3) Its All About Gc
  • Oh great one. But what values of Kc, tI, tD shall
    we use for our controller?
  • Stability Analysis. Look at P-only control
  • Find your range in which you are limited
  • Use basic tuning techniques to get approximate
    controller parameters
  • Model closed-loop controller system
  • Fine tune and analyze

19
Stability 4) Overview
  • Closed-Loop
  • Find your range in which you are limited
  • Use basic tuning techniques to get approximate
    controller parameters
  • Model closed-loop controller system
  • Fine tune and analyze

20
Stability 5) Closed-Loop Methods
Closed-Loop Methods Use the Characteristic
Equation
Set Equal to zero is the characteristic equation
21
Stability 5) Closed-Loop Methods
Figure 11.25 Stability regions in the complex
plane for roots of the charact-eristic equation.
22
Stability 5) Closed-Loop Methods
  • Closed-Loop Methods
  • Direct Substitution
  • Routh-Horowitz Stability Criterion
  • Root Locus
  • Need to Approximate Dead time with Pade

23
Stability 5) Closed-Loop Methods
Root Locus
24
Stability 6) Open-Loop Methods
25
Stability 6) Open-Loop Methods
  • Open-Loop Methods Frequency Response
  • Bode Diagram
  • Nyquist Diagram
  • No Need to Approximate Dead time
  • Model behavior of

input
output
26
Stability 6) Open-Loop Methods
Get these from
Step 1. Set sjw in G(s) to obtain
. Step 2. Rationalize G(jw) We want to express
it in the form. G(jw)R jI where R and
I are functions of w.
27
Stability 6) Open-Loop Methods
Unstable Kc
Critical Kc
Stable Kc
28
Stability 6) Open-Loop Methods
Unstable if encircles -1
29
Tuning 7) Reaction Curve Methods
30
Tuning 7) Reaction Curve Methods
q
31
Tuning 7) Reaction Curve Methods
Use model to get values of Kc, tI, tD from
appropriate tables in Chapter 12.
32
Tuning 7) Reaction Curve Methods
  • Introduce into PID controller

P PI PD PID
33
Tuning 7) Reaction Curve Methods
Use These Gcs in the Closed-Loop System
Take Inverse Laplace for Step or Impulse Changes
in setpoint or disturbances
34
Tuning 7) Reaction Curve Methods
  • Change the Setpoint (Servo Problem)

Setpoint changed from 0 to 1 here. Offset in this
case because P-only control.
35
Tuning 7) Reaction Curve Methods
  • Disturbances Occur (Regulator Problem)

Setpoint remains at 0.
36
Tuning 7) Reaction Curve Methods
  • Fine Tune to Your Liking!

Setpoint remains at 0.
37
Tuning 8) Ziegler Nichols Method
  • Continuous Cycling Method

38
Tuning 8) Ziegler Nichols Method
39
Tuning 8) Ziegler Nichols Method
  • But Can Get Kcu and Pu from Nyquist (Bode, Root
    Locus, Routh Stability)!

40
Tuning 8) Ziegler Nichols Method
  • Introduce into PID controller

P PI PD PID
41
Tuning 8) Ziegler Nichols Method
Use These Gcs in the Closed-Loop System
Take Inverse Laplace for Step or Impulse Changes
in setpoint or disturbances
42
Tuning 8) Ziegler Nichols Method
  • Change the Setpoint (Servo Problem)

Setpoint changed from 0 to 1 here. Offset in this
case because P-only control.
43
Tuning 8) Ziegler Nichols Method
  • Disturbances Occur (Regulator Problem)

Setpoint remains at 0.
44
Tuning 8) Ziegler Nichols Method
  • Fine Tune to Your Liking!

Setpoint remains at 0.
45
Final Thoughts
  • ICE COLD is expecting only the best from you.
  • Good luck to all of you!