Title: First, very preliminary Results from the Solid-State Electron EDM Experiment


1
First, very preliminary Results from the
Solid-State Electron EDM Experiment
  • nEDM collaboration meeting
  • June 21, 2005

2
(No Transcript)
3
Sensitivity estimate
4
Enhancement Factor of eEDM
  • Buhmann, Dzuba, Sushkov, Phys. Rev. A 66, 042109
    (2002).
  • Dzuba, Shushkov, Johnson, Safronava, Phys. Rev.
    A 66, 032105 (2002).
  • Kuenzi, Sushkov, Dzuba, Cadogan, Phys. Rev. A
    66, 032111 (2002).
  • Mukhamedjanov, Dzuba, Sushkov, Phys. Rev. A 68,
    042103 (2003).

5
HV Electrodes Magnetic Flux pick-up coils
(planar gradiometer)

0
_
2.5
5
  • Common mode rejection of external
  • uniform B field and fluctuations.
  • CMRR238, (0.4 area mismath.)
  • Enhancement of sample flux pick-up.

6
Waveforms
HV monitor
Current In the ground plate
SQUID signal
7
Data Processing
1
-3
3
-1
Get rid of the long time drifting function up to
the second order terms.
8
Flux sensitivity estimate for the prototype
experiment
9
EDM signal
4K, 2.8kVpp, 1.13Hz, 50 minutes
SQUID signal (-2.68-5.5)e-7 V
-6.6E-08 - 2.8085E-07 V (drift corrected)
Leakage Current (-4.6e-5 - 1e-6 ) x10 uA
10
SQUID signal
Standard deviation
SQUID transfer function
B.V. Vasilev and E.V. Kolycheva, Sov. Phys.
JETP, 47 2 243 (1978) de(8.1 ?11.6)?10-23 e-cm
4K, 2.8kVpp, 1.13Hz, 50 minutes
11
eEDM sensitivity that can be achieved with the
prototype
  • With the same configuration, 4 days of data
    averaging will give an eEDM limit of 1e-24 e-cm.
  • Increase HV from 2.8kVpp to 7kVpp will push the
    eEDM limit to 4e-25 e-cm in 4 days data at 4K.
  • Using a 2K bath, eEDM limit 2e-25 e-cm.
  • At 400mK, eEDM limit 4e-26 e-cm.
  • At 40mK, eEDM limit4e-27 e-cm.

12
Finite Leakage Current ???
13
  • Liquid Helium level runs low during the run.

14
Zero-crossing Waveform
15
EDM measurements vs time
16
Standard deviation
17
Spin Noise
18
EDM signal
19
Leakage Current