Title: A CANADIAN COMPANY
1A CANADIAN COMPANY
Providing Complete Power Solutions For Mission
Critical Industrial Applications
2Agenda
- Introduction
- Industry Problems Solutions
- UPS Products
- Standards Technologies
- UPS Peripheral Products
- Power Quality Products
- Standards Technologies
3Power Problems/Solutions
All Always On UPS Systems Incorporate TVSS and
LPS Filters
4Technologies
- UPS Systems
- Back-up/Standby (Antiquated Technology No
Longer Manufactured) - Line Interactive UPS Systems
- Dual Conversion On-line UPS Systems
- Frequency Converters (Electronic)
- Convert 50/60/400Hz In to 50/60/400Hz Out
- UPS Peripherals
- Smart Electrical Distribution Panel
- Wrap Around Bypass
- Power Quality Products
- Low Pass Series Filters
- Transient Voltage Surge Suppressors (TVSS)
- Isolating Line Filter
5UPS Terms
- UPS Terms
- THD
- Crest Factor
- Power Factor Correction (PFC)
- Buck/Boost
- Modified Sine Wave/True Sine Wave
- Transfer Time
- Battery Terms
- Float
- Equalization
- Constant Current Charging
- Constant Voltage Charging
- VRLA
6UPS Technologies
- Line Interactive
- Utility Supplies Power to Load Until Utility
Failure - 2-4 ms Transfer Time
- Note 16.7ms/Cycle at 60Hz
- Load Not Isolated From the Utility
- Utility Should Be Conditioned Surge Protection
(Filtered Surge Protected) - Utility Should Be Voltage Regulated
- Buck Boost
- Modified Sine Wave (PWM) or True Sine Wave
- Generally Smaller kVA Output (Less Than 3 kVA)
7UPS Technologies
- Line Interactive Modified Sine Wave
- Modified Sine Wave Output When On Battery Supply
- Output RMS Voltage Regulated By Pulse Width
- Inverter Only Functions When Utility Has Failed
- Should Provide Voltage Regulated, Filtered AC
Utility to Loads Until Utility Failure Occurs.
8UPS Technologies
- Line Interactive True Sine Wave Output
- True Sine Wave Output At All Times
- Provides Voltage Regulated, Filtered AC Supply to
Loads Until Power Failure Occurs - Inverter Operates When AC Supply has Failed
- CPU Always Synchronizing Inverter Phase with AC
Supply Phase - Bi-Directional Inverter Also Charges the
Batteries. - Inverter will maintain phase with AC supply
9UPS Technologies
- Line Interactive Block Diagram
10UPS Technologies
- Dual Conversion Online UPS
- Zero Transfer Time
- Always
- Isolates the Load From the Input AC
- Rectifies the Input AC
- Power Factor Corrects to Unity pf1
- Generates A True Sine Wave Output With the
Inverter - Supplies Regulated Isolated Voltage To the Load
- Synchronizes to the Input Phase When Online
11Dual Conversion On-Line UPS System
12Dual Conversion Key Components
13Dual Conversion Key Components
- Inverter Output Filter
- Insulated Gate Bipolar Transistors
- Unipolar PWM Waveform Generation
- Filtering For True Sine Wave Output
14Dual Conversion Waveforms
- PWM Generation Resulting IGBT Output
- Unipolar PWM Wave Generator
- Modulates a Reference Sinewave With a Triangle
Carrier Wave. - Triangle Wave Frequency around 22kHz (Above
Audible Range). - Less Harmonic Power to Filter, Greater
Efficiency, Smaller Size
15Dual Conversion Output Waveforms
- Unfiltered Inverter Output Filtered Output
- Output Filtering
- Eliminates the chop/step on the output waveform
from the Inverter Circuit - Ensures the current and voltage waveform stay
in-phase for unbalanced loads.
16(No Transcript)
17Dual Conversion On-Line UPS
18Dual Conversion On-Line UPS
19Dual Conversion On-Line UPS
20Dual Conversion On-Line UPS
21Dual Conversion On-Line UPS
22Dual Conversion Online
- Key Components
- User Interface
- LCD Display with Push Button.
- Real Time Status
- Event Logs
- User Settings
- Communications Port
- Serial Communication / Open Collector Port.
- Monitor Log UPS Status.
- Provide Warning to Customers,
- Peripheral Devices for Orderly Shutdown etc.,
- Warnings of Anomalies That May Occur (Power
Outage, Battery Condition, etc.).
23Dual Conversion Online
- Key Components
- CPU Control
- Controls the Synchronization Circuit
- Matches the Input and Output Frequencies (PLL)
- Allows Static Manual Bypass to Function
Correctly - Monitors and Regulates All Systems Within the UPS
- Ensures Constant, Clean and Regulated Voltage
- Monitors Overloading
- Monitors Vital Statistics and Alarm Points
- Monitors Utility Condition
24Dual Conversion Online
- Prerequisites
- Supplied AC Utility
- Always Converted to DC and Then to AC Via
Inverter - Critical Loads Are Always Isolated From Dirty
AC Supply - Cleans Up Dirty Auxiliary Generator Power
- Transfer of Power to Battery Back-Up is Seamless
(0 Transfer Time) - Input Current is Power Factor Corrected to Unity
pf1 - Isolation Transformers Standard for Larger
Systems - True Galvanic Isolation for Common Mode Noise
Removal - Always Provides Clean, Regulated, Noise Free Power
25Dual Conversion Online
- Peripheral Equipment
- External Wrap-Around Bypass
- Allows for the Removal of UPS Without Disturbing
the Critical Load - Options
- Isolation Transformer
- Kirk-key Interlock
- UPS Powered Smart Distribution Panel
- Isolates Faulted Load Circuit
- Protects Against Additional Load Failures Due to
Initial Faulted Circuit
26 Always On UPS Systems Single Line Drawing of
UPS System and External Bypass System (Generic)
27Dual Conversion Online
- UPS Site Considerations
- Load Characteristics
- Voltage, Current, Frequency, Load Type i.e.
motors, PLC, PC - Power Source
- Voltage, Utility or Generator?
- Extended Back-up Time
- How Much?
- Communication/Monitoring Requirements
- Location
- Environment
- Space Limitations
28Dual Conversion Online
- Services To Be Provided
- Engineered Solutions (Feature, Function, Form,
Fit) - Site Planning Services
- Power Evaluation
- Installation Commissioning
- Operator Training
- Preventative Maintenance
- Extended Warranty
29Dual Conversion Online
- Recommended Options
- Extended Runtime Cabinets
- Remote Monitoring Panel
- Remote Emergency Stop
- Communication Interfaces (SNMP, AS-400, Relay
I/O) - Batteries (5/10/20 Year Warranties)
30Frequency Converters
- Prerequisites
- Convert 50/60/400Hz Input to
- 50/60/400Hz Output
- User Specified
- True Sine Wave Output
- Full Galvanic Isolation
- Solid-State Electronic Conversion
- Options
- 12 Pulse Rectifier
- Parallel Redundancy
31Power Quality Products
- Industry Standards
- Power Quality Technologies
- Application of Power Quality Technologies
- Single Phase
- Three Phase
- Control Communication
32Industry Standards
- IEEE (ANSI) C62.41
- Defines Test Practices on Surge Protection
Devices - 3 Categories
- Category A (1,23)
- Long Branch Circuits Outlets
- Category B (1,23)
- Major Sub Distributions Panels Short Branch
Circuits - Category C (1,23)
- Outside Service Entrances
33Industry Standards
Combination Wave
Ring Wave
34Power Quality Products
- Technologies
- TVSS
- Line Filtering
- Line Isolation
- Communication Filtering and TVSS Protection
- Over Load Protection
35TVSS Filters
- Features
- Protection of Electrical Service Entrance and
Sub-Panels - Against
- Massive Surge Impulses, Indirect Lightning
Strikes, - Common Normal Mode Noise, Spikes, Transients,
- Low Frequency Harmonics
- Should Be Available in 1Ø 3Ø Versions
- Wall Mount/Flush Mount
36Series Design Isolating Line Filter
- Features
- Total Isolation
- Re-establish 0 Volts Ground References
- Low Pass Series Filtering
- Eliminate 100 of Common Mode Noise
- User Replaceable Modules
37Series Design Low Pass Filter
- Should Offer AC Protection
- Dry Contact Status
- DC Data Line Protection.
- Industrial LANs
- Twisted Pair, 3 wire up to 100 Mb/sec
- ModBus, DH
- RS-485 and RS-422
- DeviceNet
38Always On ManufacturedSystems
Side Mount
NEMA 12
Cabinet Types
Rack-mount
3 Phase 208-600V 10 - 250kVA
39Competitive Advantage
Always On Provides Totally Filtered
Protection
40High End UPS Systems Address
1 Harmonic Distortion
41High End UPS Systems Address
1 Harmonic Distortion 2 Switching Transients
42High End UPS Systems Address
1 Harmonic Distortion 2 Switching Transients
3 Line Noise
43High End UPS Systems Address
1 Harmonic Distortion 2 Switching Transients
3 Line Noise 4 Frequency Variations
44High End UPS Systems Address
1 Harmonic Distortion 5 Power Surges 2
Switching Transients 3 Line Noise 4
Frequency Variations
45High End UPS Systems Address
1 Harmonic Distortion 5 Power Surges 2
Switching Transients 6 Power Sags 3 Line
Noise 4 Frequency Variations
46High End UPS Systems Address
1 Harmonic Distortion 5 Power Surges 2
Switching Transients 6 Power Sags 3 Line
Noise 7 High Voltage Spikes 4 Frequency
Variations
47High End UPS Systems Address
1 Harmonic Distortion 5 Power Surges 2
Switching Transient 6 Power Sags 3 Line Noise 7
High Voltage Spikes 4 Frequency Variations 8
Brownouts
48High End UPS Systems Address
1 Harmonic Distortion 5 Power Surges 9 Power
Failures 2 Switching Transients 6 Power Sags 3
Line Noise 7 High Voltage Spikes 4 Frequency
Variations 8 Brownouts
49Always On Manufactured
- Dual Conversion (Single Phase)
- N-Series
- 700VA 3kVA
- Single Ø In, Single Ø Out
- TN-11
- 5kVA 20kVA
- Single Ø In, Single Ø Out
- TN-31
- 10kVA 20kVA
- Three Ø In, Single Ø Out
50Dual Conversion Online
- Features of the N TN Series
- Regulated True Sine Wave
- Low THD
- Extended Battery Run-Time Available
- Power Factor Correction
- Cold Start From Battery
- Auto Restart After Extended Blackout
- Auto Frequency Detection
- When On Utility
- Automatic Voltage Regulation
- Surge Suppression TVSS
51Dual Conversion Online
- N TN Features Continued
- Rack mount and Other Configurations Available
- Relay I/O Module For DCS Monitoring
- Simple Management Network Protocol (SNMP) Slot
- RS-232 Communication Open Collector Alarm
Points - Audible Alarms
- Remote Emergency Stop Feature
52Three Phase UPS Systems Dual Conversion Online
NX Series
- NX-Series Additional Features
- 10 kVA to 250 kVA
- 120/208//277/480//347/600V
- 6 or 12 Pulse Rectifier
- Isolation Transformer
- Maintenance Bypass
- High Efficiency
- Alarm Contacts, RS-232, RS-485, SNMP
- N1 Redundancy (IPRO)
- Up To 8 Units In Parallel, 2 MVA Combined
- Extended Runtimes Available Customizable
53GENIE UPS Powered Smart Panel
- Designed to Identify a Overload Condition
- Clears Circuit In Less Than 1 Cycle
- Prevents Total Shutdown Of UPS
- Prevents Damaging And/or Dangerous Short Circuit
to UPS. - Eliminates the Time Window of Thermal Breakers
(18 to 22 Cycles) - Intelligent Design
- Distinguishing Between
- Normal Inrush Current
- Short Circuit or Overload Condition.
- Genie Communications Available for
- Controller Monitoring and Alarm
- Simple Plug-in Breaker Design
- Easy Upgrade or Replacement.
54DC UPS Systems
- Convert AC Utility to DC
- Provides DC Backup by Drawing Off Batteries
During Utility Failure. - Filters Conditions DC Supply
- Removes
- Sags, Surges, Transients, Noise
- Blackouts, Over-Voltages
55Din Rail Mounted UPS
- Convenient Din Rail Mounted Enclosure.
- Optional Extended Back-Up Time.
- DC Switching Module
- 120VAC and 24VDC Output
- Offered in a Variety of Current Ratings
56ELECTRICAL SERVICE ENTRANCE TVSS FILTER - 1Ø
3Ø models
- 1Ø or 3Ø
- Delta or Wye, Up to 600 Volts
- Commercial and Industrial Applications.
- Removable Phase/Fuses,
- Self Diagnostics - LED Indicators Per Phase.
- Optional Surge Counter, Dry Contact Form C and
Fault Test Button.
57PLC 22 and 20 Protector
- The PLC 20 offers AC protection only.
- The PLC 22 offers AC DC protection as well as
Data Line Filtering. - Dry Contact (Forms A, B and C) are available
- DC Data Line Protection.
- Industrial LANs
- Twisted Pair, 3 wire up to 100 Mb/sec
- ModBus, DH
- RS-485 and RS-422
- DeviceNet
Din Rail
58TTF/ILF Isolating Line Filter
- Total Isolation
- Low Pass Series Filtering
- Re-establish 0 Volts Ground References
- Eliminate 100 of Common Mode Noise
- User Replaceable Modules
59Always On Manufactured
- Additional Product Technologies
- DC Power Source Controllers
- Rectifiers/Chargers 12, 24 and 48 Volt 20,
40, 60A - Inverters Numerous sizes
- Power Supplies DC/DC
Proprietary Patents Pending
60Always On Offers
- Engineered Designed Solutions
- Cutting Edge Technology
- Localized Service
- Individualized Support