Geometric Determinants of XANES Structure - PowerPoint PPT Presentation

1 / 18
About This Presentation
Title:

Geometric Determinants of XANES Structure

Description:

... of XANES Structure. Mehmet Karabiyik, Kyle Bolduc, and James E. Penner-Hahn ... b) X-Ray Absorption: Principles, applications, techniques of EXAFS, SEXAFS ... – PowerPoint PPT presentation

Number of Views:79
Avg rating:3.0/5.0
Slides: 19
Provided by: mjs77
Category:

less

Transcript and Presenter's Notes

Title: Geometric Determinants of XANES Structure


1
Geometric Determinants of XANES Structure
  • Mehmet Karabiyik, Kyle Bolduc, and James E.
    Penner-Hahn
  • Department of Chemistry, University of Michigan,
    Ann Arbor, MI, 48109,USA

2
X-ray Absorption Spectroscopy (XAS)
XANES - X-ray Absorption Near Edge Structure
EXAFS - Extended X-ray Absorption Fine Structure
a) Newville, M., http//cars9.uchicago.edu/xafs/xa
s_fun/xas_fundamentals.pdf b) X-Ray Absorption
Principles, applications, techniques of EXAFS,
SEXAFS and XANES, (eds. Koningsberger, D. C.,
Prins, R.), John Wiley Sons New York, 1988.
3
Environment of the Active Site Zinc
MetH
Active site zinc has three cysteine residues and
a water molecule
MetE
Active site zinc has two cysteine residues, a
histidine residue and a low-Z ligand
Peariso, K. et al. J. Am. Chem. Soc. (1998), 120,
8410-8416. Zhou, Z. S., Peariso, K. Penner-Hahn,
J. E., Matthews, R. G. Biochemistry, 1999, 38,
15915.
4
Zinc is required for catalytic turnover in MetH
Matthews, R. G. Acc. Chem. Res. (2001), 34,
681-689
5
As With MetH, Zinc is Required for Catalytic
Activity in MetE
González, J. et al. Biochemistry, 1996, 35,
12228-12234.
6
XANES changes depend on addition of substrate,
but not on identity of substrate
7
XANES differences are identical for Hcy and
SeHcy, and similar for ZnS3(N/O) and ZnS2(N/O)2
sites
8
Origin of XANES differences?
Not oxidation state. Not ligation. May be
geometry?
XANES differences for different ZnS2(N/O)2
enzymes are distinct.
9
Model Compounds
Ni(Dts)22-
Zn(Dts)22-
Dts1,2-Cyclobutenedione-3,4-dithiolate
Holah, D.G. Hollander, F.J. Coucouvanis, D.
Inorg. Chem. 1975,14,2675-2665 Wenzel, B.
Durutkowski, U. Strauch, P. Z.Anorg.Allg.Chem.20
01, 627, 923
10
XANES changes appear to correlate with changes in
geometry
XANES changes appear to correlate with changes in
geometry
11
K vs. PPh4
Counter ion is not the main factor in XANES
12
Bulk and Doped sample Spectra Comparison
Geometry changes affect XANES dramatically
13
Zn(Dts)2(PPh4)2 Data vs. Feff8
BTABenzyltriethylammonium
14
K2Ni(Dts)2 and K2Co(Dts)2 Calculations
15
Conclusions
  • XANES is highly geometry dependent.
  • More elaborate calculations need to be done.

16
Acknowledgements
  • Prof. Dr. James E. Penner-Hahn
  • Penner-Hahn Group Members
  • NIH

17
Systematic Change of Geometry
18
Systematic Change of Afolp Card Value
Write a Comment
User Comments (0)
About PowerShow.com