Title: Automated Vacuum BakeOut Station


1
Automated Vacuum Bake-Out Station
2
Team Members
  • Taiyoh Afrik
  • Chad Conner
  • Lee Groeneweg
  • Michael Jourden
  • Colleen Koperski

3
Presentation Overview
  • Objectives
  • Mechanical Design
  • Process Control and Data Acquisition
  • System Features
  • Budget
  • Schedule

4
Objectives
  • Automate the existing manual bake-out process.
  • Design a data acquisition system to gather
    pressure and temperature data from the bake-out
    process.
  • Design adjustable fixturing to hold varying sizes
    of catalytic converters.

5
Mechanical Design
  • Fixture
  • Aluminum base plate
  • Retractable fixturing - shells and heat blower
  • Manifold for compressed air
  • Cooling Ring
  • Air Amplifier

6
3-D Model of Fixture (heating)
7
3-D Model of Fixture (cooling)
8
Process Control and Data Acquisition
  • LabView, used for the process control and data
    acquisition systems.
  • National Instruments (NI4351) DAQ card, for
    thermocouple inputs.
  • 14 thermocouple inputs with signal conditioning
    built into the board.
  • 8 digital TTL I/O

9
Process Control and Data Acquisition (continued)
  • National Instruments (PCI-6024E) DAQ card, used
    for all other inputs and outputs.
  • 16 analog inputs
  • 2 analog outputs
  • 8 digital TTL I/O

10
Control System Features
  • System will have an emergency stop button.
  • Vacuum pump is shut off
  • Heat blower and radiant heaters are turned off
  • Vacuum shut off valve is activated
  • Variable set points for process temperature and
    pressure through LabView.
  • Electrical enclosure will have quick connects for
    thermocouples.

11
Pressure Gauges
  • 2 pressure gauges required for measurements over
    large range of vacuum pressures.
  • Range 1 Atmosphere to 10-3 torr.
  • PS216 from MKS Instruments
  • Range 2 10-3 - 10-5 torr.
  • PS205 from MKS Instruments

12
Heat Blower
  • Leister Hot Wind S
  • Fixed 12 CFM
  • Heat up to 800 degrees Celsius
  • Power 2850 Watts
  • Source 220VAC
  • With the optional digital controller, the
    temperature of the Hot Wind S can be remotely
    controlled by an analog signal.

13
Budget
14
(No Transcript)
15
Schedule
  • Parts will be ordered during the week of April
    21, 2000.
  • Building of the fixturing will begin May 8, 2000
    and be completed by June 9, 2000.
  • The control system will be built and wired
    beginning on May 8, 2000, and will be completed
    by June 23, 2000.

16
Schedule (continued)
  • Final system debugging is scheduled to be
    completed July 10, 2000.
  • Test parts will be run starting July 11, 2000,
    and continue until the system is functioning
    correctly.
  • VBO station presented for approval by August 4,
    2000.
  • Final product delivered upon approval.

17
Questions and Answers
Automated Vacuum Bake-Out Station