PortaCount Plus - PowerPoint PPT Presentation

1 / 31
About This Presentation
Title:

PortaCount Plus

Description:

Half Face 15- 100. Disposables 2- 5. Respirator fit testing ... Ultrafine Particles ( 0.1 micrometer diameter) Human Hair 120 m. Visible Dust 25 m ... – PowerPoint PPT presentation

Number of Views:383
Avg rating:3.0/5.0
Slides: 32
Provided by: shar276
Category:

less

Transcript and Presenter's Notes

Title: PortaCount Plus


1
PortaCount Plus
Andy Carling Sales Manager TSI Instruments Ltd
2
PortaCount Plus face fit tester
3
TSI
Who is TSI?
  • Instrumentation manufacturer
  • Founded 1961
  • Instruments for
  • Research
  • Industry
  • Defense

4
PortaCount Plus
  • Respiratory Protective Equipment
  • Whats the problem?
  • Why Fit Test?
  • Legislation
  • Qualitative Quantitative Fit Testing
  • PortaCount - How it works
  • Features/benefits
  • Disposables
  • Summary

5
Hierarchy of Control COSHH ACoP
  • Elimination
  • Substitution
  • Modify Process
  • Total Enclosure
  • Partial Enclosure/LEV
  • General Ventilation
  • PPE/RPE

6
What type of RPE?
  • All tight fitting RPE
  • Breathing Apparatus 350
  • Full Face 150
  • Half Face 15-100
  • Disposables 2-5

7
Respirator fit testing
  • Facepiece Seal
  • Greatest Source of Leakage
  • Depends on respirator DESIGN
  • Depends on proper respirator SIZE
  • Depends on proper DONNING/TRAINING
  • Depends on respirator CONDITION
  • Depends on the persons FACE

8
All respirators leak!!
  • Wrong size
  • Different shape face
  • Stubble/beards
  • Dentures
  • Scars/moles
  • Spectacles
  • Weight gain/loss
  • Too loose/tight
  • Accent/mood
  • Work rate

9
Why Fit Test?
  • Adequate/appropriate mask
  • Correct sizing
  • Train wearer
  • respiratory training
  • wear correctly without assistance
  • Documented results

10
HSE Information Document HSE282/28
  • Applied to Asbestos Nuclear industries
  • All users of tight fitting RPE

11
QLFT QNFT
  • Qualitative (QLFT) (without
    instruments)versus Quantitative (QNFT)(with
    instruments)

12
Qualitative fit Testing
  • Qualitative Fit Testing
  • Isoamyl Acetate (banana oil)
  • Saccharin (sweet taste)
  • Bitrex (bitter taste)

13
Quantitative Fit Testing
  • Quantitative Fit Testing
  • Using wearers own mask
  • Objective, definitive field test of respirator
    seal
  • Trains wearer to don the mask efficiently

14
HSE Protocol - HSE 282/28
  • Normal breathing
  • Deep breathing
  • Head side to side
  • Head up down
  • Bend touch toes
  • Talk out loud (Rainbow Passage)
  • Normal breathing

15
Protocol specifies
  • All exercises must be passed
  • Physical exercise should be included
  • exercise bike/treadmill/stepping exercise
  • 80 sec. exercise include a 60 second in mask
    sample
  • Fit testing is part of a comprehensive RPE
    programme

16
PortaCount Plus
  • Ambient/inside mask
  • Condensation Particle Counting
  • PASS/FAIL verdict
  • Easy to use software
  • Covers whole range of RPE from
  • BA to disposables
  • Documents results

17
Ultrafine Particles (lt 0.1 micrometer diameter)
Human Hair 120 µm
Visible Dust 25 µm
Non-visible Dust 10 µm
Common Allergens 5-10 µm
Metallic Fumes 0.3-1 µm
Ultrafine Particles lt 0.1 µm
18
Condensation Particle Counting
  • 100 year old concept
  • Grows microscopic
  • particles too small to see
  • using evaporated alcohol
  • Counted by laser, optics photometer

19
PortaCount Theory of Operation
20
PortaCount measurement
  • Measures ambient
  • concentrations of dust particles
  • Measures of concentrations inside mask
  • Ratio of the two is called a Fit Factor

21
Fit Factor
  • FF Ambient conc. (n/cc)
  • In-mask conc. (n/cc)
  • The higher the Fit Factor, the greater the level
    of protection

22
Fit Factor - Pass/Fail Levels
  • Breathing Apparatus 2000
  • Full Face 2000
  • Half Face 100
  • P3 Disposables 100
  • P1/P2 25

23
WWII Gas masks
  • Gas mask protection from WWII

24
How do we test disposables?
25
How do we test disposables?
26
How do we test disposables?
27
How do we test disposables?
28
How do we test disposables?
29
How do we test disposables?
Sampling
Pendant
P
C
ORTA
OUNT
30
Summary
  • RPE - last defence against hazardous substances
  • Company expense/investment
  • Why Fit Test?
  • Ensure right size/train the wearer document
    results
  • Legislation
  • Quantitative vs. Qualitative
  • PortaCount Plus complies with UK HSE legislation
  • Protects the
  • Employee from exposure to harmful substances
  • Employer from exposure to harmful courts

31
Questions?
QUESTIONS? acarling_at_tsi.com TSI UK Tel 44
(0)1275 847837 Fax 44 (0)1275 842437
Write a Comment
User Comments (0)
About PowerShow.com