T0 detector (since CR5)
  • W. H. Trzaskaon behalf of T0 team

HIP, Department of PhysicsUniversity of
Jyväskylä, Finland
2
Key events (since CR5)
  • Mar 05 integration test
  • May 05 electronics rev.
  • Jun 05 detector PRR
  • Aug 05 radiation hardness tests
  • Nov 05 full chain readout test
  • Feb 06 Electronics PRR
  • Mar 06 comprehensive tests of the fully
    assembled T0-C

3
Full chain readout testNovember 2005
  • T0 time and amplitude digitized and stored with
    the latest version of TOF hardware (HPTDC)
  • HV and laser attenuator under DCS
  • CFD DCS prototype tested
  • Next rounds of full chain tests
  • Jan Moscow
  • Feb/Mar Jyväskylä
  • Mar/June CERN
  • The final test 4 18 October 2006
  • Beam, T0-C, full set of electronics, readout, DAQ

4
Time resolution of a single PMT channel
Results from November 2005 full-chain readout
test at CERN
At high multiplicities the final T0 resolution
will be considerably better than that of a single
PMT
T0/V0 Shoebox works very well!
5
T0 DCS HV Sub-system
-StandardPVSS Framework OPS
FSM -Customized user panel
The system was working well
6
Transition from prototypes to VME modules went
smoothly
7
NIM-LVDS module
VHDCI 68-pin to VHDCI 68-pin cable for connection
with TRM
8
QTC (LED-CFD) test results
9
Shoebox (Heidelberg Jyväskylä)
T0/V0 preamp
analog power
disc.
DAC
10
T0/V0 Grounding Scheme(Commented by F. Formenti)
Floating P/A PS A1513B in SY1527 (Z04)
T0 HVPS 2 x A1733N in SY1527 (Z04)
V.Lyapin, 08/03/2006
12x 2 channels
10 V
10 V return
-10 V
-10 V return
10 V
  • Remarks
  • Connection between Shoebox amplifier and the
    Shoebox TRD digital part are the differential
    analog 100 Ohm line without common ground.
  • 2. To prevent cross-talk between channels and
    degradation of time resolution as a result, all
    patch-panels should be made from insulator.

10 V return
-10 V
8 those cables (V0T0)
-10 V return
- - - - - - - -
SAFETY EARTH
GND (Z04)
T0/V0 HVPS Adapter box in Z04, 4U
3 cables x 37 wires (V0T0)
GND (Z04)
for next Shoebox
Jumpers
GND (Z04)
4 wires in cable
Door patch panel.
1 LVPS cable per 1 Shoebox
T0/V0 LVPS Distributing Box in Z04, 6U
60 m
T0/V0 HVPS Adapter box in 019, 4U
GND (O18)
?
T0 FEE
RES
O18 LVPS patch panel, 4U
GND (O18)
GND (O18)
25 m
GND (Constr.) (Muon Absorber)
Shoebox, 1 of 10
8 (V0) or 12 (T0) Preamps per Shoebox
A side 5 Shoeboxes
GND (T0-A support)
LVPS
TRD Trigger Digital part
Solid electrically
Shoebox patch panel ( INSULATOR!!! )
C side
T0-A 12 Cherenkov detectors
Absorber patch panel ( INSULATOR!!! )
HVPS
Anode
One of 12 Cherenkov detectors
To the next Cherenkov detectors
PMT base
GND (Muon Absorber)
A side
GND (T0-A support)
T0-C mechanics
11