1GENERIC CONTROL OF ELECTRICAL ENVIRONMENT THROUGH
A WEBPAGE - IT Acumens. COM
2AIM
- The aim of the project is to control electrical
devices from a remote location through a web
page.
3SOFTWARE REQUIRED
- Java 2 Enterprise Edition(J2EE)
- Java Development Kit (JDK1.3)
- Apache Tomcat Server 1.4.1
- Internet Explorer
- Microsoft Access
- Microsoft Word( for documentation)
4HARDWARE REQUIRED
- Pentium III processor
- 64 MB RAM
- 10 GB Hard Disk
- Operating system windows 98
- PC Add-On card with PIA chip(s)
- An External port board.
- A dedicated designed interface
5SCOPE OF THE PROJECT
- CONTROL THROUGH IR
- Range is limited.
- Line of sight
- CONTROL THROUGH MICROWAVE
- Transmitter Receiver are costly.
6DESCRIPTION
- The electrical devices that are to be controlled
are connected to the home PC through a designed
dedicated interface.The status word of the
devices are posted to the PC through the PIA
present in the CPU of the home PC.The status word
is then uploaded to the web server.
7- At the server the individual status of the
devices are decoded and posted to the web page.A
remote user logs in and checks the current status
of the devices,if required the user changes the
status of the devices.The changed status is then
posted to the web server.The control word is then
encoded and posted to the home PC.The changed
status of the devices are reflected.
8(No Transcript)
9STATUS DETECTING CIRCUIT
10CONTROL CIRCUIT
118255 CHIP
- The 8255 chip is called a Programmable Interface
Adapter(PIA). - The three buses used for the interface are the
address bus,data bus and the control bus. - The 8255 contains three individual I/O ports.
- The microprocessor connects to certain pins on
the 8255.
12- Each port can be made to function either as Input
port or an Output port by setting the control
word. - Block B provides the logic for reading and
writing to each port of the chip. - The electrical status of the devices is
retrieved through the C program using the
port-based instructions. - The port-based instructions are
- _inp (port number)
- _outp (port number, value)
13- _inp is used to read the value from the port and
- _outp is used to write the value to the port.
14 START
SELECT THE DEVICES TO BE CONTROL
CONNECT THE DEVICES TO THE HARDWARE INTERFACE
A
15CONNECT THE INTERFACE TO THE PIA IN THE PC
USING THE PORTBASED INSTRUCTIONS RETRIEVE THE
STATUS WORD
IS THERE A CHANGE IN STATUS WORD
A
16UPLOAD THE CHANGED STATUS WORD TO THE SERVER
THE STATUS WORD IS DECODED AND IT IS STORED IN
DATABASE IN THE SERVER
THE REMOTE USERS AUTHENTICATION IS CHECKED
17 IS THE USER A AUTHENTICATED USER
NO
DIRECT THE USER TO A RE-LOGIN PAGE
IS THE USER ADMINISTRATOR
NO
DOES THE USER HAVE WRITE PERMISSION
YES
DIRECTED TO THE ADMINISTRATOR PAGE
C
18C
DIRECT TO THE CHANGE STATUS PAGE
DIRECT THE USER TO THE DISPLAY STATUS PAGE
THE USER CHANGES THE STATUS AND SUBMITS THE
FORM
O
THE ENCODED VALUE IS WRITTEN IN THE SERVER
19THE CONTROL WORD IS POSTED TO THE HOME PC
THE CONTROL WORD IS SENT TO THE OUTPUT PORT OF
PIA
THE CHANGED STATUS IS REFLECTED ON THE DEVICES
AT HOME.
O
STOP
20MODULES
- Retrieving status word from the electrical
device. - Posting the control word to the web server.
- User authentication and display of current
status. - User changing the status of the required device.
21- Control word stored in the home PC.
- Reflecting the changed status on device.
22ACQUIRING DEVICE STATUS
- The electrical devices are connected to the
interface designed. - The interface is connected to the home PC through
a Peripheral Interface Adapter. - The Status word is obtained through a flat cable
connected from the PC to the port board. - The value is then posted to the server.
23 DECODING
- A Servlet program is written to decode the
status word. - The current status of the device are posted to
the web page.
24ADMINISTRATOR
- The administrator has the rights to add/delete
the users from/to the list. - The administrator categorizes the users with two
permissions - Read permission.
- Read /write
permission. -
25REMOTE USER
- Authenticated users are allowed to access the web
page. - The users with read permission can only view the
current status of the device. - The users with read/write permission can view as
well as change the status of the device. - The changed status is stored in the web servers
database.
26TRANSACTION OF DATA
27ENCODING CONTROL WORD
- The status stored in the database are encoded
using a servlet program. - The encoded value is a decimal number which
varies from 0 to 255. - The encoded control word is posted from the web
server to the home PC.
28AT THE HOME PC
- The encoded control word is send to the interface
through a java program. - Decoding is done in the interface as a result of
which individual device status are changed.
29OUTPUT SCREENS
30LOGIN SCREEN
31CURRENT STATUS
32REQUIRED STATUS
33DATA STORED