1
New GXT2 10kVA
  • For X-Treme Density Environments

2
Liebert GXT2 10kVA
PREVIEW!
NEW !
  • 2 Models Tower and Rack
  • Tower version 1x1 and 3x1 selectable
  • Rack Version 3U 3U (Power Section Batteries)
  • Parallelable up to 3 modules
  • Expansion in Capacity or Redundancy
  • PFC Rectifier Input
  • Battery Extensions to up to 2 hours
  • Tower Version Optional Battery Charger

3
Liebert GXT2 10kVA RACK
PREVIEW!
4
Liebert GXT2 10kVA RACK
PREVIEW!
  • DSP Controller
  • VFI SS 111 Dynamic Performance (IEC 62040-3)

5
Liebert GXT2 10kVA RACK Input
PREVIEW!
  • Input voltage (V) 176 - 276V
  • 84V / 120V / 160 V
  • with output derating 50 / 75 / 90
  • Charger I/P voltage 100V 276V
  • Input Power Factor 0.97
  • Input THDi lt5

6
Liebert GXT2 10kVA Rack Other
PREVIEW!
  • AC/AC efficiency
  • 25 of load
    89
  • 50 of load
    91
  • 75 of load
    92
  • 100 of load
    92
  • Maximum noise level 55dBA
  • _at_ 1 meter front-side normal mode and battery mode

7
Liebert GXT2 10kVA TOWER
PREVIEW!
8
Liebert GXT2 10kVA TOWER
PREVIEW!
  • DSP Control
  • VFI SS 111 Dynamic Performance (IEC 62040-3)
  • Available also with Output Transformer
  • GXT2-10000T220

9
Liebert GXT2 10kVA TOWER
PREVIEW!
LCD Display
10
Liebert GXT2 10kVA TOWER Input
PREVIEW!
  • Input voltage (V) 176 - 276V for 1x1
  • 294 - 478V for 3x1
  • Charger I/P voltage 100V 276V
  • Input Power Factor 0.97 1x1 0.95 3x1
  • Input THDi lt5 for 1x1 lt10 for 3x1

11
Liebert GXT2 10kVA TOWER Charger
PREVIEW!
  • Charger output current 1.2A
  • With Optional Charger Board 4.0A
  • internal option only on GXT2-10000T230
  • Compare that to current 1.2A standard charger

12
Liebert GXT2 10kVA TOWER Other
PREVIEW!
  • AC/AC efficiency
  • 25 of load
    87
  • 50 of load
    91
  • 75 of load
    92
  • 100 of load
    92
  • Maximum noise level 50dBA
  • _at_ 1 meter front-side normal mode and battery mode

13
Liebert GXT2 10kVA Tower and Rack
PREVIEW!
  • Simultaneous Communications
  • INTELLISLOT in-built Relay Card
  • Parallel Connection
  • Only need optional paralleling cable
  • UP to 3 modules
  • Power ? 30kVA
  • Redundancy 11, 21 or 12
  • 1010kVA, 2010kVA

14