Title: NFIRS 3 Structure Fire Module
1NFIRS 3 Structure Fire Module
2Objectives
- The participants will be able to
- describe when the Structure Fire Module is to be
used - demonstrate the completion of various sections of
the Structure Fire Module for different scenarios
3Structure Fire Module
- Used to supplement Fire Module
- Incident types 111 and 120s
4I1 - Structure Type ?
- Identifies a specific property type of a
structure - Continue only if building was enclosed or a
portable/mobile structure
5I2 - Building Status ?
- Identifies the operational status of the
building at the time of the incident
6I3 - Building Height ?
- Identifies the total number of stories (floors)
at or above grade level and the total number of
stories below grade in the fire building - Do not count normally inaccessible attics, attics
with less than standing height, or a roof as a
story
7I4 - Main Floor Size ?
- Identifies the floor size - can use
- total square feet
- length x width
8J1 - Fire Origin ?
- Identifies the story (floor level) where the fire
originated within the building - Identifies floor levels above or below grade
9J2 - Fire Spread ?
- Identifies the extent of flame damage within the
structure - Flame damage is area actually burned or charred
- Does not include heat, smoke, or water damage
10J3 - Stories Damaged by Flame
- Identifies the number of stories (floor levels)
damaged by fire by percent of damage - Do not include damage from heat, smoke, or water
damage
11K - Material Contributing Most to
Flame Spread
- K1 identifies the item contributing most to flame
spread, if different from the item first ignited - K2 identifies the type of material contributing
most to flame spread, if different than the type
of material first ignited
Go to Section L if there was no flame spread, or
this is the same as material first ignited or
unable to determine
12L1 - Presence of Detectors ?
- Captures data on detectors if they were present
in the general area of the fire - Required if the fire was within the area covered
by the detector. - If not, skip to Section M
13L2 - Detector Type
- Identifies the type of fire detection system
that was present in the area of fire origin
14L3 - Detector Power Supply
- Identifies the type of power supplying the
detector
15L4 - Detector Operation
- This data element identifies whether or not the
detection equipment worked
16L5 - Detector Effectiveness
- Identifies the effectiveness of the fire
detection equipment in alerting the occupants - Required if the detector operated
17L6 - Reason for Detector Failure
- Identifies why the detector failed to operate or
did not operate properly - Required if the detector failed to operate
18M1- Presence of Automatic Extinguishment System
- Identifies the presence of automatic
extinguishment system (AES) - If AES is present complete the rest of Section M
19M2 - Type of Automatic Extinguishment System
- Identifies the type of AES that was present in
the area of fire origin
20M3 - Automatic Extinguishment System Operation
- Identifies the operation and effectiveness of
AES in the area of fire origin
21M4 - Number of Sprinkler Heads Operating
- Identifies the number of sprinkler heads that
operated during the fire
22M5 - Automatic Extinguishment System Failure
- Identifies the reason why the AES failed to
operate
23Scenario 3
24Summary
- The Structure Fire Module (NFIRS 3) is used in
conjunction with the Fire Module to gather
information about larger fire incidents which
involve buildings - The Structure Fire Module clarifies information
about - the buildings involved in the fire
- how the fire started
- detection and automatic suppression equipment
25Questions?