Title: NFIRS 3 Structure Fire Module


1
NFIRS 3 Structure Fire Module
2
Objectives
  • The participants will be able to
  • describe when the Structure Fire Module is to be
    used
  • demonstrate the completion of various sections of
    the Structure Fire Module for different scenarios

3
Structure Fire Module
  • Used to supplement Fire Module
  • Incident types 111 and 120s

4
I1 - Structure Type ?
  • Identifies a specific property type of a
    structure
  • Continue only if building was enclosed or a
    portable/mobile structure


5
I2 - Building Status ?
  • Identifies the operational status of the
    building at the time of the incident

6
I3 - Building Height ?
  • Identifies the total number of stories (floors)
    at or above grade level and the total number of
    stories below grade in the fire building
  • Do not count normally inaccessible attics, attics
    with less than standing height, or a roof as a
    story

7
I4 - Main Floor Size ?
  • Identifies the floor size - can use
  • total square feet
  • length x width

8
J1 - Fire Origin ?
  • Identifies the story (floor level) where the fire
    originated within the building
  • Identifies floor levels above or below grade

9
J2 - Fire Spread ?
  • Identifies the extent of flame damage within the
    structure
  • Flame damage is area actually burned or charred
  • Does not include heat, smoke, or water damage

10
J3 - Stories Damaged by Flame
  • Identifies the number of stories (floor levels)
    damaged by fire by percent of damage
  • Do not include damage from heat, smoke, or water
    damage

11
K - Material Contributing Most to
Flame Spread
  • K1 identifies the item contributing most to flame
    spread, if different from the item first ignited
  • K2 identifies the type of material contributing
    most to flame spread, if different than the type
    of material first ignited

Go to Section L if there was no flame spread, or
this is the same as material first ignited or
unable to determine
12
L1 - Presence of Detectors ?
  • Captures data on detectors if they were present
    in the general area of the fire
  • Required if the fire was within the area covered
    by the detector.
  • If not, skip to Section M

13
L2 - Detector Type
  • Identifies the type of fire detection system
    that was present in the area of fire origin

14
L3 - Detector Power Supply
  • Identifies the type of power supplying the
    detector

15
L4 - Detector Operation
  • This data element identifies whether or not the
    detection equipment worked

16
L5 - Detector Effectiveness
  • Identifies the effectiveness of the fire
    detection equipment in alerting the occupants
  • Required if the detector operated

17
L6 - Reason for Detector Failure
  • Identifies why the detector failed to operate or
    did not operate properly
  • Required if the detector failed to operate

18
M1- Presence of Automatic Extinguishment System
  • Identifies the presence of automatic
    extinguishment system (AES)
  • If AES is present complete the rest of Section M

19
M2 - Type of Automatic Extinguishment System
  • Identifies the type of AES that was present in
    the area of fire origin

20
M3 - Automatic Extinguishment System Operation
  • Identifies the operation and effectiveness of
    AES in the area of fire origin

21
M4 - Number of Sprinkler Heads Operating
  • Identifies the number of sprinkler heads that
    operated during the fire

22
M5 - Automatic Extinguishment System Failure
  • Identifies the reason why the AES failed to
    operate

23
Scenario 3
24
Summary
  • The Structure Fire Module (NFIRS 3) is used in
    conjunction with the Fire Module to gather
    information about larger fire incidents which
    involve buildings
  • The Structure Fire Module clarifies information
    about
  • the buildings involved in the fire
  • how the fire started
  • detection and automatic suppression equipment

25
Questions?