Use of the Labnet Micropipettor
2
Purpose of the Pipettor
  • Biotechnologists use a pipettor to transfer
    precise amounts of liquids from one container to
    another.
  • The measurements are in microliters 1 ml1000 µl.

Use of the Labnet Micropipettor
3
Care of the Pipettor
  • Misuse of the pipettor can result in incorrect
    measurements affecting your investigation.
  • Do not drop the pipettor.
  • Do not adjust the volume to less than 2 µl.

Use of the Labnet Micropipettor
4
Parts of the Pipettor
1
1
2
  • 1) yellow pushbutton
  • 2) calibration knob
  • 3) digital volume display
  • 4) barrel
  • 5) disposable pipette tip
  • 6) tip ejector

6
3
6
6
3
4
4
5
5
Use of the Labnet Micropipettor
5
Volume AdjustmentStep 1
  • In the display window are three vertical numbers.
  • The top number is tens µl (10.0).
  • The middle number is ones µl (02.0).
  • The bottom number tenths µl (00.9).

Use of the Labnet Micropipettor
6
Volume AdjustmentStep 2
  • Set the pipettor to the desired volume by turning
    the calibration knob until the volume display
    reads the desired numbers.
  • 7.5 µl would read from top to bottom in the
    display window 0
    - tens 7
    - ones .5 - tenths

Use of the Labnet Micropipettor
7
Transferring LiquidsStep 1
  • Adjust the pipettor to the desired volume.
  • Hold the pipettor so the display is facing the
    user and the thumb can easily depress the yellow
    pushbutton.

Use of the Labnet Micropipettor
8
Transferring LiquidsStep 2
  • Open the box of yellow pipette tips supplied by
    the Office of Biotechnology.
  • Place the pipette cone (end) into one of the tips
    and press down firmly.
  • NEVER USE THE PIPETTOR WITHOUT A TIP!

Use of the Labnet Micropipettor
9
Transferring LiquidsStep 3
  • Lift the pipettor and attached tip away from the
    tip box.
  • Depress the pushbutton to the first stop before
    placing the pipette tip in the liquid.
  • Place the tip in the liquid.

Use of the Labnet Micropipettor
10
Transferring LiquidsStep 4
  • Slowly release the pushbutton and draw the liquid
    into the tip.
  • Remove the tip from the liquid and visually check
    for liquid in the tip.

Use of the Labnet Micropipettor
11
Transferring LiquidsStep 5
  • Place the tip into the container which is to
    receive the liquid.
  • Slowly depress the pushbutton as far as it can
    go.
  • With the pushbutton fully depressed, withdraw the
    tip.

Use of the Labnet Micropipettor
12
Transferring LiquidsStep 6
  • Press down on the tip ejector button to eject the
    tip.
  • Dispose of the tip in an appropriate container.