Description:

Water Rate Oil Rate Water cut Choke. Before: 797 bwpd 100 bopd 89% Open ... Water Rate Oil Rate Water cut Choke. Before: 2041 bwpd 305 bopd 87% Open ... – PowerPoint PPT presentation

Number of Views:175
Avg rating:3.0/5.0
Slides: 15
Provided by: c4communic
Category:

less

Transcript and Presenter's Notes

Title: AquaConTM Selective Permeability Modifier For Water Control


1
(No Transcript)
2
AquaConTMSelective Permeability ModifierFor
Water Control Production Enhancement
  • BJ Services Company

3
AquaConTM
  • Newest BJS Relative Permeability Modifier (RPM)
  • Proprietary technology
  • Exclusive to BJ Services

4
AquaConTM Unique Features
  • Effective in both sandstones and carbonates
  • Substantially reduces matrix water flow without
    reducing oil or gas flow
  • Compatible with high salinity brines and divalent
    ions (e.g., Ca2)

5
AquaConTM Multiple Treatment Applications
  • Oil and gas wells
  • Water flood injection profile modification
  • ConformStim
  • ConformFrac (fluid efficiency enhancement)
  • ConformAcid (diversion and water control)

6
AquaConTMLaboratory Core Flow Test Results
7
AquaConTM Core Test EvaluationLow Permeability
Carbonate Application5 gpt AquaCon at 150 0F
8
AquaConTM Core Test EvaluationGas Well Treatment
Application
  • Perm before Perm after
  • Fluid treatment (mD) treatment (mD)
  • 2 KCl 2.6 0
  • Gas 16.0 10.1
  • 2 KCl 2.2 0 (0.078 )
  • 6 AquaCon
  • after extended flow at high dP (80 psi)

9
AquaConTM in Spectra Frac G 4000 Leak-off Test
Evaluation
10
AquaConTMField Treatment Results
11
AquaConTM Matrix Treatment ResultsOffshore West
Africa Sandstone (k 500-700 md)
  • Well 1 (3 AquaCon)
  • Water Rate Oil Rate Water cut
    Choke
  • Before 797 bwpd 100 bopd 89
    Open
  • After 1 mo 277 108 72 26/64
  • Well 2 (3 6 AquaCon)
  • Water Rate Oil Rate Water cut
    Choke
  • Before 2041 bwpd 305 bopd 87
    Open
  • After 2.5 mo 1533 567 73 Open

12
AquaConTM Matrix Treatment ResultsOnshore
Indonesia (k 940 md)
  • Water Rate Oil Rate Water
    cut Pump
  • Before 1032 bwpd 66 bopd 94
    DN-450
  • After 1 week 718 98 88 DN-750
  • After 5 weeks 557 287 66
  • After 7 weeks 372 436 46
  • After 12 weeks 444 364 55
  • Treatment 6 AquaCon
  • Temperature 200 0F
  • Perforated interval 20 ft
  • Treatment radius 7 ft

13