E166 Cables: Issues - PowerPoint PPT Presentation

1 / 10
About This Presentation
Title:

E166 Cables: Issues

Description:

long route: old E144 cryogenics penetration on FFTB south wall near dump ... Scintillator Paddle BR. 3(e7) 9(e7) CsI (PMT pdiode) BR. 1(e7) 1(e7) Silicon-G10 BR ... – PowerPoint PPT presentation

Number of Views:22
Avg rating:3.0/5.0
Slides: 11
Provided by: SLAC
Category:
Tags: cables | e166 | issues | paddle

less

Transcript and Presenter's Notes

Title: E166 Cables: Issues


1
E166 CablesIssues Requirements
  • Gary Bower
  • October 25, 2003
  • E166 Collaboration Meeting_at_SLAC

2
Cable routes
  • From/To
  • IP1/Experimental area to 406/407
  • Via
  • long route old E144 cryogenics penetration on
    FFTB south wall near dump
  • short route penetration on FFTB north wall near
    entry.
  • Not much cable room in short route.

3
Distances
  • Short route
  • IP1 to 406/407 20-30m.
  • Experimental area to 406/407 55-70m.
  • Long route
  • IP1 to 406/407 100-110m.
  • Experimental area to 406/407 65-75m.

4
Nomenclature
  • i6 IP1 406 long route.
  • i7 IP1 407 long route.
  • e6 Experimental area 406 long route.
  • e7 Experimental are 407 long route.
  • i6s IP1 406 short route.
  • i7s IP1 407 short route.
  • ER Experimental run.
  • BR Background test run ER.

5
Cables Detectors
Detector Signal(route) //Foam8// HV(route) //RG-59//
SiWCal BR 12(e7) 2(e7)
Silicon-G10 BR 1(e7) 1(e7)
CsI (PMTpdiode) BR 9(e7) 3(e7)
Scintillator Paddle BR 1(e7) 1(e7)
Aerogel BR 2(e7) 2(e7)
PCAL(or equivalent) BR 4 (i7) 1(i7)
Clive BR 0 0
CsI ER 16-128(e7) 17(e7)
6
Cables Experimental devices - 1
  • 2x Fe absorbers(for each) ER
  • 2x Hall probes (RG59) e7
  • 5x pickup coils(RG59) e7
  • 2x 100A 30V DC power (2C2T6V) e6
  • Spectrometer magnet ER
  • 2x 100A 30V DC power (2C2T6V) e6

7
Cables Experimental devices - 2
  • Undulator pulser ER
  • 8A 1kV DC power (???) i6s
  • Current monitor (Foam8) i6
  • Trigger signal (Foam8) i6
  • Tunnel cpu, camera BR
  • ethernet (4PR20IS?) i7
  • Spares BR
  • 10x HV (RG-59) i7
  • 10x signal(Foam8) i7

8
Cables Accelerator Devices - 1
  • 3 strip line BPMs(for each) BR
  • 4x signal (RG-223) i6s
  • Wire scanner BR
  • motor (12C18) i6
  • LVDT (4PR24IS) i6
  • Ion Chamber BR
  • signal (Foam8) i7
  • HV (RG-59) i7

9
Cables Accelerator Devices - 2
  • Photon collimator(At) mover BR
  • 2x motor (12C18) i6
  • 2x LVDT (4PR24IS) i6
  • 3x Profile monitor cameras(for each) BR
  • video signal (RG-59) 2xe7,i7
  • control (19C18TR) 2xe6, i6
  • AC power 2xe6, i6?

10
Cables Accelerator Devices - 3
  • Table mover BR
  • 4x motor (12C18) i6
  • 4x LVDT (4PR24IS) i6
  • HSB2 BR
  • 2x DC power (2C10T6V) i6
  • Positron target ER
  • in/out, status (RJ-11) e6
Write a Comment
User Comments (0)