Journal reading - PowerPoint PPT Presentation

1 / 22
About This Presentation
Title:

Journal reading

Description:

To evaluate time effect and lavage device in wound irrigation by Bioluminescent ... Pulsed lavage system is more effective than bulb syringe and may allow less ... – PowerPoint PPT presentation

Number of Views:25
Avg rating:3.0/5.0
Slides: 23
Provided by: chingyi4
Category:

less

Transcript and Presenter's Notes

Title: Journal reading


1
Journal reading
  • Present R3???
  • Direct Dr. ???

2
  • Comparison of Bulb Syringe and Pulsed Lavage
    Irrigation with Use of a Bioluminescent
    Musculoskeletal Wound Model
  • J Bone Joint Surg Am. 2006882167-2174.
  • Early Wound Irrigation Improves the Ability to
    Remove Bacteria
  • J Bone Joint Surg Am. 2007891723-1726.

3
Management of open fracture
  • Debridement as early as possible
  • Irrigation
  • Internal fixation or external fixation
  • Check neurovascular injury

4
Irrigation
  • Timing
  • Fluid Volume
  • Fluid Type
  • Sterile N/S
  • Antiseptic soap. Iodine
  • Antibiotics
  • Delivery method
  • Pulsed lavage
  • Bulb syringe

5
Objective
  • To evaluate time effect and lavage device in
    wound irrigation by Bioluminescent
    Musculoskeletal Wound Model.

6
Material and Method
  • Bacteria
  • Genetic engineering Pseudomonas aeruginosa
  • Bioluminescent bacteria emit light in proportion
    to their number.
  • Wound creation
  • 12 goat
  • Complex open wound over muscle, fasciae,
    periosteum and bone
  • inoculated with 1 mL of gt108 CFU/mL of
    Pseudomonas aeruginosa

7
Material and Method
  • Pulsed lavage and bulb syringe
  • 3L, 6L,9L
  • Different tissue response
  • Early irrigation
  • 3hrs, 6hrs, 9hrs
  • Pulsed lavage, 6L

8
Wound creation
9
(No Transcript)
10
Pulsed lavage
  • Minimal set up - spike and shoot
  • Concurrent suction with soft cone splash shield
    for optimal fluid containment without damaging
    soft tissue
  • Ergonomic shape to reduce muscle fatigue
  • Completely disposable

11
Result (Pulsed vs Bulb syringe)
12
Result (Pulsed vs Bulb syringe)
13
Result (Pulsed vs Bulb syringe)
14
Result (Early irrigation)
15
Result (Early irrigation)
16
Discussion
  • Pulsed lavage vs Bulb syringe
  • Pressure difference
  • Local inflammation
  • Destroy viable tissue
  • Propagate bacteria into tissue
  • CORR 2005.439.27-31

17
Discussion
  • Time effect in the management of open fracture
  • Antibiotics era
  • Selection bias
  • No prospective randomized controlled study.

18
Discussion
19
Biofilm formation
20
Biofilm formation
21
Limitation
  • Animal study
  • Small case number
  • Pathogen
  • Reduce bacteria count reduce infection rate???
  • Role of debridement

22
Conclusion
  • Pulsed lavage system is more effective than bulb
    syringe and may allow less irragation volume used
  • Early irrigation remove more bacteria
Write a Comment