Precise aK Measurement in 197Pt - PowerPoint PPT Presentation

1 / 20
About This Presentation
Title:

Precise aK Measurement in 197Pt

Description:

Precise aK Measurement in 197Pt. A Test of ... 0.7mg 196Pt dissolved in a solution of aqua-regia ... Placed on thin layer of Mylar. Thermal Neutron Activation ... – PowerPoint PPT presentation

Number of Views:15
Avg rating:3.0/5.0
Slides: 21
Provided by: jbng
Category:

less

Transcript and Presenter's Notes

Title: Precise aK Measurement in 197Pt


1
Precise aK Measurement in 197Pt
  • A Test of Internal Conversion Theory

Mark Hernberg Advisor Dr. John C. Hardy Mentor
Dr. Ninel Nica
2
What Is Internal Conversion?
3
Internal Conversion Coefficient
  • ICCs are used in the study of
  • Nuclear decay schemes
  • Spin and parity assignments,
  • Transition rates
  • Branching ratios
  • Detector efficiency calibration

4
(No Transcript)
5
197mPt Decay
CITATION Nuclear Data Sheets (2005)
From NNDC(BNL) Program ENSDAT
6
Source Preparation
  • Homogeneous Layer of Sample
  • 0.7mg 196Pt dissolved in a solution of aqua-regia
  • 96 enriched sample, naturally occurring is only
    25
  • Heated dried to solidify
  • Placed on thin layer of Mylar
  • Thermal Neutron Activation
  • At TRIGA nuclear reactor here on campus
  • Activation time of 4 hours

7
Oops Activation Problems
  • Long sample activation time resulted in an
    excessive level of both impurities and activity.

197mPt
197Pt
8
Data Collection
  • 17 spectra collected from
  • 3 hours to 9 days after activation
  • Over 700 million counts
  • Average of over 900 counts/sec!
  • Relative photopeak efficiencies calibrated to
    0.15

9
Detector Info
Source
  • 3 Main Events in Detector
  • Photoelectric Effect
  • Compton Scattering
  • Pair Production

10
Spectral Analysis
Spectrum 1 8.28 minute run time, 55.4 live
time, 1.2 million total counts
11
Spectral Analysis
Spectrum 17 22.1 hour run time, 97.6 live time,
1 million total counts
12
Impurity Analysis
13
Impurity Analysis
  • Check known common impurities-
    like 197Au
  • Make educated guesses
  • Known Gammas for
  • 124Sb
  • Energy (keV) Ig()
  • 602.7 98.2
  • 722.78 10.8
  • 1690.9 47.7
  • Found Gammas
  • Energy (keV) Ig()
  • 602.5 97.5
  • 722.6 10.4
  • 1691.4 47.1

TORI Data from LBNL website (1999)
14
Spectral Analysis
15
Spectral Analysis
197Au
191m Hg
191m Hg
16
Peak Analysis
17
aK Calculation
  • Full Formula

aK K-shell ICC wK fluorescence yield
0.959(4) NK, Ng peak area eK, eg detector
efficiency
E. Schönfeld, H. Jaben, NIM A 369 (1996) 527.
18
Preliminary Results
19
To Infinity and Beyond
  • Prepare another 196Pt sample, this time with the
    correct activation level.
  • Repeat data collection analysis process
  • Determine aK to lt1 uncertainty.

20
Acknowledgements
  • Dr. John C. Hardy
  • Dr. Ninel Nica
  • Victor Iacob
Write a Comment
User Comments (0)
About PowerShow.com