Title: Lead and Copper Program Changes


1
Lead and Copper Program Changes
  • Todd Ritter
  • Kentucky Division of Water

2
About the Lead and Copper Regulation
  • Purpose of the regulation is to protect public
    health by minimizing lead and copper levels in
    drinking water
  • Applies to all community and non-transient
    non-community water systems
  • No maximum contaminant levels. Instead lead and
    copper have action level exceedances.

3
Initial Monitoring
  • Must sample for 2 consecutive 6 months at the
    maximum number of samples. Jan.-June and
    July-December monitoring periods.
  • Population based monitoring.
  • Monitoring must be sampled in the distribution
    system at approved lead/copper sites
  • Approved lead/copper sites must have Tier and
    Tier type information.

4
Population Information
  • System Size No. of Samples
  • gt100,000 100
  • 10,001-100,000 60
  • 3,301-10,000 40
  • 501-3,300 20
  • 101-500 10
  • lt100 5

5
Reduced Monitoring
  • 1st stage of reduced monitoring requires 3
    consecutive years of monitoring, sampling half
    the initially required samples
  • 2nd stage of reduced monitoring requires sampling
    every three years
  • For reduced monitoring, all samples must be taken
    during June-September monitoring period.

6
Pop. Info. Reduced Monitoring
  • System Size No. of Samples
  • gt100,000 50
  • 10,001-100,000 30
  • 3,301-10,000 20
  • 501-3,300 10
  • 101-500 5
  • lt100 5

7
Action level exceedances
  • Lead action level - .015 mg/l
  • Copper action level 1.3 mg/l
  • To determine whether an action level has been
    exceeded, the value at the 90th percentile of all
    samples is compared against its respective
    action level.

8
Calculating 90th percentiles
  • For systems collecting more than 5 samples
  • Place results in ascending order (low to high)
  • Assign each sample a number, 1 for the lowest
    value
  • Multiply the total number of samples by .9 (ex.
    20 samples x .9 18, so sample 18 will be your
    90th percentile)
  • Compare 90th percentile to respective action
    level

9
Calculating 90th percentiles
  • For systems required to collect 5 samples
  • Place results in ascending order.
  • Take the average of the 4th and 5th highest
    sample. This is your 90th percentile.
  • Compare 90th percentile against respective action
    level.

10
Do I have an exceedance?
  • EPAs policy is to
  • Round down to the nearest whole number if your
    decimal is 0.4 or lower.
  • Example 90th percentile of lead is .0153 mg/l,
    which means your result would be calculated as
    .015 mg/l which is not an exceedance.
  • 2. Round up to the nearest whole number if your
    decimal is 0.5 or higher.
  • Example 90th percentile of copper is 1.36 mg/l
    which would means your true result would be 1.4
    mg/l. This is an exceedance.

11
Reporting Requirements
  • Lead and copper results are not sent to DOW by
    the lab. Results should be signed by a water
    supply representative.
  • 90th percentiles will now be calculated by the
    water system and sent with the results. The 90th
    percentiles are a required element for a systems
    Consumer Confidence Report (CCR). An Excel
    spreadsheet is available from the state for
    calculations. The public water system has always
    been responsible for these calculations per the
    regulation.
  • The DOW is asking systems to send in lead and
    copper results as soon as they are received by
    the water system. This is due to the remedial
    measures required when a system has an action
    level exceedance. We recommend submittal no later
    than October 10th. Regulatory deadline is by
    January 10 the following year.

12
Sample site information
  • Community Systems
  • Tier 1 sampling sites are single family
    structures with copper pipes with lead solder
    installed after 1982 and/or that are served by a
    lead service line.
  • Tier 2 sampling consists of buildings,
    including multi-family residences with copper
    pipes with lead solder installed after 1982 or
    contain lead pipes and/or that are served by a
    lead service line.
  • Tier 3 sampling sites are single family
    structures with copper pipes having lead solder
    installed before 1983.

13
Sample Site Information
  • Non-Transient Non-Community Systems
  • Tier 1 sampling sites consist of buildings with
    copper pipes with lead solder installed after
    1982 or contain lead pipes and/or that are
    served by a lead service line.
  • Tier 2 sampling sites consist of buildings with
    copper pipes with lead solder installed before
    1983.
  • Tier 3 not applicable

14
Sample site information
  • Lead and copper sites must have Tier and Tier
    type information to be considered a true
    lead/copper site. Any site used as a lead/copper
    site that is missing that information will not be
    accepted.
  • Letter sent out on January 18, 2006 asked that
    all water systems take a closer look at their
    lead/copper sample sites. Corrections or
    additional sites should be sent to my attention
    via mail, email or fax.

15
Copper action level exceedance
  • Submit the result of a copper test on source
    water
  • Perform Water Quality Parameter testing on the
    plant tap and 3 sites in the distribution system.
  • Submit an optimal corrosion control treatment
    recommendation
  • Install source water treatment, if needed

16
Lead action level exceedance
  • Submit result of lead test on source water
  • Within 60 days of the exceedance perform public
    education. Public Education templates are
    included with letter notifying system of the
    exceedance
  • Perform Water Quality Parameter testing on the
    plant tap and 3 sites in the distribution system.
  • Submit an optimal corrosion control treatment
    recommendation
  • Install source water treatment, if needed
  • Replace lead service lines

17
Water Quality Parameters
  • Who collects them?
  • Systems with a population greater than 50,000
  • Systems that have exceeded the lead or copper
    action level.
  • The reasoning behind submitting lead and copper
    results is that in case of an exceedance, water
    quality parameters should be taken in the same
    monitoring period as the lead and copper results.

18
Public Education requirementsPublic Education
Requirements
  • Community Water Systems
  • Insert notices in each customers water utility
    bill
  • Deliver pamphlets/brochures to facilities that
    provide services for pregnant women or children
  • Submit information to the editorial department of
    the major daily or weekly newspapers
  • Deliver public service announcements to radio and
    television stations
  • A community water system must repeat delivery
    every 6 months for public service announcements,
    and every 12 months for other forms of delivery,
    for as long as the system exceeds the lead action
    level.

19
Public Education Requirements
  • Non-transient non-community water systems
  • Post informational posters in public places or in
    common areas of buildings served by the system
  • Distribute informational pamphlets and or
    brochures to each person served by the system
  • Must repeat this annually for as long as it
    exceeds the lead action level

20
Treatment or Source changes
  • Treatment or source changes must be pre-approved.
  • If a system is on a reduced monitoring schedule
    and a new source is approved, the system will be
    returned to standard monitoring

21
Lead Service Line Replacement
  • If treatment is not effective in reducing lead
    levels, systems with lead service lines must
    replace at least 7 percent of their lines
    annually
  • The state can also require systems to begin lead
    service line replacement if they do not meet
    their deadline for installing corrosion control
    or source water treatment
  • Systems can discontinue lead service if they are
    at or below the lead action level for 2
    consecutive monitoring periods.

22
Necessary Info for location code
  • Name
  • Full Address
  • Tier and Tier Type Information

23
Things to Remember
  • Tier 1 sites are the preferred lead/copper
  • sites. If an insufficient number exist then
    Tier 2 followed by Tier 3
  • If you have lead service lines in your
    distribution system , you should collect at least
    half of your samples from sites served by lead
    service lines
  • You should identify more sampling sites than the
    number of samples you are required to collect.

24
Continued
  • If you do not have the required number of
    sampling sites, you may collect more than one
    sample from the same location, on different days
  • Samples must be 1 liter in volume and taken from
    an interior tap where the water has stood in the
    pipes for at least 6 hours
  • You should collect samples early enough in the
    monitoring period in case WQP are required

25
Continued
  • You must collect source water samples if you
    exceed lead and copper action levels
  • If you serve 50,000 or fewer people, you can stop
    corrosion control treatment steps whenever your
    90th percentile lead and copper levels are at or
    below their action levels for 2 consecutive
    6-month monitoring periods. You must recommence
    these steps if you exceed either action level
    again,

26
Questions?
  • Contacting me
  • Phone (502)-564-3410 ext. 586
  • Email todd.ritter_at_ky.gov
  • Fax (502)-564-9899