Title: RWD heatpump controllers
1RWD Heat Pump controllers
RWD Heat Pump Controllers
2Heat pump Controllers
- Why?
- Rapid growth in the use of heat-pump technology
throughout North America - Sell applications, not components
- Increase sales of valves and damper actuators
- Wholesalers purchasing competitors controllers
(T775, A350) - Increase RWD range
- RWD suitable for commercial applications
3RWD44U
- Standard RWD design
- New LCD with clear heat/cool output status
- New Digital input options
- Alarm inputs
- Suitable for Ni1000, Pt1000 or 0-10vdc inputs
- Heat/cool or reversing valve/compressor config
- Flexible output delay times
- Usable defaults
-
Standard model
Our standard solution for commercial heat
pumps. Easy and flexible settings
4RWD Heat pump controllers
Standard model
- RWD44U
- Standard RWD format with LCD
- Button or software tool parameter setting
- (4) digital outputs configurable
- Air to Air / Air to Water Heat-pumps
- Suitable for single, dual and triple
compressor units - Auxiliary functions applicable to Heat-pumps
- 24vac
5RWD44U Internal diagram
Removable terminals are also labeled. Disconnect
when commissioning
6Two-stage heating and cooling
7Three stage (CR)compressor - (RV)reversing valve
S1 D/N C/O X1 main sensor X2 Remote setpoint
8RWD44U/45U Aux Functions Digital Input options
- Auxiliary Functions
- Remote setpoint
- Compensation shift
- Two sensor averaging
- Winter/summer setpoint selection
- Sensor select
- Active input
- Digital input options
- Standby (on/off)
- Alarm
- Filter alarm
- Day/night setpoints
Refer to application chart for combinations
9RWD44U/45U Digital input options
Standby (on/off)
SEH62.1U
10RWD44U/45U Digital input options
Alarm External shutdown, Flow switch,
smoke, Common alarm from heat pump
Alarm
11RWD44U/45U Digital input options
Filter Alarm Avoid heat pump breakdowns Warning
for maintenance personnel to change filter
12RWD44U/45U Digital input options
Day Night Setpoints Keep internal temperatures
within acceptable limits during unoccupied periods
SEH62.1U
13RWD44U/45U Aux functions
Remote setpoint
Setpoint adjustment should be mechanically
limited
14RWD44U/45U Aux functions
Compensation shift Enhanced comfort and energy
savings
X2
SP?
X2
SP?
15RWD44U/45U Aux functions
Sensor averaging In some areas the temperature
may vary from one location to another.
X1
X2
16RWD44U/45U Aux functions
Sensor Select Flexible solution for special
applications. Typical example is a general office
area with a seldom used meeting room.
X1
X2
X1
X2
Office area
Meeting room
OR
17RWD44U/45U Aux functions
Winter/Summer setpoint selection (Digital) Heat
pumps for 2-pipe systems (return water
temperature control)
SP 76
SP 72
18RWD44U/45U Aux functions
Winter/Summer setpoint selection (Analog) Heat
pumps for 2-pipe systems (return water
temperature control)
SP 72
SP 76
19RWD45U
- Standard RWD44U design
- Same auxiliary functions
- LCD with monitoring of all inputs/outputs
- Three universal inputs
- New OpenAir economizer control
- No need for hi/low limit thermostats
- A single active O/A sensor can be used for a
group of controllers -
Economizer model
OpenAir economizer or RWD44U 2nd
independent universal modulating loop.
20RWD Heat pump controllers
Economizer model
- RWD45U
- Standard RWD44U format with LCD
- Button or software tool setting
- Air to Air / Air to Water Heat-pumps
- (4) DOs and (1) AO configurable
- Suitable for single, dual and triple compressor
units - Economizer control or 2nd independent (Y) loop
- New OpenAir economizer sequence
- 24vac
21RWD45U Internal diagram
22RWD45U - OpenAir economizer control
Remember the days when you could just open a
window?
Why use cooling energy when the outside air
temperature is suitable for cooling? The OpenAir
economizer feature simply shifts the 1st cooling
stage and replaces it with a 0 -10vdc cooling
output. This occurs only when cooling is required
and the outside temperature is suitable.
Introduce outside air via damper
actuators. Economizer control is not a new
innovation, however the RWD45U OpenAir solution
is an easily implemented and understood concept.
Affordable
23RWD45U - OpenAir economizer control
Eco Parameters Min X3 limit Max X3 limit Eco -
Xp Y min Y max
Economy mode is active only when cooling is
required and the X2 temperature is within the
maximum and minimum limits.
24RWD45U - OpenAir economizer control
Main benefits Improved air quality Reduced
compressor running time Reduced wear on
compressor, condenser fan etc Reduce installation
costs 1. Additional outside air limit
thermostats not required 2. A single active
outside air sensor could be used for multiple
controllers Reduced energy consumption - Save We
can offer our customers a complete package
25Two-stage heating and cooling
26Three stage (CR)compressor - (RV)reversing valve
27RWD45U - Special applications (example)
Packaged water heat pump including supply water
control valve via 2nd independent loop X1
controls primary heat pump water temp with X3
controlling the supply water temp to the coils
Water system
28RWD45U - Special applications (example)
Rooftop or split heat pump including air quality
control via 2nd independent loop X1 controls heat
pump room temp with X3 controlling the CO2/VOC
level within room
Air / AQ
AQ processor
29RWD45U - Special applications (example)
Rooftop or split heat pump including humidifier
control via 2nd independent loop X1 controls heat
pump room temp with X3 controlling the humidifier
output to room
Air / humidity
30RWD45U - Special applications (example)
Stage control of heat pump including remote
monitoring of X1 temperature X1 controls heat
pump room temp with Y1 supplying the equivalent
signal in 0-10vdc format. Could also control
remote SP and stop/start
Air or Water
Remote display DDC PLC Alarm system Input to
another controller
31RWD for commercial applications
- RWD must be recommended for commercial
applications
- Protection against unauthorized adjustment,
equipment damage and nuisance service calls. - Optimum comfort and energy savings
- MMI should not be available for occupants
- Fan speed control should only be applied to
residential or small room applications
32RWD heat pump controllers
Thank you !
Inside a typical heat pump
Rooftop packaged unit
Indoor packaged unit